Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Installations Of Gas DWG Block for AutoCAD

Gas distribution in buildings

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Symbology, curly, needle valve, dryer, Stove, Elbow from up, Bend down, Elbow, Visible pipe, Hidden pipe, Right-hand elbow, tee, Low pressure regulator, Double check valve, Globe valve, Stationary tank of lts., Heater lts., Jacketed pipe, B.t.g, S.t.g, Low gas pipe, Gas pipe rises, Crl, Rigid copper pipe type, Cfl, Flexible copper pipe type, Welded union, Crk, Rigid copper pipe type, Step valve, Reduction of, security valve, pressure gauge, Acme connection, Pool tip, living room, dinning room, kitchen, Bedroom floor, dressing room, bath, sanitary, Cto. of service, portico, Access ppal., cut, cut, cut, cut, Npt, First floor arq., Architectural plan first floor, Date: may, Location plant, Walk iztaccíhualt, scale:, Mts., north, division, north, av. Mother saw, Iztaccihualt walk, Walk iztaccíhualt, Walk iztaccíhualt, av. Mother saw, Iztaccihualt walk, Walk iztaccíhualt, Flat key., Gas installation, Jiquilpan technological institute, Architecture career, Teacher andres eloy gonzalez vega, Building site materials ii, Student mayra alejandra diaz hernandez, Gas installations in buildings should be subject to the provisions mentioned below: types of piping used which the regulation indicates are flexible rigid copper pipes type flexible copper pipes type service lines can be classified in various ways by the type of containers Fixed by the pressure that drives the low pressure high pressure by the capacity of either single-family multifamily. Multiple domestic installations supplied by a fixed tank in which no meters are used, a manual shut-off valve shall be installed in an accessible location at a point prior to the individual entrance of the pipeline to each house. Consumer appliance will be located in such a way that easy access to it its control keys. The appliances are installed inside the chosen location to locate them should allow a ventilation that prevents the environment is vitiated with the flue gases without excessive air currents that can turn off the burners. Prohibits the installation of water heaters in bedrooms, the location of such appliances shall meet the following requirements: weather shall be permanently installed in the air with adequate supports that will impede the gas water pipes. Location of the heaters must meet the following requirements: to be installed in bedroom bedrooms must be designed to dislodge the exterior combustion gases. Fixed tubing shall be connected with flexible copper bundle of length. May be connected to the hose suitable for conducting gas. P. In a state not longer than m. Of domestic stoves the installation of a flexible copper tube loop whose minimum length shall not be m. The conditions of the room of popular type make it indispensable that the domestic type stove is installed in it will be obligatory to provide permanent vents open to the exterior level of the floor level higher than the cover of the stove. Gas containers should be placed outdoors in places such as: roof gardens protected from the access of people vehicles. In buildings for room gas containers must be protected by means of cages that prevent the access of children non-maintenance personnel maintenance of the equipment containers shall be placed on a firm floor where there are no flames material pasture grass. Liquefied gas piping piping should be copper type galvanized iron comply with applicable Mexican standards will be placed visible a the height of when least on the outside in lines may be hidden in the subsoil of the yard gardens a depth of when Less m. Both cases the pipes must be painted with yellow enamel counting with signs with yellow enamel each in the connections in order to cross walls enclosed spaces must be housed inside another tube of when at least times the diameter of the tube that lodge whose ends are open to the Outside air. The gas conduction pipes must be placed when from any device conducting any pipe with high pressure corrosive fluids. Gas water heaters should be placed in rooftop yards in premises with a minimum ventilation of twenty-five changes per hour of the local air volume. Its location inside the closed premises shall be prohibited. Gas meters in room buildings will be placed in lighted places protected from high temperature shocks. Will never be placed on the tie

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Other
Measurement Units
Footprint Area
Building Features Pool, Deck / Patio, Car Parking Lot, Garden / Park
Tags , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT