Library: Installation Of Air Conditioning DWG Full Project for AutoCAD

PROJECT INSTALLATION OF INJECTION AND RETURN AIR DUCTS THROUGH A UNIT FROM A LIBRARY PACKAGE WHICH HAS TWO LEVELS, IN ADDITION TO THE SYMBOLS USED IN SAID PROJECT.

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Xxx, Xxx, fan, In one, On a concrete base of height, All the condensing units will be placed, Expansion tank, Multiple condenser unit, Variable volume box, Ucm, Tex, Ccv, Cvv, Gdr series. Size indicated., C.c.v. Size indicated., Grille of injection mca. Tuttle bailey mod., Mod me vias c.c.v. Size indicated., Diffuser of injection mca. Tuttle bailey, Extraction grid mca. Tuttle bailey, With registration hinge indicated size., Return grid mca. Tuttle bailey mod., Mca. Tuttle bailey mod. Pv. Neck indicated., Modular roadway diffuser, Mod me vias c.c.v. Size indicated., Diffuser of injection mca. Tuttle bailey, C.c.v. Size indicated., Volume control gate, Return grid mca. Tuttle bailey mod., Grille of passage in door mca. Tuttle bailey, Air intake grille mca. Tuttle bailey, Mod. C.c.v. Indicated size, Mod. C.c.v. Size indicated., In millimeters., Flexible couplings in, Of at least four, The computers that connect., For the connection equipment chillers towers, blueprints, Equipment box, Are given in inches., The dimensions of the pipes are given, See general installation details in, The measures of diffuser grids, For equipment models see plan of, Stainless steel caliber, Diagram of control diagram., Of anticorrosive paint., The extractions of fatty fumes will be of, For all sizes with one hand, Black caliper with welded joints, The refrigerant pipes will be of copper type, Only the gas refrigerant piping should be insulated., See thermostat model mark in, Must be installed on the inner side of the duct, Thermal insulation type duct liner thick, size, Slots, number of, Dli, of box, number of, Slots, Dlr, Linear diffuser, Of slots, separation, Of injection, Linear diffuser, return, Of slots, separation, temperature sensor, Return of ice water, Ice water supply, Hot water supply, Aah, Rah, Aaca, Air release valve, Butterfly valve, gate valve, Multipurpose valve, filter, Swinging valve, Antivibration seal, valve, flexible hose, Suction diffuser, Aac, Rac, Vmp, Vbp, Vma, Race, Hot water return, Air separator, Up the injection line., Return duct., Extraction duct., Low injection duct., Low return duct., Low extraction duct., Car model According to the following nomenclature., Linear diffuser for injection mca tuttle bailey, Linear return diffuser mca tuttle bailey, Model caa. According to the following nomenclature., Butterfly valve with actuator, Hot water supply pipe, Hot water return pipe, Return water condensate, Condensate water supply, Cold water return pipe, Insulated flexible duct, Galvanized sheet duct, Of thickness indicated size, Ice water supply pipe, Accessories to avoid the installation of anti-vibration joints., The couplings should be installed as close as possible to, The steam extraction air ducts, For lavalosa must be constructed of sheet of, Fc air intake ducts in rooms, Ugah, Ice water generating unit, Ice water pump, Bah, roof, Bac, Hot water pump, Condensate water pump, Cooling tower, One, air-handling unit, Ventilation unit, Evaporator unit, Fan and coil unit, via, See, Air blower fan, Air extraction fan, Ula, Air washer unit, water heater, Aas, Ras, Brackish water return, Brackish water feeding, ball valve, Vbo, Pipes for drainage, Modular return grille of, Cubes by, The drains will be for others., Air expenses are given in pcm, On the outer face of the duct with insulation of, The internal air-conditioning ducts will be isolated, Fiberglass foil pipelines abroad, condensing unit, Ure, Energy recovery unit, Water source, heat exchanger, All dimensions of the ducts are interior., The full camera will be by contractor shall, Be perfectly sealed., by, The water costs are given in gpm, The dimensions of the equipment are subject to the mark, That certified plans of the same are installed., Will be with weather protection., Of panels for the proper placement of, Architectural plans should be reviewed, Air conditioning installation ventilation, These plans only serve as a reference for the, Diffuser grids., Smoked canvas collar, Specification no., kind, Drainage, Drainage, galvanized, steel pipe, everybody, Hydraulic pvc, everybody, Selective material box, fluid, frozen water, do not., specification, kind, material, Minors, diameter, pipeline, Mm., thick

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Full Project
Category
Additional Screenshots



File Type dwg
Materials Concrete, Glass, Steel, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , ,