Plan Details Of Control Equipment Canalization DWG Plan for AutoCAD
Details – Specifications – sizing -constructive cuts.
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
S.a. Of c.v., Engineering associates, Electric substation room., Property of cfe., Comes from the street, Property of cfe., Private transformer, do not. Meter, sub. Elec. particular, Hm rate, Kva, Radial operation, Project kva pedestal, Connection:, Radial operation, Brand tegesa, series, rule, Is far total, Proy. Cabl. Xlp alum., Metal ring, Neutral cu desn., parking lot, Detail of canalization m.t s.e. Kva, Floor plan, Plant cover, cut, Registration without background for, Low water level, On bench type, Low voltage log, rule, Of concretions in concrete reinforcement electrowelded mesh kpa corrugated lime. Cm coating. Apparent appearance inside the exterior thickness of the walls of cm. Finished cement polished steel frame cm. By concrete cover with welded mesh steel frame cm. Per aggregate cm. In case of being completely sealed, a piece of mm will be installed in the bottom wall to introduce the ground wire. The ground electrodes outside the register. The records must be identified with the name of the month the first three serial number of the marks must be highlighted on any of the inner faces of the register without interfering that of the pipelines of the rush with letters of cm. If the quality of the materials is checked by an authorized armed laboratory, it will be verified on site. In case the records are must be inspected the lapem during your must have your corresponding notice. Concrete cap covers detail will apply the type of install. For land with high level land with saline the concrete use contain sulfate resistant compounds. The number of holes for the arrival of the pipelines in the project., Applications apply to all types of floors except. Very soft soils qa kpa expansive soils. Submerged soils. Note: in these cases it is recommended to determine the soil characteristics to make the corresponding structural revision, Cm. Per cm. Long soldiers frame on each to the center side., Cm. diameter., Cm. Of diameter in the wall, floor, Cap detail: cut, Cm., Of faith. Cm. diameter., Outside floor, Screw details, Angle steel cm., Cap detail: cut, Cm. Of diameter in the wall, Reinforcement e.m on stool f’y kpa, Round iron cm. galvanized, Mesh, Use: housing cables low voltage connections in underground distribution networks up to monopolar cables for connection., Isometric, Outside floor, Angle steel cm., Cm., Round iron cm. galvanized, Hydrant, do not., Street, bomb of, Water., Water., bomb of, Electric rack, Electric rack, Electric rack, Cto. From trios, reactor, Water tank, access, lift truck, natural terrain, trench, elevator, trench, trench, preparation, Of solutions, Valv. he., Valv. he., return, Operator’s stand, Gas, Electric rack, Nitrogene, dilution, channel, Sardine, trench, Electric rack, Hydrant, Exist., Suction duct, flow, of air, departure, entry, trench, recovered, area of, natural terrain, of control, dryer, Electric rack, Vcm, Vcm, Electric rack, Railroad track, Rail stop, Rainwater channel, Access area, Compressors, area of, Compressors, Drying area, refrigerant, compressor, Vcm, Alpha laval, area of, Compressors, Column of, washed, Column of, washed, system of, Against fire, registry, Existing rack, Bomb nash, Bomb nash, trench, Caustic scrubber, Caustic cooler, Caustic scrubber, Caustic cooler, Street, Electric rack, Elec., C.i., Of access, Elec., Reg., system of, aspersion, Hydrant, display, Column of, washed, Bomb nash, compressor, natural terrain, Shed, production, registry, New rack, compressor, unity, unity, compressor, Cooling units, Relocated, Cylinder storage, Batter, Compressors, trench, parking lot, Batter, Electric rack, Batter, column, column, peroxide, tank of, Bulk drum, or. refrigeration, New project street, Railways project, Future available area, Rail freight silos, Scale area, Road lighting, do not., detail, do not., Detail no., Arrival of tray cable conduit generator, do not., Duplex contact extra-terrestrial service, With gray plate cover, Copper-free aluminum rectangular series type registration box, do not., Aluminum type copper condulet with aluminum lid packing, Angle of carbon steel thickness mm, Galvanized steel type clamp with two hex nuts, High density polyduct of diameter, do not., Angle of carbon steel thickness mm, Detail no., Cant, unity, Cant, unity, Cant, unity, Cant, unity, Cant, unity, P., P., Pza, P., P., Tmo., P., P., P., Tmo., P., Tmo., Male straight connector for pvc tube, Condulet mmd type of aluminum diameter l
Raw text data extracted from CAD file:
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
S.a. Of c.v., Engineering associates, Electric substation room., Property of cfe., Comes from the street, Property of cfe., Private transformer, do not. Meter, sub. Elec. particular, Hm rate, Kva, Radial operation, Project kva pedestal, Connection:, Radial operation, Tegesa brand, series, rule, Is far total, Proy. Cabl. Xlp alum., Metal ring, Neutral cu desn., parking lot, Detail of canalization m.t s.e. Kva, Floor plan, Plant cover, cut, Registration without background for, Low water level, On bench type, Low voltage log, rule, Of concretions in concrete reinforcement electrowelded mesh kpa corrugated lime. Cm coating. Apparent appearance inside the exterior thickness of the walls of cm. Finished polished steel frame framing cm. By concrete cover with welded mesh steel frame cm. Per aggregate cm. In case of being completely sealed, a piece of mm will be installed in the bottom wall to introduce the ground wire. The ground electrodes outside the register. The records must be identified with the name of the month the first three serial number of the marks must be highlighted on any of the interior sides of the register without interfering with the ridge ducts with letters of cm. If the quality of the materials is checked by authorized armed laboratory will be verified on site. In case the records are must be inspected the lapem during your must have your notice of correspondent. Concrete cap covers detail will apply the type of install. For high-level soils with saline concrete use contain sulfate resistant compounds. The number of holes for the arrival of the pipelines in the project., Applications apply to all types of floors except. Very soft soils qa kpa expansive soils. Submerged soils. Note: in these cases it is recommended to determine the soil characteristics to make the corresponding structural revision, Cm. Per cm. Long soldiers frame on each to the center side., Cm. diameter., Cm. Of diameter on the wall, floor, Cap detail: cut, Cm., Of faith. Cm. diameter., Outside floor, Screw details, Of angle steel cm., Cap detail: cut, Cm. Of diameter on the wall, Reinforcement e.m on stool f’y kpa, Round iron cm. galvanized, Mesh, Use: housing cables low voltage connections in underground distribution networks up to single-wire cables for connection., Isometric, Outside floor, Of angle steel cm., Cm., Round iron cm. galvanized, Hydrant, do not., Street, bomb of, Water., Water., bomb of, Electric rack, Electric rack, Electric rack, Cto. Of trios, reactor, Water tank, access, lift truck, natural terrain, trench, elevator, trench, trench, preparation, Of solutions, Valv. he., Valv. he., return, Operator’s stand, Gas, Electric rack, Nitrogene, dilution, channel, Sardine, trench, Electric rack, Hydrant, Exist., Suction duct, flow, of air, departure, entry, trench, recovered, area of, natural terrain, of control, dryer, Electric rack, Vcm, Vcm, Electric rack, Railroad track, Rail stop, Rain channel, Access area, Compressors, area of, Compressors, Drying area, refrigerant, compressor, Vcm, Alpha laval, area of, Compressors, Column of, washed, Column of, washed, system of, Against fire, registry, Existing rack, Bomb nash, Bomb nash, trench, Caustic scrubber, Caustic cooler, Caustic scrubber, Caustic cooler, Street, Electric rack, Elec., C.i., Of access, Elec., Reg., system of, aspersion, Hydrant, display, Column of, washed, Bomb nash, compressor, natural terrain, Shed, production, registry, New rack, compressor, unity, unity, compressor, Cooling units, Relocated, Cylinder storage, Batter, Compressors, trench, parking lot, Batter, Electric rack, Batter, column, column, peroxide, tank of, Bulk drum, or. refrigeration, New project street, Railroad project, Future available area, Rail freight silos, Scale area, Road lighting, do not., detail, do not., Detail no., Arrival of tray cable conduit generator, do not., Duplex contact extra-terrestrial service, With gray plate cover, Copper-type rectangular aluminum-type rectangular register box, do not., Aluminum type copper condulet with aluminum lid packing, Angle of carbon steel thickness mm, Clamp type galvanized steel with two hex nuts, High density polyamide of diameter, do not., Angle of carbon steel thickness mm, Detail no., Cant, unity, Cant, unity, Cant, unity, Cant, unity, Cant, unity, P., P., Pza, P., P., Tmo., P., P., P., Tmo., P., Tmo., Male straight connector for pvc tube, Condulet mmd type of aluminum diameter l
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Plan |
Category | Water Sewage & Electricity Infrastructure |
Additional Screenshots | |
File Type | dwg |
Materials | Aluminum, Concrete, Steel, Other |
Measurement Units | |
Footprint Area | |
Building Features | Elevator, Car Parking Lot, Garden / Park |
Tags | alta tensão, autocad, beleuchtung, constructive, control, cuts, details, détails électriques, detalhes elétrica, DWG, electrical details, elektrische details, equipment, haute tension, high tension, hochspannung, iluminação, kläranlage, l'éclairage, la tour, lighting, monitoring, plan, sizing, specifications, torre, tower, treatment plant, turm |