ADVERTISEMENT

ADVERTISEMENT

Installation Detail In Ceiling Light Spot DWG Detail for AutoCAD

Detail Installation in Reticular Plafon Multivoltaje Airship. Axonometric

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

detail, bollard, xxxxx, post, prefabricated register, pipe register, detail sleeve record to each, groundig system cadweld type details., cu. wire, with blind cover, with cover, structure, structure, detail connection of conductive tile, conductive tile to ground connection detail, channeling with, ground connection, cadweld connection, cadweld connection, cable cu., gruond connection, column, column , connection detail, connection detail, copperweld rod, copperweld rod, ground rod, sleeve detail register to, each ground rod, cover for register, register, cover for, for conductive tile must to do the same conection in second level., indicate in the drawing and is interconnected to the ground mesh of the, the surrounding ring grounding the structural of the biulding as is, the ground electrode is provided with a plastic sleeve with cap to allow, details of the system of lands type cadweld., all earth electrodes so indicated, they will have plastic sleeve with lid that makes them, the whole conductor of this system will go directly buried in the ground, in the plane and will be interconnected to the earth grid of the sub-station The surrounding ring will land the structure of the building as indicated, all connection will be exothermics cadweld type., for conductive tile to make the same connections in the upper floor., any way., electrical substation., electric., in no time. , future maintenace for testing and metering., recordable for measurements and future maintenance tests., all connections should be exothermic type cadweld., notes, notes, copper lamiina, cooper plate, copper foil for landing conductive tile connected to structure through, conection point exotermic, cadweld type., connection point type cadweld., register., simbology, simbology, to pipe, to tube, slotted cover, slotted cover, electrolytic electrode, lyncole xit grounding, soil, terrain, finished grade , floor finished, lynconite backfill, linconite filling, ul name plate, weep holes, drainage hole, protective cover, protective record, breather hole, vent hole, data plate, unscaled, maintenace fo r testing and metering., make them recordable for measurements and future maintenance tests., All ground electrode is provided with a plastic sleeve with cap to allow future, all the driver of this system will go directly buried in the floor, in the plane and will be interconnected to the earth grid of each transformer, the drawing and is interconnected to the ground mesh of each transformer, the surrounding ring grounding the structural of the biulding as is indicate in, same as above but without register., electrolytic electrode for grounding system pipe type with mineral salts, lyncole, electrolytic tubular earth electrode with mineral salts in its interior, similar to the previous one but without registration, drowned and hidden in the floor., backfill., lightning system protection., and lightning rod system ., record detail for rod, ground copperweld type., connector for ground rod, and connected to the mesh of the electric sub station grounds, the surround ing ring will land the building structure as indicated on the drawing, all connections must be exothermic type cadweld., all ground electrodes will have plastic sleeve with cap to make them, registable for measurements and future maintenance tests., all driver of this system will be directly buried in the floor, all ground electrodes, have plastic sleeve with lid that makes them, type ‘a’ light fixture., type ‘b’ light fixture., type ‘c’ light fixture., type ‘d’ light fixture., circuit controlled by photocell., connect cable to column by exothermic weld., ground system test., electrical notes, lithonia, wall, surface, recessed, if, electronic ballast., ballast., double fusing and wet location listing. , corrosion resistant die cast aluminum housing ,, high pressure sodium cutoff lens, dark bronze finish, fluorescent surface mounted wrap around, fixture with acrylic prismatic diffuser, same as fixture type ‘e’ except with emergency, hps wall pack with glass refractor , dark bornze ,, recessed incandescent downlight with black, no., fixt., hor, hps wall pack with glass refractor, dark bronze finish,, hps wall pack with glass refractor, dark bronze finish, corrosion resistant die cast aluminum housing., housing. double fusing and wet location listing., recessed metal halide downlight with black, location listing., lighting fixture schedule, manufacturer, catalog no., physical, dimension, mounting, lamps, watts, type, volts, propagation of the flame. low emission of fumes., metal with connection to compression., flexible metal pipes., cables: monterrey or condumex conductors ,, switches: square-d or cutler-hammer., boards: square-d or cutler-hammer ,, dampers: leviton or arrow-hart ,, contacts: leviton or arrow-hart ,, luminaires: lithonia or cooper lighting ,, pipes: jupiter or rawelt ,, acc

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Aluminum, Glass, Plastic, Steel, Other, N/A
Measurement Units Metric
Footprint Area
Building Features
Tags , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply