ADVERTISEMENT

ADVERTISEMENT

Residencial Building 4 Levels DWG Full Project for AutoCAD

Appartnents 3 bedrooms – In lower plant appart. 2 bedrooms with studio – Type plant 3 bedrooms – Complete project – Plant – Installations – Structures – Constructive details

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

jaedin, empty, planter, architecture fourth floor – floor, architecture third floor – floor, architecture second floor – floor, dining room, floor loceta, kitchen, ceramic floor spanish, room, ss.hh., cl., floor parket, hall, balcony, roof fence projection, lift, door projection, span key, high width, alfeizer, type, architecture first floor – floor, room, floor polished cement, service, bbq, grass, garden, floor gress ceramic, terrace, floor, polished cemeno floor, car-port, study, Andean tile roof, vacuum duct, ventilation, projection. beam, projecting of light slab, ridge shaft, h ”, stair case, projection. of summit, v-ch, proyecc. roof, joists, typical detail of lightened, ø according to type of lightened, ø according to plant and type of lightened, h anyone, b.- in case of not joining in the zones, indicated or with the percentages, specified, increase the length of splicing, interior splices on the supports, c.- for lightened and flat beams, steel, in the same section, note, interior reinforcement, values, detail for cutting of rods in traction and compression, columns, beams, coatings, foundations, slabs, walls, length of development, without scale, beam, upper bar, lower bar, bar, upper, lower, development lengths, for corrugated bars at traction, length, hook, del, technical specifications, light concrete, screed for footings, overburden, steel, bearing capacity, concrete beams, concrete columns, concrete footings, edge beam detail, reinforcement in lightened plant, see distribution of, cuts bb and cc, height variable, detail staircase first floor, long. desar in cm., stair detail, typical third and fifth sections, typical fourth and sixth sections, var., column detail, typical of confinement, additional, minimum disposition of stirrups, in meetings, connection to walls, confined, see table , f’c, lower bars, upper bars, column table, detail of footings, see distribution of stirrups table of columns, detail, details of foundation, vertical reinforcement, see table of columns, stirrups, masonry compression, specific masonry weight, thickness of lightened, overload, finishes, solid brick kk clay, concrete, technical specifications, bbq, sshh, patio, carport, access, staircase start, foundation plant, the structural system raised is of the type contributed, in this sense the columns and beams, in both directions must be independent, ie avoid confinement with walls, shoe section, shoe box, note: column, boot distribution, reinforcement, cant, insulated shoe a, observations, table of confinement columns, see detail of the portico reinforcement bb, note: the distribution of the reinforcement is idem to the second typical section-fourth and sixth., portico bb, detail of beams, portico cd, portico ef, portico gg , concrete walls, diam. min.doblado abutments, size max. aggregates, masonry mortar, resist. comp. masonry, overlapping splices, subject to tension, subject to compression, splices in the reinforcement, section for the design of the longitudinal steel., – the overlaps of bars forming bundles shall be based on the required overlap length, – the bars spliced ​​by means of overlaps are contact in elements subject to bending, no, package shall not coincide within the same length of overlap, overlapping splices of corrugated bars, – the minimum length of overlap in splices overlapping in tension shall be in accordance with the re, where is the length of the joint, and ld is the length of development in traction., – the joints in areas of high stress should preferably be avoided, however, if they were, strictly necessary and if less than half is spliced of the bars within a length, required to overlap type b splices should be used. if more than half of the tabs are spliced ​​within a required length of overlap, splice type c shall be used, – the minimum length of an overlap splice in compression shall be the length of development in, – the beams that must resist earthquake forces must comply with what is indicated in this, must be treated as an element in flexocompresión., – the sites may be of different types: technical specifications or as authorized by the inspector., beam on each side., – should not be overlapping or welded joints in the reinforcement within an area, – the overlapping splices of the reinforcement in areas of stress inversion, should remain, – the splices should be made only as required or allow the design plans, the – the quality of the reinforcing steel shall not exceed what is specified for arn grade steel, details, bb portico, beam sections, cd portico, portico ef, portico gg

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Full Project
Category
Additional Screenshots

File Type dwg
Materials Concrete, Masonry, Steel, Other
Measurement Units Metric
Footprint Area
Building Features Garden / Park, Deck / Patio
Tags , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Startland Construction

Leave a Reply

ADVERTISEMENT