Register Ascending Flow Anaerobic DWG Block for AutoCAD

Beds; booth and download

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

plant, Esc., Pipe pead cm, Elev, Elev, Stainless steel screw, The steel plate will be separated from the toothed spout cm secured with stainless steel screws, No. Cm, No. Cm in two directions, cross-section, The location of the as well as the determination of the levels of operation, The bolts to fasten the triangular spout the vertodor, The minimum coating of steel for elements in contact with ground water shall be, The height of the structure will be set according to the depth of the arrival, Are the responsibility of ing. Building resident, Primary two alquidalic enamel hands., The structural concrete will be, Dimensions except those indicated in another unit., Cm, Notes:, All metal parts must have a one-handed base protection., gate valve, Spherical in diameter, Sludge bed, Fine sand bed, Record of, Reinforced concrete slab, unity, population, Vol. Of sludge generated, concept, Project data, quantity, Hab, Of cm d.d., Of rafa, Minimum cm, Cm, Pvc pipe, Fume pipe, We present the case of two beds for the other two cases will follow the same scheme, The sludge will be removed from the rafa by gravity when the terrain topography, Of the level of operation of the rafa, Allow for pumping when the level of the drying beds is above, Detail of sludge arrival, Proportional will be stainless steel, plant, Drying bed, Drying lime, Sludge arrival line, Coming from the rafa, Towards the carcamo, Castle of no. Stirrups of cm, Spherical, diameter, gate valve, Spherical, diameter, Record of, Fine sand, Sludge bed, Minimum freeboard, Minimum cm, Chain of closure with four of no. Cm, Sludge bed, input, endowment, Lps, Sludge density, Vol. Of sludge, Vol. Every month, Quantities of work sludge drying bed, concept, Cleaning stroke, concrete, Wood frame, reinforcing steel, excavation, filling, quantity, unity, Red wall wall, Flat mortar, pumping, Concrete slab, Reg., H. Town hall, Tetela de pue., Tetela de ocampo, the mayor, Location:, Plan no., Of the municipality of tetela de ocampo, draft:, Integral sanitation, Ing. A. Uribe peña, firm:, scale:, calculation:, I raise:, drawing:, Director of public works, C. David garcia carmona, sanitation, flat, Sludge drying bed, entry, Pead tube of cm, departure, Castle of no. Stirrups of cm, Fine sand bed, Record of, Castle of no. Stirrups of cm, Chain of closure with four of no. Cm, Spherical compression valve of cm, Fine sand bed, Record of, Sludge bed, Fine sand bed, Record of, Sludge bed, No. Cm in two directions, Free board, No. Cm in two directions, Elev, Elev, discharge, plant, Flouted, Esc., Masonry, Cement mortar, Slope according to angle, Simple concrete, Resting material, By the resident, Indicated depth, Elevation of natural terrain, Esc., cut, Esc., arrival, entry, Pead tube of cm, departure, Pead tube of cm, departure, Drying bed, Drying lime, Castle of no. Stirrups of cm, Sludge arrival line, Coming from the rafa, Cm fume tube, Spherical compression valve of cm, Pead tube of cm, Spherical compression valve of cm, Castle of no. Stirrups of cm, Towards the lagoon, structural, Esc., Drying bed, Drying lime, Castle of no. Stirrups of cm, Chain of no. Stirrups of cm, Strings of no. Stirrups of cm, Castle of no. Stirrups of cm, Cm in two directions, profile, Horizontal scale, Vertical scale, Elev, Cm fume tube, Chain of no. Stirrups of cm, cut, Esc., Fine sand bed, Record of, Fine sand bed, Record of, Sludge bed, Cm, Concrete slab, departure, Towards the lagoon, entry, Chain of no. Stirrups of cm, Fine sand bed, Record of, Sludge bed, Cm, Concrete slab, Cm spherical gate valve, Fine sand bed, Record of, Sludge bed, Cm, Concrete slab, No. Cm in two directions, Free board, Cm spherical gate valve, Cm fume tube, Pvc pipe cm, Pead tube of cm, Cm spherical gate valve, No. Cm in two directions, The structures will be deployed on a concrete template, The concrete used will be of, The reinforcing steel will be a fy, No overlap will be allowed on the steel on a single axis., Dimensions in centimeters except those indicated in another unit., All metal parts must be protected against corrosion., The concrete must have integral waterproofing., The minimum steel coating shall be cm., The concrete used

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel, Wood, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT