Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Pumphouse DWG Detail for AutoCAD

Details – specifications – sizing – Construction cuts

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

inner reinforcement, h any, valuesdem, column stirrups, beam abutments, beam girder column, hook, length, bar, bottom, top, top bar, bottom bar, no scale, development length, flat, steel interior, splice over the supports, b.- in case of not splicing, in the areas indicated or with, c.- for lightened and beams, a.- no more splicing of the, note, same section, increase the length of, the specified percentages , consult the designer., being the length of joint, column of confinement, – compression masonry:, – solid brick kk clay :, – specific weight masonry:, false floor, sobrecimientos, technical specifications, – unit: bricks king kong de clay, girders, confinement columns, – iron joints, structural columns, footings, made on site, concrete shelving, longitudinal cut window grille booth pump, shaft, point of sun dadura, frame faith, with silicone, sealed gasket, exterior, interior, window grille vm, mobile anchor, frame of faith, window grating, welding, electric, cross section, point of, ceiling projection, pumping house, floor: cement , sidewalk, roof plane, pumping house, roof projection, plant, building projection, ridge, cement, door, metal, slope, perimeter, covered with plate, wavy thermoacoustic, with pvc lining, ceiling exterior, with grating, metal window, ridge plate, thermoacoustic, wavy thermoacoustic, side enclosure, with wood, drainage channel, rainwater, contrazocalo, cc cut, top main flange, red color, diagonal brace, evacuation chute , prefabricated plastic, ceilings with material, corrugated iron, vertical brace, belts, burnished, finishing table, environments, finishes, metal windows with external grills, floors, polished and burnished cement, lightweight, planc has thermoacoustic, shed, exterior, rubbed plaster, grout, columns, and beams, plaster rubbed and ironed, walls, clothing, ceilings, carpentry, wood, roof, roof, metal, latex type I interior walls, paintings, metal doors with ang. profiles, latex type i exterior walls, type I latex beams and columns, type I latex parapets, varnished wood carpentry, sand cement proportion: brick walls, m-type mortar with joint thickness, grade, columas de Mooring will be emptied, after having raised the walls, jagged brick., window, type, cant., size, observations, width, height, alfeizer, sliding, lattice, row, p. enamel, one sheet, double sheet, p. varnish, metal, door and window panel, note: the measurement of the alfeizer is being taken from the finished floor level., interspersed, lower main flange, metal brackets, on both sides, ref., detail of trusses, foundations, with own material, compacted filling, masonry wall, brick, columns:, footings:, floor, lightened, wooden truss, axis a, b, section aa, beam, detail of anchors, beams with columns, reinforcement in one section, of column or support, joints of the reinforcement, joints, slabs and beams will not be allowed, in columns, in slabs and beams, steel, abutment, table of columns, i.- type of foundation: run, summary of foundation conditions , ii.- foundation support layer: silty clay, iii.- design parameters for the foundation :, – differential settlement: -cm, iv.- aggressiveness of the soil to the foundation :, does not exist, use type ip cement, v.- additional recommendations: see soil study, specific reinforced concrete, portaland concrete type ip, – concrete in contact with the ground, note:, the aggregates of the concrete must comply with the requirement of design of mixtures and laboratory tests, that can be produced with them a concrete of the, national of buildings in force to date., unit of masonry: specifications of masonry, all units of wall masonry will be manufactured, – mortar:, will be used for the settlement of masonry units, and will be made up of a mixture whose proportions , in volume are the following, – a part of cement, – four parts of sand, with the minimum dimensions indicated in this plan, will be, of concrete., – thickness of the joints :, – tests :, the tests will be made of compliance with the provisions of the current national building regulations., -tabiqueria :, with mortar of :, – five parts of sand, type of wood :, specifications of structural wood, studies must be supplemented with tests of soil mechanics, in order to determine the characteristics of the foundation soil, these in the wood to be used must not present any of the following defects :, twists, flakes, cracks or knots in the third, central, must comply with the classification standards, for made

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Plastic, Steel, Wood, Other
Measurement Units Imperial
Footprint Area
Building Features
Tags , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT