Excel calculation memory for the dimensioning of a potable water system reservoir. The spreadsheet provides automated formulas for determining reservoir regulation volume based on population demand, supply hours, and peak hourly flow. It includes specific sections for calculating operation volumes, minimum water levels, and pipe diameters for PVC distribution.
The file features geometric dimensioning for a domed cylindrical storage tank, calculating total height, diameter, and freeboard. Technical parameters covered include average daily demand, peak demand coefficients, and Manning’s coefficient for flow calculations. Memoria de cálculo para dimensionamiento de reservorio.