ADVERTISEMENT

ADVERTISEMENT

Triplex DWG Section for AutoCAD

House – Plants – Sections – Elevations –

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

patio serv., shop, garden, living room, hall, kitchen, bedroom, s.h., corridor, cement floor, water meter, cold water pipe, hot water pipe, tub crossing. no connection, cross pipe, tee, tee with rise, tee with slope, universal union, gate valve, globe valve, check valve, float valve, irrigation key, drain pipe, vent pipe, cross, tee straight, sanitary tee, double sanitary tee, and simple sanitary, and double sanitary, reduction, trap p, vent terminal. on roof, vent terminal wall, register box, bronze threaded register, drain, legend, and drain according to the specifications indicated in the cnc, to the central drains., technical specifications, construction detail, wall, column steel, see table of columns, striped joint in, the floor beam or collar, or in the sobrecimiento., sufficient roughness and, in addition they must be, clean of particles, stirrups colunmas, additional stirrups, concrete in columns, the concrete of colunmas, must reach until the foundation, morteo :, maximum, ceramic floor, living room, star – tv, ceramic finished floor, roof, npt, living, main elevation, patio, ss.hh, patio garden, scy, scj, scz, scx, a electrocentro network, r _, earth well – compute, c-ix, reserve, sub feeder, ci, secondary network, feeder, distribution board, with automatic switch – thermo magnetic, electric stove, electric heater, tea, ti , exit for outside telephone,, sali equipment bell, pushbutton, general distribution board, energy meter, well grounded, pt, kw-h, exit for indoor telephone, embedded pipe in the ceiling or wall – energy, embedded pipe in floor – energy, the number of stripes indicates the number of cables, connection to grounding network, outlet for grounding outlet, height above the npt, exit boxes, symbol, lighting center, junction box, interior telephone passage box, simple switch , double, and three way, description, square step box, the arrow number indicates the number of circuits, spot light, mg sulfate, sifted earth, earth well, connector, roof electrical installations, rooftop sanitary facilities, va to collecting network, comes cold water of silk-huanuco, boot, ladder, shoe detail, own material, stuffed with, detail, column table, type, stirrups, before starting the second, clean and moisten, mortar, for a better ad inheritance, for the second day, for solid units., note, c.- for lightened and flat beams, steel, specified, increase the length of junction, indicated or with the percentages, b.- in case of not joining in the zones, in the same section, interior is joined on the supports, f’c, upper, lower, bar, length of development, lower bar, without scale, upper bar, beam, corrugated bars to traction, development lengths for, bars upper, values, inner reinforcement, h any, length, of the hook, length of development in cm., lower bars, technical specifications, beams, footings, wall – column, bracing detail, special care should be presented to the correct placement inside , of the formwork of all the indicated irons., and other elements that should be embedded in the concrete., These elements should be well insured and avoid that, move during the process or of placing the concrete., the formwork should be sufficiently impermeable as, to prevent loss of grout and mortar, the inside face of the formwork should be clean and free of particles, various., the minimum time of removal of the formwork and elements of, sustain, will be governed by the following times:, – beam and column sides:, characteristics of the formwork, removal of the formwork, confinement columns, foundations, flooring for footings, concrete footings, concrete columns, overlays, false floor, concrete beams, masonry mortar, corrugated steel, standards, coatings, formwork and stripping, before emptying, concrete clean well, teeth avoiding the formation of burrs, and crabs., In turn use an appropriate technique of vibration or of chuteo, avoiding as much as possible the breakage of the teeth., typical detail of lightened, ø according to plant and type of lightened, detail of anchor of steel, of slab in Beam, note: avoid overlapping in areas of minimum diameter of bending in longitudinal bar, nominal size of the aggregate in columns, plates, beams, slab, ladder and shoe, flooring, minimum diameter of bending in stirrups, slab coating and staircase, beams and columns covering, shoe covering, masonry mortar, masonry compression resistance, masonry unit compression strength,

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Section
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel, Other
Measurement Units Imperial
Footprint Area
Building Features Garden / Park, Deck / Patio
Tags , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT