Fire Resistant Pipe Supports And Clamps, With Load Table And Distances DWG Block for AutoCAD

Different types of clamps and pipe for supports protection vs. fire load table includes maximum and maximum distances between them.

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Steel beam, Eq ear connection, Maximum seismic bearing distance, Anti-seismic support, Pipe or, If not, Over, If not over, Pipe or l’s, Support angle, clamp, Important:, Support arm, pipeline, Grinnell, Full support, Anti-seismic support, clamp, Eq ear, Support arm, Tub., Tub., Support arm, Anti-seismic support, Maximum sisimic support distance, Support angle, Eq ear connection, Solid wood beam, Clamp fig., Pipe grinnell, Bra, structure, Fig., light, Maximum distance between supports, And smaller, Pipe diameter, Ced, Diameter rod, Washers, A.t., Support arm, Connection to, End only fig., length, pipelines, length, pipelines, Trapezoid mount, length, dipstick, dipstick, dipstick, dipstick, dipstick, dipstick, Pipe clamp, pipeline, Suspended trapezoid, Riser clamp, discontinued, pipeline, Strut brace, Clamp-on, Strap with retainer, Retainer strap, Pear mount, Threaded rod, with, Fixed nut, Threaded rod, Hex nut, Flat washer, Threaded rod, Pear-type stake, Angle by, Suspended bolt type, Threaded bolt type, Hex nut, angle, Clamp with bolt, Nut assembly., Riser clamp, Side beam support, suspension, Pear mount, Lateral support, cap screw, Flat washer, Hexagonal hinge, Pipe support, Eye bra, Type support, cap screw, Fig, Steel bracket, Steel angle, Soldier spot, With bolt, angle, With bolt, Threaded end, Pear mount, Cplg, Type support, Powered by motor, Suspended stud, Pipe clamp, Threaded at the end, cap screw, Threaded rod, Powered by motor, specific, Suspended insert, Pear mount, angle, Threaded rod, Threaded plate, Insert, concrete, Pear mount, Insert, Suspended flange, Ceiling, Pear mount, Threaded, dipstick, Bra, flange, Ceiling in, specific, Cover fill, steel, Cplg, Plate, Pear mount, Threaded rod, concrete, Structural norm, Specifically perforated, Suspended anchor, Just under, Permission published, Of engineering, Anchor in, Rod, use, eye, discontinued, Pear mount, Threaded rod, On deck, Concrete fill, Structural norm, Just under, Permission published, Of engineering, use, pear, Perforated chain belt are allowed., The change of direction in each valve connected equipment., Which is not the building structure., A suspension will generally be used one foot of each, Do not support the pipeline of the other channel other equipment, Shall be used to maintain the position with respect to the beam where, The following suspensions are not acceptable allowed:, A clamp will have locking nuts set screws. a, The lid is suspended in a structural manner. The retention straps, Upper clamp flange will be used when attaching a rod, Of the circular cross section. Use the adjustment of the, Fixing nuts in the suspension accessories. any, The suspension will be threaded in both continuous threaded, Require The retention straps will be used in the pipe of the, Hanging suspender suspensions, Will be in agreement with the tables shown in fm lpds, The close spacing of the structural boundary., Where the concentrated loads are building, The maximum allowable distance for pipe suspensions, You must receive approval before you install it., Accessory assemblies of the, In situations where approved accessories can not be used, Slabs using approved structural fittings, Pipe installation the system will be supported by, When installing tubing in steel of the clamp style, The beam clamps will be used from where it will be, All anti-seismic support will be in agreement with, According to the lpds of, All tubing support sockets will be fabricated, On deck without reinforcing it from the roof metal., Of e.q. For the systems of, Will be selected based on the load that will be supported., important:, Suspensions located in beams., Part number size, Conditions of if need use the other, Suspensions Steel Pipe Aids, The arrangement will be submitted, Of conformity with, Use the figures shown in this in accordance with, All materials will be designed manufactured within, Tolco similar factory is accepted, Use only the materials of the approval of the, In the piece for your same identification., Maintain the angle for supports., All anti-seismic support will be in agreement with, If the maximum length is more than specified above, angle of, Horizontal load, Use the following support on the pipe, length, Maximum, support for, Maximum, Maximum horizontal loads for anti -ismals, Diam, Horizontal load, Maximum, length, Max

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots Missing Attachment
File Type dwg
Materials Concrete, Steel, Wood, Other
Measurement Units
Footprint Area
Building Features Deck / Patio, Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT