Control Room Circuit Schematic, Hydro-Electrica Turbine Generator DWG Model for AutoCAD

This single line model is the electrical system for protection, control and measurement of a hydroelectric francis.turbine

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

measurer, Multifunction, Shark, Hey, Power outlets, illumination, force, work:, owner:, Plan name:, date:, scale:, Rev .:, Format:, Unilateral diagram system protections control, reservation, source, Of batteries, charger, card, valve, proportional, Controller, speed regulator, tickets, Rtd, alternator, Servomotor of guidelines, Rtd, Open valve, Position feedback, Of camera, level, Sensor, Closed valve, Turbine francis, Kato, countryside, Icc, Ah, Vcc, Avr, Icc, Control panel synchronization transformers measurement generator, Control panel generator control, switch, fuse, Disconnector, Protective relay, Generation output board, Auxiliary services board, Overvoltage protection, Overvoltage ground fault protection in neutral, Coupling capacitor, lighting rod, Power voltage transformer, Synchronoscope, Removable switch with trip coil, Double frequency, Electric motor of alternating current, Double voltmeter, Current transformer, Minimum voltage protection, Sync check, Active power investment protection, Negative sequence current protection, Loss of excitation protection, Over temperature protection, Timed overcurrent protection, Overexcitation protection, Negative sequence overvoltage, Mikro, controller, measurer, Multifunction, Satec, Load-sharing control, Temperature monitor, Multifunction relay, protection, load, hydraulics, Of the generator, Alarm panel, G.e., hydraulics, Directional overcurrent protection, Switch reclosure, Overfrequency protection, Power swing lock, Directional homopolar overcurrent protection, Low frequency protection, Differential transmission line protection, Transformer differential protection, Homopolar overcurrent protection, Distance protection between ground phase, Distance protection between phases, governor, Woodward, R.p.m., Display, Retyg, Woodward, Mpu, Retyg, source, Of batteries, charger, card, valve, proportional, Controller, speed regulator, tickets, Rtd, alternator, Servomotor of guidelines, Rtd, Open valve, Position feedback, Of camera, level, Sensor, Closed valve, Turbine francis, Kato, countryside, Icc, Ah, Vcc, Avr, Control panel synchronization transformers measurement generator, Control panel generator control, Mikro, controller, measurer, Multifunction, Satec, Load-sharing control, Temperature monitor, Multifunction relay, protection, load, hydraulics, Of the generator, Alarm panel, governor, Woodward, R.p.m., Display, Retyg, Woodward, Mpu, Retyg, source, Of batteries, charger, card, valve, proportional, Controller, speed regulator, tickets, Rtd, alternator, Servomotor of guidelines, Rtd, Open valve, Position feedback, Of camera, level, Sensor, Closed valve, Turbine francis, Kato, countryside, Icc, Ah, Vcc, Avr, Control panel synchronization transformers measurement generator, Control panel generator control, Mikro, controller, measurer, Multifunction, Satec, Load-sharing control, Temperature monitor, Multifunction relay, protection, load, hydraulics, Of the generator, Alarm panel, governor, Woodward, R.p.m., Display, Retyg, Woodward, Mpu, Retyg, Substation

Raw text data extracted from CAD file:

PREMIUM

File Details

File Type
DWG
Type
Model
Language
Spanish
Materials
Wood
Features
Car Parking Lot
Uploaded by
CAD Drawings
Downloads
1 downloads
Category
Water Sewage & Electricity Infrastructure
Published
Aug 2, 2017
Price $3.87
or

or get unlimited access from $7/mo

Browse All Downloads