Internal Housing – With Plinth DWG Detail for AutoCAD

Foundation beam for filling. – Details – specifications – sizing – Construction cuts

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

shoe box, distribution of stirrups in table of columns, within those of not splicing more than the reinforcement in the same section, distribution of stirrups in table of columns, specified in plan, specified in plan, free, passage, npt., passage, floor, neighbor floors, living room, kitchenette, dinning room, npt., passage, npt., drain, sedapal, npt., sheet, bending detail of stirrups, poor concrete screed, according to shoe box, esc., typical detail of zapata, stirrups of izage, esc., according to column table, n.f.p., beam column, covering, beam column, covering, according to picture, typical detail of anchorage of, column with running foundations, esc., n.f.p., of columns, wires, every row, according to picture, of columns, additional stirrups, stirrups, cut scale, reinforcement, soles c: h, nfp, see distribution of stirrups in table of columns, internal bend radius db, additional stirrups, splicing within the ones of not splicing more of the reinforcement in the same section, mezzanine beam, see distribution of stirrups in table of columns, beam of the last level, values ​​for less, cut rods, in case of cutting the, rods in one section, increase splice length, detail of development of, columns anchorage in shoe, specified in plan, typical detail of zapata, sole, rest see, columns, esc:, n.f.p. see plant, typical detail of zapata, sole, specified in plan, rest see, columns, n.f.p. see plant, all the shoes have concrete f’c, the level of foundation will be saved unless indicated in plan., for the foundation line see the architectural plans., foundation note, Technical specifications, stirrups, indicated in the lightened planes, minimum anchorage lengths overlapping of reinforcement, type iv of voids with percentage of voids, after the decoupling of the roof with tambourine brick., characteristics of confined masonry, technical building standards, construction design specifications, min: cm, standard lime sand, min., max cm, kg, columns beams, not exceed the, of volume, if you have alveoli these, thickness of mortar joints, mortar, maximum of empty, brick unit type iv, minimal thickness, observations, the broken walls are bearers of brick, the non-load bearing walls will raise their total height, national building regulations, design standards earthquake resistant, carrying capacity, sand sandy soils: sp sand badly graded, ground, stairs, floor, anchorage, overlaps, lightened stairs, overloads, shoes, flat beams, but pg, reinforced concrete, coatings, steel fy reinforcement, concrete f’c, concrete cycle, real estate, concrete foundations concrete cycle, but pg, ss.hh, foundation, stairs, cut, esc., n.c., npt., passage, mesh, filling, compacted, internal housing, cut, esc., n.c., mesh, filling, compacted, internal housing, esc., cut, n.c., mesh, filling, compacted, filling, compacted, esc., cut, n.c., mesh, filling, compacted, filling, compacted, stirrups, quantity, confinement both extremes, steel, confinement both extremes, dimension, column table

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel
Measurement Units
Footprint Area
Building Features
Tags , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT