ADVERTISEMENT

ADVERTISEMENT

Set Of Electric Planes Of Family House DWG Detail for AutoCAD

SET ELECTRIC PLANES UNIFAMILY HOUSING SEPARATE FOR 4 CIRCUITS,UNIFILAR DIAGRAME AND TABLE OF CHARGES OF EACH CIRCUIT ;ISOMETRIC DETAIL OF UNDERGROUND CONNECTION, AND UNION BRIDGE CONNECTION OF THE SWITCH IN THE HOUSE AS PHYSICAL EARTH EACH CIRCUIT

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Tel, TV., N.p.t., Galvanized metal, Three-way, Of load, Thermomagnetic, Buttress, draft, San david house, Symbology, address:, owner:, House room, turn:, February of, date:, location:, electrical installation, electrical installation, Of weather, Wiring diagrams, Number of threads, caliber, color, key, use, Awg, black, phase, Awg, White, neutral, Awg, naked, Grounding, Ceiling, Recessed spot type, Three-way, Of load, Thermomagnetic, draft, San david house, Symbology, address:, owner:, House room, turn:, February of, date:, location:, electrical installation, electrical installation, Of weather, Number of threads, caliber, color, key, use, Awg, black, phase, Awg, White, neutral, Number of threads, caliber, color, key, use, Awg, White, neutral, Awg, Red, he came back, Number of threads, caliber, color, key, use, Awg, black, phase, Awg, Red, Stairway connection, Number of threads, caliber, color, key, use, Awg, black, phase, Awg, Red, he came back, Lighting cabling, Number of threads, caliber, color, key, use, Awg, black, phase, Awg, White, neutral, Awg, Red, he came back, Number of threads, caliber, color, key, use, Awg, black, phase, Awg, Red, he came back, Number of threads, caliber, color, key, use, Number of threads, caliber, color, key, use, Awg, White, neutral, Awg, Red, Star connection, Center, of lighting, Three-way, Of load, Thermomagnetic, draft, San david house, Symbology, address:, owner:, House room, turn:, February of, date:, location:, electrical installation, electrical installation, Of t.v., For phone, Of weather, Copperweld, With earth fault protection type gfci, Load center circuits recessed, Main cabinet switch, Pump plant contacts, High floor contacts, Lighting plants high low, Black phase neutral white n. T.f. Orange polyduct, Black phase white neutral red return poliduct orange, microwave, Cfe, Black phase neutral white n. T.f., Cont. Duplex cont. Duplex type outdoor lighting fixtures, Load board, Project: san david house, Identification: load center circuits, Degree of protection:, Type of attachment: main shoes, Phases:, Volts:, Amps:, general specifications, You must respect the color code: phases: any color minus green white. Neutral: gray white. Earth: bare green. The grounding of the cabinets must be done with mechanical shoe type punchable eye. The cable used inside the pipes must be of a single piece of joints which must be adequately insulated by replacing the insulation that has been removed. All the cable must be of copper with insulation of the emission type of fumes with a temperature of the insulation of the paths of the canalizations are necessary if they will be adjusted in field registering in the logbook. Will be used as an integral type galvanized square metal box according to the diameter of the pipe. The pipes by wall ceiling will be orange pipeline. The canalization per floor will be with orange poliduct. The hidden contacts switches will be placed in boxes galvanized chalupas embedded in walls., Type of installation: recessed, Service: normal, Dimensions mm, Date: December of, circuit, Poles, description, Volts, Amps, F.p., Drivers, protection, canalization, Pump plant contacts, High floor contacts, Ground floor lighting, microwave, Awg, Awg, Awg, Orange polyduct, Phases, total, Demand factor, Load goes, current, Copperweld copper ground rod, Socket connection, Junction jumper connection on load center main switch, Neutral bar, Physical ground shoe, Connecting bridge lime. Awg, T.f., Come from cfe meter, Here must be the union bridge, Ceiling, Buttress, Center, of lighting, Three-way, Of load, Thermomagnetic, draft, San david house, Symbology, address:, Group builders s.a. Of c.v., owner:, House room, turn:, February of, date:, location:, electrical installation, electrical installation, Of t.v., For phone, Underground, Of weather, Copperweld, With earth fault protection type gfci, general specifications, You must respect the color code: phases: any color minus green white. Neutral: gray white. Earth: bare green. The grounding of the cabinets must be done with mechanical shoe type punchable eye. The cable used inside the pipes must be of a single piece of joints which must be adequately insulated by replacing the insulation that has been removed. All the cable must be of copper with insulation of the type emission of smoke with a temperat

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Plastic
Measurement Units
Footprint Area
Building Features Deck / Patio, Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , , , ,