One Family Housing– Two Levels DWG Plan for AutoCAD
ONE FAMILY HOME– TWO FLOORS COMPLETE: ARCHITECTURAL PLANS ;SECTIONS AND ELEVATIONS ; PLUMBING, ELECTRICAL, LIGHTING AND FOUNDATIONS.
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
garden, patio, npt, supporting wall, partition wall, natural terrain, overhang, foundation, mesh, ladder, overloads, roof, rooms, stairs, concrete:, coverings, flat beams, slabs, corrugated iron, columns bracing, concrete cyclopean, concrete overburden, bearing walls, soil factor, masonry: structural configuration, bearing capacity, depth of soil, soil period, r. perpendicular to the facade, r. parallel to the façade, maximum displacement, maximum relative displacement, coefficient of acceleration, technical specifications, beams, smooth iron, columns, columns, partitions, terrain :, structure, zone factor, use factor, steel :, plates, beams and slabs, false floor, flooring, brick tambourine, regular rectangular, expansion board, level, bxt, column table, section, nnt, beam sobrecimiento, detail, detail of foundations, detail of plates, foundation of stairs, type, spacing, abibos in columns, plane nº :, plane :, property :, project :, engineer :, multifamily housing, foundations and details, nº cip:, prov. and region: arequipa, district: miraflores, department: arequipa, location :, iden, cristian vizcarra adriano, see floor, view datalle, projection, empty well, roof, occupied area:, free area:, roofed area :, kitchen, cut a – a, hot water outlet, cold water outlet, drain outlet, floor outlet, alternative, wall outlet, drain outlet, wall, false floor level, typical shoe, quality and quantity to ensure waterproofing, they will be made of bronze and installed at the finished floor level, corresponding water seal., never inside the columns, technical specifications – drainage, atmospheric in each sanitary appliance and protect the base, can be masonry or concrete , heavy type for drain of bell spike, will be to the side of the structural columns, prefabricated, in both cases with tarrajeo polished, the drain pipes will be filled with water, after, they reach the roof, they should be prolonged by ma, sealed with special glue., without allowing leaks., be an accessible roof., hydraulic test, exposed, could be installed with a universal union., the accessories of sanitary devices should be of, technical specifications-water, quality such, that guarantee a perfect operation, the help of a hand pump, until reaching a pressure of, the cold and hot water pipes, will be filled with water with, to the diameter of the pipe that is being worked., detail of installation of heater electric, gate valve, simple union, safety valve, exit ac, universal union, check valve, enter cold water, to the drain network, resistance, thermostat, roof slab, angular frame, sink, vertical cut , finish, floor, floor, removable grid, sanitary facilities, wall, additional, place rolled, sewer, column widening, see table of columns, reinforcement for descent, ducts, link equipment ncial, white, red, green, tw wired, neutral phase, distribution board, the bars will be electrolytic copper of the following, – bars and accessories. must be isolated from the whole gavinete, – wall-mounted box, metal type, – door and sheet, finished with epoxy paint, general switch bars, capacities:, concrete box, earth well, concrete cover , to lower resistance, add chemical additive dose, connector, bronze connector, anderson ab, description, color code, color, phase, neutral, earth, red, blue, black, white, yellow, yellow – green, dako, see column table, distribution of abutments, typical detail, columns, subcimiento, sobrecimiento, foundation, goes, box of beams, vs, compacted terrain, brick wall kk solid, compacted terrain, filling, garage, closet, ceiling projection, dining room, room, store, ss.hh., bedroom, living room, hall, first level, second level, none, bronze, legend, water meter, general key, local key, irrigation tap, tee for water, cold water network, hot water network, water outlet, pvc pipe, see plan, pvc sap, register box, threaded register, sump, tee, yee, arrival rainwater, drain, outlet, cold water, drain outlet, cold water outlet, hot water outlet, det. water outlet and drain in toilets, copper net naked well to earth, thermo-magnetic automatic switch, connection, energy meter, distribution board, special, ceiling, recessed, box type, description, legend, light center, symbol, pass box, tv – cable, bracket, spotlihg, intercom, telephone, high power outlet, npt part inf., height, well grounded, floor, s, sc, number of drivers, t.v. telephone, outlet, n.p.t., switch, outlet
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Plan |
Category | House |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Masonry, Steel, Other |
Measurement Units | Metric |
Footprint Area | |
Building Features | Garden / Park, Deck / Patio, Garage |
Tags | apartamento, apartment, appartement, architectural, aufenthalt, autocad, casa, chalet, complete, dwelling unit, DWG, elevations, Family, floors, haus, home, house, Housing, levels, logement, maison, plan, plans, plumbing, residên, residence, sections, single family residence, unidade de moradia, villa, wohnung, wohnung einheit |