SYSTEMS STARTS OF 19, 25 AND 38 mm UNDERGROUND COPPER TUBING (by Chilean standards, including required health services logo in V Region of Valparaiso)

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

max. note, sector pipeline connection of the distribution network, sector change of address, start pipe sector, turnkey sector, meter sector, wall foundation, according to nch, official line, sectorization start-up system, official line, max. note, official line, sectorization start-up system, meter sector, size of the meter depending on the maximum flow rate, start, component, size main components in inches, matrix, bed of coarse gravel, start-up with, see plans:, see note, to the. coppermade, Format, material, ptoc, start-up systems, quantity, description, date, firm, draft, modif., date, drawing, firm, first name, approved, connector just ri crazy, python nut, normative references, reemp. by:, dimensional, unity, scale, reemp. to:, nch, nch ft esval, with copper tubing., to the. coppermade, Format, material, quantity, description, date, firm, draft, modif., date, drawing, firm, first name, approved, pipeline, variable, copper, reemp. by:, dimensional, unity, scale, reemp. to:, nch, to the. coppermade, magnetic meter class B., nch, ball type key re., to the. coppermade, nch ft esval, to the. coppermade, python nut, nch, to the. coppermade, connector just ri crazy, to the. coppermade, terminal, nch, main changes, main changes, correct meter position, concrete base of, ptoc, nch ft esval, Underground., see note, sea.’, sea.’, esval, modif., ptoc, update according to nch, sea.’, sidewalk, esc., cut, esc., see note, concrete kg., fiscal brick, elevation, profile, cover of frame, steel, ptoc plan, masonry, camera, the option of underground meter must be validated according to the particular conditions of the esval s.a .. can only be installed in sectors that have pavement green areas. the user’s garden key must be installed continuation of the indoor water tap. the threaded ends of the meter must be differentiated for the meters according to nch for starting systems in public gardens squares can also be used the cover frame of plane ptoc only in this the cover must be secured with a lock of the type shackle according to plane type ptoc for component it is accepted as alternative of solution the use of a stopcock of seat. to connect with the upstream copper pipe an American union must be used. for longer lengths this acceptance must be subject of study approval by the competent authority. the pipe in contact with aggressive soils should be protected with the installation of a river bed of cm cm on each side of it. The above is not necessary at road crossings. inspection test: it must comply with what is established in the nch without prejudice to what is indicated in the technical standard esval oc, Notes:, ptoc plan, seat valve, start up, after the meter, american union only, to. coppermade, nch, key of passage ri, to the. coppermade, nch: ft esva

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel
Measurement Units
Footprint Area
Building Features Garden / Park
Tags , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT