Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Metal Roofing Of Curve DWG Block for AutoCAD

FREE ROOF OF LIGHT 35X64 MTS. IN MODULES A 8 MTS. IDEAL FOR SEMI OLIMPIC POOLS OR MULTISPORTS COURTS

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

npt, npt, goes up, ptr c., ptr c., ang., your B. c., your B. ced., your B. c., your B. ced., your B. c., your B. ced., tube c., your B. c., n.t.n., architectural plant., scale, cut, welding, structural steel notes:, the first stirrup will be placed cms. of the plane of the, joints should be avoided, thickness specified in the structural concepts, all welds must be made according to the types, flambeos of material, the filling will be of good quality bench material, supports, oriented., the materials workforce of the structures of, steel should be free of scabs, holes., strange to steel., burst any other particle, the surfaces of parts united with screws of high resistance, that are in contact with the screw head with the, they will not have a greater inclination of, plane normal to the axis of the screw., the use of a guide punch in the screw holes, during assembly should not distort the metal to enlarge the, holes whose diameters need to be increased in order to, place the screws should be enlarged by means of a drill bit, the use of a torch is not permitted., be connected together as indicated by the corresponding connection detail., all structural elements formed by plates shall be, indicate the basic geometry., transport of the elements is necessary., must be in accordance with the specifications, all materials used in the fabrication of structures, sufficient proportion of each component part of the, Structural drawings are not considered as a workshop because only, all members of structural steel specified in, The project plans should be fabricated in a workshop for, which manufacturing plans should include the information, as well as the position of ties that due to, indicated the type of connection any modifications, which must be previously approved by the structurist., the contractor is responsible for verticality, safety of all elements of the structures during the, must place all temporary supports, the connections the manufacturing tolerances assembly, the columns will be placed on concrete data, the elevation determined in the planes, keep them in position until they have been done, the manufacturer of the steel structure shall comply with sections, t.m.a. mm., partially drowned in concrete., should not be allowed to bend straightening rods, the cuts of the rods should end in points, reds separated a min. of cms., level section., should not overlap more than steel in one, air grade corrugated steel, soil., a concrete template between the piece, minimum coating of cms. of cms. if it is placed, its reinforcing steel should have a, every element cast in contact with the ground, painting steel structure, the minimum acceptable thickness for the paint is of microns, with a wire brush for the removal of, earth oxide

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Steel, Other
Measurement Units
Footprint Area
Building Features A/C, Pool
Tags , , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT