Post Details; Luminaire Connections DWG Detail for AutoCAD
Details of post; bollard; Luminaire connection; Box inspection of electric rod
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
unscaled, Direct burial sched. Pvc conduit min. Pvc pipeline cedula of min.directly buried., Number of spaces between conduit and number of conduits. Number of center spaces of the pipes is not the number of pipes., Notes: notes, Provide rebar in each corner and add an additional rebar centered between each additional pair of conduits. For each of them to supply steel in each corner add an additional in the center of each pair of by, Number of spaces between conduit and number of conduits. Number of center spaces of the pipes is not the number of pipes., Designer notes: designer notes:, Provide rebar in each corner and add an additional rebar centered between each additional pair of conduits. For each of them to supply steel in each corner add an additional in the center of each pair of by, Conduit size pipe size, Panelboard ‘elp’ branch circuit number panelboard ‘elp’ number of the typical branch circuit., Circuit breaker typical thermomagnetic switch, Automated lighting control panel automated lighting control panel, Volt tipico luminaires, note:, Refer to for sitelighting circuit numbers. Refer to the page for the numbers of the circuits of the external illumination., Driver feed to walkway fixtures feed with cable for road lamps., Driver feed to roadway fixtures with cable for street lamps., Min, Red wide thousand plastic warning tape to read red line of wide thousand. Precautionary plastic tape to be read telecommunications., The material to be compacted must be free of stones other material., Schedule pvc conduit size as indicated on plan drawing. Pvc pipe cedula of the size that is seen in the planes., Min cover over rebar or wire mesh, Rebar o.c. Or gauge wire mesh each face steel o.c., Rebar continuous at each corner, Earth, Grade level, Round round, For pole base anchor bolts spacing see mfr’s data detail for post base with screws spacing recommended by manufacturers., High bollard walkway height fixture for bollards outdoor road lamps., Pole ground lug to green ground pole landing rod connected green., Grounding type connect to ground wire. Landing on pipe nozzle connected with ground wire, Finish grade, Anchor bolts as directed by mfr. Requires anchor bolts as mfr says., Adapter or bushing if direct burial adapter if the cable is directly buried, Rigid steel conduit min. Stl rigid pipe min., Concrete base s, Note: refer to for condition at pavers and finish grade elevations. Refer to exterior finishes in pavement finished for levels., Pole pole, Hand box, Pole base see mfr’s data for details base for poles see mfr’s for details., Adapter or bushing if direct burial cable adapter if the cable is directly buried, Rigid stl cdt. Min. Stl rigid pipe min., O.c., day., Concrete base in hole. Placed on undisturbed earth or compacted backfill hollow for concrete base located in a place where it does not affect with packed filling, Depth below grade, Anchor bolts in accordance with manufacturer’s recommendation anchor bolts of agreement manufacturer’s recommendations, Vertical equally spaced equally spaced vertical steel., Maximum pole height, Pole base chart, Up to feet up feet, Leveling leveling nut, Clearance space u.o.n., Grout min., Clearance spacing, Chamfer inclined profile, Direct burial sched. Pvc conduit min. Pvc pipeline cedula of min.directly buried., Grounding type conduit bushings type of landing for pipeline connectors, Provide base above grade elevation if located in paved parking areas or other areas subject to vehicular damage. Provide base above floor level if located in paved parking areas other areas subject to vehicle damage. Bond ground rod conduit and branch circuit ground conductor to pole ground lug. Ground the cable of the ground rod accessory of the pipe if it is metal the conductor of the ground branch circuit that comes from the distribution board. Coordinate with pole manufacturer’s recommendations coordinate with pole manufacturers recommendations. Use base for bollards and base for poles. Use in base for bollards in base for poles., Depth below grade, Ground, Min, Cover marked the cover must be marked with the word, Pull slot channels to pull., Cover cover day., Top of cover to be flush with grade, Crushed stone, Note no
Raw text data extracted from CAD file:
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
unscaled, Direct burial sched. Pvc conduit min. Pvc pipe cedula of min.directly buried., Number of spaces between conduit and number of conduits. Number of center spaces of the pipes is not the number of pipes., Notes: notes, Provide rebar in each corner and add an additional rebar centered between each additional pair of conduits. For each of them to provide steel in each corner add an additional in the center of each pair of by, Number of spaces between conduit and number of conduits. Number of center spaces of the pipes is not the number of pipes., Designer notes: designer notes:, Provide rebar in each corner and add an additional rebar centered between each additional pair of conduits. For each of them to provide steel in each corner add an additional in the center of each pair of by, Conduit size pipe size, Panelboard ‘elp’ branch circuit number panelboard ‘elp’ number of the typical branch circuit., Circuit breaker typical thermomagnetic switch, Automated lighting control panel automated lighting control panel, Volt tipico luminaires, note:, Refer to for sitelighting circuit numbers. Refer to the page for the numbers of the circuits of the exterior illumination., Driver feed to walkway fixtures feed with cable for road lamps., Driver feed to roadway fixtures feed with cable for street lamps., Min, Red wide thousand plastic warning tape to read red line of thousand. Plastic tape of precaution that is read telecommunications., To be free of all rock and foriegn material when compacting the fill must be free of stones other material., Schedule pvc conduit size as indicated on plan drawing. Pvc pipe cedula of the size that is seen in the planes., Min cover over rebar or wire mesh, Rebar o.c. Or gauge wire mesh each face steel o.c., Rebar continuous at each corner, Earth, Grade level, Round round, For pole base anchor bolts spacing see mfr’s data detail for post base with screws spacing recommended by manufacturers., High bollard walkway height fixture for bollards outdoor road lamps., Pole ground lug to green ground pole landing rod connected green., Grounding type connect to ground wire. Landing on pipe nozzle connected with ground wire, Finish grade, Anchor bolts as directed by mfr. Requires anchor screws as mfr says., Adapter or bushing if direct burial adapter if the cable is directly buried, Rigid steel conduit min. Stl rigid pipe min., Concrete base, Note: refer to for condition at pavers and finish grade elevations. Refer to exterior finishes in pavement finished for levels., Pole pole, Hand box, Pole base see mfr’s data for details base for posts see mfr’s for details., Adapter or bushing if direct burial cable adapter if the cable is directly buried, Rigid stl cdt. Min. Stl rigid pipe min., O.c., day., Concrete base in hole. Placed on undisturbed earth or compacted backfill hollow for concrete base located in a place where it does not affect with compacted filler, Depth below grade, Anchor bolts in accordance with manufacturer’s recommendation anchor bolts of agreement manufacturer’s recommendations, Vertical equally spaced equally spaced vertical steel., Maximum pole height, Pole base chart, Up to feet up to feet, Leveling leveling nut, Clearance space u.o.n., Grout min., Clearance spacing, Chamfer inclined profile, Direct burial sched. Pvc conduit min. Pvc pipe cedula of min.directly buried., Grounding type conduit bushings type of landing for pipe connectors, Ground level elevation if located in paved parking areas or other areas subject to vehicular damage. Provide base above floor level if located in paved parking areas other areas subject to vehicle damage. Conductor ground pole conductor ground pole. Ground the cable of the earth rod accessory of the pipe if it is metal the conductor of the ground branch circuit that comes from the distribution board. Coordinate with pole manufacturer’s recommendations coordinate with pole manufacturers recommendations. Use base for bollards and base for poles. Use in base for bollards in base for poles., Depth below grade, Ground, Min, Cover marked the cover must be marked with the word, Pull slot channels to pull., Cover cover day., Top of cover to be flush with grade, Crushed stone, Note: no
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Detail |
Category | Water Sewage & Electricity Infrastructure |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Plastic, Steel, Other |
Measurement Units | |
Footprint Area | |
Building Features | Car Parking Lot, Garden / Park |
Tags | autocad, bollard, box, connection, connections, DETAIL, details, DWG, electric, electrical installation, grounding, haute tension, hochspannung, inspection, kläranlage, luminaire, post, rod, Street lighting, treatment plant, wiring |