ADVERTISEMENT

ADVERTISEMENT

Record Low Voltage Electrical Bench Type 1 DWG Block for AutoCAD

ELECTRIC TENSION IN REGISTRATION FOR LOW STOOL BY TYPE 1 RULES CFE

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

of underground systems, plant register with background, floor, plant cover, cut, registration with background for, high water level, cut, registration without background for, low water level, detail, polymeric, top, detail, concrete, top, details nut frog type, on bench type, low voltage log, rule, of concretions in concrete reinforcement electrowelded mesh kpa corrugated lime. cm coating. apparent appearance inside the exterior thickness of the walls of cm. finished polished steel frame framing cm. by concrete cover with welded mesh steel frame cm. per aggregate cm. in case of being completely sealed, a piece of mm will be installed in the bottom wall to introduce the ground wire. the ground electrodes outside the register. the registers must be identified with the name of the month the first three serial number of the marks must be highlighted on any of the inner faces of the register without interfering that of the conduits of the rush with letters of cm. if the quality of the materials is checked by authorized armed laboratory, it will be verified on site. in case the records are must be inspected the lapem during your must have your notice of correspondent. Concrete cap cover detail will apply the type of install. for high level terrains with saline concrete use contain sulfate resistant compounds. the number of holes for the arrival of the pipelines in the project., Applications apply to all types of floors except. very soft soils qa kpa expansive soils. submerged soils. note: in these cases it is recommended to determine the characteristics of the soil to make the corresponding structural revision, cm. per cm. long soldiers frame on each to the center side., cm. diameter., cm. of diameter in the wall, cm. per cm. long soldiers frame on each to the center side., cm. diameter., cm. of diameter in the wall, floor, frog type, welded steel to the cover frame, hexagonal washer head, angle of galvanized steel, angle of galvanized steel, frog type, polymer cap, hexagonal washer head, details nut frog type, cap detail: cut, cm., of faith. cm. diameter., outside floor, screw details, angle steel cm., cap detail: cut, cm. of diameter in the wall, reinforcement e.m on stool f’y kpa, handle detail, in concrete bench cover, round iron cm. galvanized, mesh, use: housing cables low voltage connections in underground distribution networks up to single-wire cables for connection., isometric, reinforcement e.m on stool f’y kpa, outside floor, angle steel cm., cm., round iron cm. galvanized

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Steel
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT