Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Lightened DWG Block for AutoCAD

Design lightened plant 40 m2

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

distribution, esc, lightened first level, esc., lightened level, esc., staircase box, Main beam:, esc, secondary beam:, esc, beam edge, section, section, not splicing more than the total area, for iron of cm. for iron, the splicing length being equal, inside will be spliced ​​on the supports, the length of splicing, in case of not splicing in the zones, for lightened beams steel, in consultation with the designer., in the same section, indicated with the percentages, interior reinforcement, anyone, detail for cutting rods in compression traction, r. n. c. rules, f’c shoes, secondary beams f’c, structural columns f’c, pg., p.m., clay king clay brick unit, carrying capacity, steel, rules, ground, of overloads, coatings, confinement column f’c, beams, cm., confinement columns, iron joints, steel grade fy, the central third, cm., levels, prof. of foundation m., mortar, joint cm., structural columns, shoes, cm., factor of, compression masonry f’m, clay brick kk clay, weight specific masonry, masonry, of materials, foundations f’c, simple concrete, reinforced concrete, false floor f’c, overcrowding f’c, soles f’c, main beams f’c, Technical specifications, rooftop, stairs, the quality of the reinforcing steel shall not exceed that specified for steel grade arn, the wide bead ratio of the beams shall not be less than, in a plane perpendicular to the axis of the three-quarters of cant of the, the width of the beams shall not be less than or greater than the width of the column, the effective cant be less than a quarter of the free light., splices should be made only as required by the drawings of the, confined by closed stirrups spaced no more than, the overlapping splices of the reinforcement in investment zones must be, welded overlaps should not be made in the reinforcement within an area, the axial load must not exceed f’c ag. in case the element, by, mpa, beam each side., by welding., technical specifications as authorized by the inspector., by mechanical joints., the applications may be of different types:, should be treated as an element in flexocompression., lengths not exceeding cm., located on the face of the knot., the specified strength of the concrete shall not be less than, beams that must withstand earthquake forces must comply with the provisions of this, center of the height of the element with a length greater than fy db no, the longitudinal column bars will preferably be spliced ​​within the, the reinforcements should preferably be spliced ​​in areas of low stress., overlapped corrugated bars, cm. for f’c smaller than the length of splicing will be increased by one third., Compression indicated must also be greater equal f and db not smaller, the minimum length of a splicing overlapping in compression will be the longi

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel
Measurement Units
Footprint Area
Building Features
Tags , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT