Designs CAD
Fire protection detail
Translating…
– – SCALE 1:100 MTS BY PLOTTED PLOT PLOT FILE SCALE NUMBER DATE REVISED DWG. REV. BY REV. DATE \A1;750 (CLEAR WIDTH) \A1;100 \A1;200 \A1;(CLEAR DEPTH) \A1;750 (CLEAR WIDTH) \A1;100 \A1;800 (CLEAR HEIGHT) \A1;900 \A1;(ABOVE FLR.LEVEL) \A1;75 \A1;VARIABLE \A1;75 \A1;75 \A1;75 \A1;50 \A1;50 \A1;50 \A1;50 \A1;50 \A1;30° \A1;45° \A1;102mm(MIN.) \A1;152mm(MAX.) \A1;102mm(MIN.) \A1;152mm(MAX.) \A1;76.2dmm \A1;63.5dmm \A1;11.1mm \A1;(MIN.) \A1;32mm \A1;(MIN.) \A1;100 \A1;100 \A1;100 \A1;600 (MAX.) \A1;\A1;900 FROM FIN. FLR. LVL. \A1;200 \A1;900 \A1;300(MIN.) (VARIES) \A1;300(MIN.) \A1;300(MAX.) (EVERY OTHER FLOOR) 750 (CLEAR WIDTH) P L A N 100 PIN LUG COUPLING THREADED HOSE JACKETED W/ CHROME TYPE ABC PORTABLE FIRE 10 LBS. DRY CHEMICAL PLATE SHALL BE GAUGE #18 PULL FLUSH MOUNTING DOOR W/ TRIM FOR ALL GLASS W/ NOTE “BREAK GLASS IN E L E V A T I O N CASE OF FIRE” ALUMINUM TRIM EXTINGUISHER ANGLE VALVE AT FLR. LVL. W/ COMBINATION TYPE RESTRICTING 40d ANGLE VALVE W/ EXCEEDING DOWNSTREAM RUBBER LINE COTTON FIRE ADJUSTABLE PRESSURE 40d x 30.00 M. LONG BRASS POLISHED FIRE FOG RESTRICTING ANGLE VALVE PRESSURE OF 100 PSI. ADJUSTABLE NOZZLE FINISH FLOOR LINE (SURFACE MOUNTED) ABC 200\X(CLEAR DEPTH) 750 (CLEAR WIDTH) 100 800 (CLEAR HEIGHT) 900\X(ABOVE FLR.LEVEL) 4 F4-01 DETAIL OF FIRE HOSE CABINET SCALE 1:10 MTS. R.C./CHB WALL SIZE VARIES 25d-LESS THAN 6.0M 32d-6.10 TO 11.90M 40d-12.00M & ABOVE SIZE VARIES 25d-LESS THAN 6.0M 32d-6.10 TO 11.90M 40d-12.00M & ABOVE 1 F4-01 DETAIL OF FE-36 50 LBS.WHEELED TYPE PORTABLE FIRE EXTINGUISHER NOT TO SCALE FIN. FLR. LINE E L E V A T I O N LONG DISCHARGE NOZZLE & HOSE 65 LBS. (29.50 kg) HALOTRON TYPE /OR 50 LBS. (22.7 kg) DRY CHEMICAL ON HEAVY-DUTY STEEL CYLINDER & CARRIAGE (UL LISTED) 110 100 90 80 70 60 40 20 30 50 10 110 100 90 80 70 60 40 20 30 50 10 3 F4-01 DETAIL OF ALARM CHECK VALVE ASSEMBLY (WET TYPE) SCALE 1:10 MTS. MECH’L. GROOVE COUPLING “VICTAULIC” METRAFLEX BRAND OR EQUAL 150MMd FIRE LINE FROM FIRE PUMP CONCRETE SADDLE SUPPORT MAIN DRAIN VALVE (NORMALLY CLOSED) MAIN CONTROL VALVE FIN. FLR. 50MMd DRAIN PIPE TO NEAREST DRAIN OR SUMP PIT RETARD CHAMBER 100MMd FIRE LINE TO SYSTEM TO WATER MOTOR ALARM ALARM CHECK VALVE CHECK VALVE PRESSURE ALARM SWITCH SYSTEM PRESSURE GAUGE SUPPLY PRESSURE GAUGE PIPE BRACKET E L E V A T I O N 75 SCHEDULE OF PIPE BRACKET/BRACING U-BOLT DIA. S E C T I O N LATERAL BRACE VARIABLE 75 ANGULAR BAR HORIZONTAL PIPE (VER. SIZE) 6MM.THK. LONGITUDINAL BRACE E L E V A T I O N EXPANSION BOLTS CONC. SLAB HORIZONTAL PIPE ANGULAR BAR (VER. SIZE) 6MM.THK. 75 65 10 100 75 12 10 PIPE SIZE 50 10 (VER. SIZE) 75 U-BOLT W/ NUTS CONC. WALL BOLTS & WASHERS 6MM.THK. ANGULAR BAR EXPANSION EXPANSION BOLT 50 X 50 10 HORIZONTAL PIPE 50 X 50 65 X 65 12 10 ANGLE BAR 50 X 50 10 50 CHANNEL BAR 6MM.THK. 50 50 EXPANSION BOLTS (VER. SIZE) HORIZONTAL PIPE 50 50 5 7 F4-01 DETAIL OF SWAY BRACINGS SCALE 1:10 MTS. 5 102mm(MIN.)\X152mm(MAX.) 102mm(MIN.)\X152mm(MAX.) TYPICAL SIDEWALL TYPE SIDEWALL TYPE SPRINKLER HEAD “CENTRAL”,”BEST” BRAND OR EQUAL ESCUTCHEON PLATE R.C. WALL 25dmm-50dmm BRANCH LINE PIPE SLEEVE PROVIDED WITH NON-COMBUSTIBLE MATERIAL, MINERAL WOOL OR APPROVED EQUAL FILLED WITH FIRE RATED OR FIRE STOPPING MATERIALS OR APPROVED EQUAL CEILING LINE 6 F4-01 DETAIL OF SPRINKLER HEADS SCALE 1:3 MTS. 76.2dmm 63.5dmm TYPICAL RECESSED PENDENT TYPE TYPICAL UPRIGHT TYPE CLOSURE MOUNTING PLATE 11.1mm\X(MIN.) 32mm\X(MIN.) 25dmm-50dmm BRANCH LINE UPRIGHT TYPE SPRINKLER HEAD “CENTRAL”,”BEST” BRAND OR EQUAL 25.4×12.7mm REDUCER TYPE INSTALLATION GYPSUM BOARD CEILING FINISH RECESSED TYPE SPRINKLER HEAD “CENTRAL”,”BEST” BRAND OR EQUAL 25.4×12.7mm REDUCER 25dmm CLOSED NIPPLE C L BRAND WITH SIGHT GLASS OR FIRE STOPPING MATERIALS OR APPROVED EQUAL FIN. FLR. LINE OR APPROVED EQUAL FILLED WITH FIRE RATED PIPE SLEEVE PROVIDED WITH NON-COMBUSTIBLE MATERIAL, MINERAL WOOL GAUGE CONNECTION LINE 25dITC DL SYSTEM PRESSURE OR FM APPROVED EQUAL 50MMd FCV DRAIN LINE STACK UNION W/ CORROSION 25MMdx90 SPRINKLER ORIFICE OF THE SYSTEM) SIMILAR TO “SURE-TEST” TO THE SMALLEST (GIVING FLOW EQUIVALENT RESISTANT ORIFICE R.C. WALL ELBOW LINE VALVE OR SIMILAR TO 25MMd INSPECTOR TEST 25MMd BRANCH WALL FASTENER 50MMd FCV DRAIN SPRINKLER HEAD 20 220 60 80 40 100 120 140 200 180 160 FIN. FLR. LINE PIPE HANGER LINE STACK 3 F4-01 DETAIL OF INSPECTOR TEST CONNECTION SCALE 1:10 MTS. 100 100 100 600 (MAX.) TO BE FILLED W/ NON-COMBUSTIBLE MATERIAL (FIRE STOPPING SEALANT) FIN. FLOOR LINE PIPE SLEEVE MECH’L. GROOVE COUPLING 100mmd DRY STAND PIPE RISER CHAIN 65mmd CAP 65mmd FIRE HOSE VALVE 100mmd DRY STAND PIPE RISER CHAIN 65mmd FIRE HOSE VALVE 65mmd CAP P L A N E L E V A T I O N PROVIDED W/ FIRE RATED SEALANT \A1;900 FROM FIN. FLR. LVL. 5 F4-01 DETAIL OF FIRE HOSE VALVE SCALE 1:10 MTS. 3MM THICK STEEL PLATE RACKET SUPPORT 2 F4-01 DETAIL OF 10 LBS. (4.5 KG) PORTABLE FIRE EXTINGUISHER NOT TO SCALE S E C T I O N CHB WALL 200 900 10 lbs. (4.5 kg.) DRY CHEM. TYPE) PORTABLE FIRE (HALOTRON OR EXTINGUISHER ABC F.F.L. EXPANSION BOLT 1 F4-01 DETAIL OF SUPERVISORY FLOOR CONTROL VALVE ASSEMBLY SCALE 1:15 MTS. 70 50 40 20 30 10 110 100 90 80 60 FIN. FLR. LVL. 300(MIN.)\X(VARIES) 10 70 50 40 20 30 110 100 90 80 60 300(MIN.) 300(MAX.)\X(EVERY OTHER FLOOR) (TERMINATION BY SPRINKLER CONTRACTOR) 2 F4-01 SPOT DETAIL NOT TO SCALE (BY CONTRACTOR) 140 120 100 20 160 220 200 180 40 60 80 25MMd INSPECTOR TEST VALVE OR SIMILAR TO UNION W/ CORROSION RESISTANT ORIFICE (GIVING FLOW EQUIVALENT TO THE SMALLEST SPRINKLER ORIFICE OF THE SYSTEM) SIMILAR TO “SURE-TEST” BRAND WITH SIGHT GLASS OR FM APPROVED EQUAL 25mmdBALL VALVE TYPE DRAIN VALVE 100Ø FEEDMAIN CONNECTION LINE TO SYSTEM SYSTEM PRESSURE GAUGE AT LOWEST FLOOR LEVEL (FOR DOWNFEED SYSTEM) BLIND FLANGE CONNECTION 150d AFSS RISER AND DOWNFEED 50d FCV DRAIN LINE STACKED TAPPED TO THE NEAREST DRAIN MECHANICAL GROOVE COUPLING “VICTAULIC”, “METRAFLEX” BRAND OR EQUAL PIPE SLEEVE PROVIDED W/ NON- COMBUSTIBLE MAT’L. MINERAL WOOL OR APPROVED EQUAL 150d AFSS RISER AND DOWNFEED 50d FCV DRAIN LINE STACKED TAPPED TO THE NEAREST DRAIN MECHANICAL GROOVE COUPLING “VICTAULIC”, “METRAFLEX” BRAND OR EQUAL BLIND FLANGE CONNECTION SYSTEM PRESSURE GAUGE AT HIGHEST FLOOR LEVEL (FOR UPFEED SYSTEM) INDICATING TYPE FLOOR CONTROL VALVE W/ SUPER- VISORY SWITCH SYSTEM PRESSURE GAUGE WATER FLOW SWITCH ELECTRICAL JUNCTION BOX (BY EE WORKS) ELECT’L. CONDUIT TO FIRE ALARM CONTROL PANEL (BY EE WORKS) ELECTRICAL JUNCTION BOX (BY EE WORKS) FIRE ALARM SYSTEM (BY CONTRACTOR) 8-#16 TW WIRE IN 15 MM d IMC PIPE TO FIRE ALARM CONTROL VALVE (BY CONTRACTOR) CONTROL VALVE WITH SUPERVISORY TAMPER SWITCH (BY SPRINKLER WORKS) FIRE ALARM SYSTEM (BY CONTRACTOR) TAPPING POINT (BY SPRINKLER WORKS) 4-#16 TW WIRE IN 15 MM d IMC PIPE (BY CONTRACTOR) SYSTEM PRESSURE GAUGE FEEDER MAIN PIPE SUPERVISED FLOW SWITCHES (BY SPRINKLER WORKS) 4-#16 TW WIRE IN 15 MM d FLEXIBLE CONDUIT FROM FLOOR CONTROL VALVE (TERMINATION, BY SPRINKLER WORKS) 4-#16 TW WIRE IN 15 MM d FLEXIBLE CONDUIT STUB-OUT
or get unlimited access from $7/mo