Hydraulics And Fire Safety Condominium DWG Detail for AutoCAD

Details of facilities of water and fire system in Guatemala condominium. Construction details – schemes

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Sanitary sewer systems, Plant set, Rainwater installations, Plant set, Schematic treatment plant operation, Of aerobic type in the extended aeration mode of sludge with a purifying efficiency of up to that of the control of the plant as the automation is through a micro plc system that allows to carry out the control in case of two teams to alternate with Control lights as well as fault lights control grille channel start cycles which retains larger sediments not commonly retains fatty acids commonly lower density than the treatment, Reactor where oxygen is supplied to form the matter with the purpose of obtaining the decantation in which sediments are produced from the aerobic process by the heterotrophic bacteria in a digester tank in which the excess is produced from the production of lareaction where Is stabilized by consumption tank where hypochlorite is dosed destruction, Details of pluvial water drainage, drinking water, Water details storm drains, Plant set, Furnished architecture, Plant set, Esc, Area for first building, Topographic phase plane, Esc, Section, section, topographic map, Phase lots buildings, Phase lots, phase, Topographic phase plane, Esc, Terraced house santa fe, Valve installation detail, For the distribution network of, Mechanical joint with, Anchor mca. Eeaa iron series, Pv., simple, Concrete dock, drinking water., the bell., the top of, Minimum between the pipe, Leave it light, Valve body., Between the concrete base the, Keep at least cm. Of course, Concrete ring, Anchor mca. Eeaa iron series, Mechanical joint with, Pv., Mueller model, With ends for mechanical joint., Awwa brand gate valve, Cast iron ruiz brand, Valve, Bell of operation of, kind of, Pvc pipe awwa, class, Pvc pipe awwa, Concrete ring, Meter box, plant, Plant view esc., Facade esc., Chlorination pumping equipment control box, distribution network, Tank distribution comes, pipeline, Ang. iron, Expansion tank, Press, Switch, Reg. Pressure, valve, filter, Unit check reg, empty, Vent, Chlorinator, evaporator, Symbology, Pipe of, Spike reduction, Length of section in meters, Expenditure in liters per second, General plant of potable water distribution network, living place, Wicket, living place, Pvc., Step valve, Club house, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, Hydrant outlet, Step valve, Hydrant outlet, Distribution tanks, Hydrant outlet, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, living place, Pvc of, suction, Pvc., living place, living place, living place, living place, water well, Fourth pumps, Pvc of, Home water supply, population, green area, , Project population, Coefficient of daily variation, Coefficient of time variation, Capacity of regularization of two tanks, Project data:, Relation of population project expenses, Additional appropriation, Building area, Capacity of two tanks, distribution, driving, Search by photos:, area, Lotified, Fire volume, Volume for repair, Total storage volume, Average daily volume, daily., Max expenditure, Average expenditure, schedule, Max expenditure, By pumping, Four meters, square meter, Meters, cubic meters, Meters, Equivalent pump flow gpm., Minimum pipe diameter, Hp pump power speed, section, Pipe in streets streets, Pend. variable, Potable water pipe, Mm. Pvc, sidewalk, Pend. variable, sidewalk, Symbology, Pipe of, Length of section in meters, Expenditure in liters per second, Fire network in the form of an extension, Branch number of houses number of houses number of houses section number of houses section number of houses total extension houses, Total note number of lots faucets in green areas other connections maximum consumption time value used for the calculation of the distribution line, Pipe of, Lps, Lps, Upper slab, concrete, bed, both senses, central, both senses, Perime protection

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Concrete, Plastic, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply