ADVERTISEMENT

ADVERTISEMENT

Detail Average Voltage Structures DWG Plan for AutoCAD

Details of structures of medium voltage distribution; SIGET armed with poles under standard isometric view; plan and side; They may be useful in developing a draft medium voltage

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Label number, Detail of structures according to standard siget, plant, Isometrico., frontal, Isometrico., frontal., Description of materials, description, Complete clamp, Tw copper wire, Led, For mercury vapor lamp, Photocell, Led install, Machine bolt, Complete: includes only bolts of the ends in greater pole to use bodywork bolt the metal part of any luminaire installed on concrete poles, earth must be connected to a point with earth reference., observations:, Installation of mercury vapor luminaire, structure:, quantity, Compression connector, Description of materials, description, Complete clamp, Ansi type reel insulation, machine, machine, Preformed shot, Complete: Includes only end bolts, Pushed secondary cut, structure:, quantity, Stirrup for reel, Description of materials, description, Complete clamp, Ansi type reel insulation, machine, machine, Preformed shot, Complete: includes only end bolts for the material required in the anchor to see the respective standard., Secondary auction, structure:, quantity, Round, plant, frontal, Stirrup for reel, frontal, Description of materials, description, Complete clamp, Expansion anchor, Galvanized steel, Complete: includes only end bolts the cable of the retainer will be of galvanized steel extra hight strength for the material required in the anchor to see the respective standard., Simple secondary anchor, structure:, quantity, Round, Anchor rod, Support wind ring, Preformed shot, Ascr, machine, Compression connector, Isometrico., Description of materials, description, Complete clamp, Ansi type reel insulation, machine, machine, Preformed shot, Complete: includes only end bolts for the material required in the anchor to see the respective standard., Double cross-over, structure:, quantity, Round, plant, frontal, Stirrup for reel, Metal post, Metal post, Metal post, Metal foot post, Dimensions in meters, Simple secondary anchor, Dimensions in meters, Pushed secondary cut, Dimensions in meters, Double cross-over, Secondary auction, Led lamp installation, Isometric

Raw text data extracted from CAD file:

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Label number, Detail of structures according to standard siget, plant, Isometrico., frontal, Isometrico., frontal., Material description, description, Complete clamp, Tw copper wire, Led, For mercury vapor lamp, Photocell, Led install, Machine bolt, Complete: includes only bolts of the ends in greater pole to use bodywork bolt the metal part of any luminaire installed on concrete poles, earth must be connected at a point with earth reference., observations:, Installation of mercury vapor luminaire, structure:, quantity, Compression connector, Material description, description, Complete clamp, Ansi type reel insulation, machine, machine, Preformed shot, Complete: Includes only end bolts, Pushed secondary cut, structure:, quantity, Stirrup for reel, Material description, description, Complete clamp, Ansi type reel insulation, machine, machine, Preformed shot, Complete: includes only end bolts for the material required in the anchor to see the respective standard., Secondary backtack, structure:, quantity, Round, plant, frontal, Stirrup for reel, frontal, Material description, description, Complete clamp, Expansion anchor, Galvanized steel, Complete: includes only end bolts the cable of the retainer will be of galvanized steel extra hight strength for the material required in the anchorage to see the respective standard., Simple secondary anchor, structure:, quantity, Round, Anchor rod, Wind clamp support, Preformed shot, Ascr, machine, Compression connector, Isometrico., Material description, description, Complete clamp, Ansi type reel insulation, machine, machine, Preformed shot, Complete: includes only end bolts for the material required in the anchor to see the respective standard., Double cross-over, structure:, quantity, Round, plant, frontal, Stirrup for reel, Metal post, Metal post, Metal post, Metal foot post, Dimensions in meters, Simple secondary anchor, Dimensions in meters, Pushed secondary cut, Dimensions in meters, Double cross-over, Secondary backtack, Led lamp installation, Isometric

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Plan
Category
Additional Screenshots
File Type dwg
Materials Concrete, Steel, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

CAD Drawings

Leave a Reply