ADVERTISEMENT

ADVERTISEMENT

House Lolo DWG Full Project for AutoCAD

Project room full house, floor plans, sections, facades, structural and plant facilities isometric.

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

ran, ban, red, miriam, murete, thickness of the shoe, living room, bedroom, laundry room, patio, garage, architectural floor, low, high, main facade, kitchen, dining room, up, low, low architectural plant, plant high architectural, bap, roof plant, comes from network, general, bathroom, bathroom c, bathroom d, bathroom b, bap, cistern, baf, hydraulic installation, sac, bac, cespol, basin, shower cespol, laundry, tarja , washing machine, isometric, specifications:, sanitary installation, shower, saf, pump, pvc pipe, bearing surface, household outlet type, note:, pump size, in no way reduce, the suction pipe must be exactly , pichancha, absorption pipe, electrical connection, lighting output, flying buttress, simple polarized single-phase contact, single damper, ladder damper, bell, register box, distribution board, light and power company meter, slab pipe or mur or, pipe per floor, copperweld rod for connection to ground, installation of gas, b.i.g., s.l.g., s.i.g., room tv, main, rec. main, plastic tank, heater, gate valve, float valve, or hot water, low column of cold water, tee, indicated, hot water line, cold water line, cold water column rises, for each of the outputs, symbology, vent, reventon to give slope, bed of gravel and sand, mixture, template slope, iron strainer, flattened polished, channel or half pipe, cross section of a record, with strainer of a rainwater descent, wall of, partition, template, concrete, poor, concrete or mosaic cover, tributary, longitudinal section of a register, flow, specification notes, the albanals that dislodge the wastewater, the albanals will be constructed of concrete or other materials that the project specifies., the pipes that form the albanal will be installed, center between boxes of record., prior to the installation of the pipes, a gravel and sand bed will be placed, tepetate, etc. duly compacted, the pipe will be placed with the bell upstream and its placement will begin, upstream downstream following the slope specified in the project. The pipes should form a continuous conduit, correctly aligned. the pipe saturating the interior part of the hood and the exterior part of the mouth, without the pipe bell to be assembled. the lower quadrant of the bell will be filled with, placing on it the bell-free part of the pipe to join the following section., registers for albanal, albanal, registry detail, mixing key, coflex tube, valve, connector cu, firm, or slab, floor level, finished, tank toilet, key, slab, angle valve, cap plug, coflex, plant, cut, side, plant, dryer detail, no scale, detail of toilet, detail sink, detail of shower, detail of tarja, all connections should be made to the registries or other connections, except rainwater., grid, pluvial installation, concrete chain, armed, firm concrete, block wall, cement or, fine polishing, half-round, compacted tepetate, natural ground, minimum, tube, pend., concrete cover, cement mortar, finished floor, cement mortar, finished sand, flattened, register for albanal., minimum dimensions for albanal records, the lid, can be blind, with frame and contramar-, co of iron or structural steel., the interior finish of the walls, should present a smooth and resistant surface, in case of, being partition or annealed mud, it will be covered with a, flattened cement-sand mortar in proportion, fine cement, polished with a metal trowel., on the bottom of the registry floor, the walls of annealed red partition are demolished, remaking the upper part of the walls with a perimeter fence of reinforced concrete, as indicated, the project. In the case of registers for albanal, the foundation will carry a half-pipe of the same drainage pipe or in the casting process. firm, they will build the gray stockings, projection hoop, metal, due to the greater resistance to degradation, cases where the terrain is wet or salty, of common red partition, especially in those, it is recommended to use cement block , instead, cement block., register for albanal, filter, button auction, low pressure regulator, regulator input, stove connection detail, filling line, service line, b.p. regulator, vent, curl. cu flx., filling valve, heater detail, stove detail, stationary tank detail, material list, l.ll., slll., up filling line, blll., low filling line, crk, rigid copper type k , crl, rigid copper type l, meter, technical specifications, well to earth, and compacted, sifted earth, conductor, the

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Full Project
Category
Additional Screenshots
File Type dwg
Materials Concrete, Plastic, Steel, Other
Measurement Units Metric
Footprint Area
Building Features Deck / Patio, Garage
Tags , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT