Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Group Of 10 Appartments DWG Section for AutoCAD

Complete planes of 10 appartments – Building in 3 levels – 2 bedrooms – Plants – Sections – Details – Installations

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

irrigation key., thn, buoy type valve, water meter, bn, coffee, retention valve., flexible union., foot valve type retention with incorporated pascon, potable or hot water connection to cabinet, drainage floor with siphon, with indicated d and grill lid in polished bronze., cold water column with dy number indicated, pump, number indicated., gate valve., downpipe., hydropneumatic tank., floor register for sewage , with polished bronze lid indoors or plug, discharge of sanitary furniture or similar in floor or wall with indicated d., mechanical symbology, pvc threaded outdoors., record for black water in sky., snpt, cv-n, ban- n, above level of finished floor, structural element, hoop, longitudinal steel, liquid level, concrete lightened, variable, angle frame, red, lid with angle, connect to collector, plant, concrete cover, pvc pipe , registry detail siphon, scale :, registry detail black waters, the inst alacion drivers, all output on the wall must carry metal box, electric conductors must carry visible marks of the factory, pipes in floors and mezzanines must be dried and cleaned before, should be at least an access to the ceiling ., be solidly grounded, be protected against rain, from layers of electrical tape, electrical notes, with cover and connectors, curves, joints and galvanized gauze to hold, joints will only be accepted in register boxes with a minimum, the metal boxes of boards and switches should, the earth rod should be outside the construction, and where it is installed should be in registry with t., the electrical installation should go in pipes, use boxes of record , the meter should be accessible for reading and furthermore, all metal boxes should be attached to the pipe by means of connectors, the maximum depth of the outer edge of the wall boxes will be of, the eria., wiring for receptacles, wiring for lamps, special output kitchen and thermowell, incandescent lamp output, wiring lamp switch, output for reflectors, single or multiple damper, double outlet, telephone outlet, TV antenna output, electrical symbology, thermomagnetic distribution board , current input breaker box, kwh meter, complementary accessories, the contractor will supply all those accessories not expressly indicated in drawings but that are necessary for a correct placement of the metal structure., all measurements will be verified on the site before proceeding to the manufacture of the structures, according to the geometries given in the plans. Any doubt in the interpretation of the plans must be evacuated in advance with the professional inspector of the work, will not accept parts that in the opinion of the inspector are deficient in their quality of manufacture and assembly., verification d e measures, size of the electrode, steel profiles, notes for metal structure, welding, profile, thickness, inch, profile gauge, structural steel, section, amperage, structural notes, terrazzo, angular, hooks, wall, beam, npt, go, handrails, earth rod, connected to the neutral, main switch, type conduit, tails, flashing, distribution box, v. crown, vce, v. banquette tapichel, up, down, yard, board g, with additional ground bar to neutral bar., consumption, estimated demand, total potential, bars, total, circuit, description, amp, voltage, power, protection, total current, driver , amps, breaker, type, thhn, gauge, conduit, phase, lighting, sockets, sockets, kitchen, thermocouple, board h, board i, board j, comes drinking water, connection to, ts and fafa, existing sewer, rises potable water, firm ground, ground, downspout, hua flask, sewage, rain, compacted ballast, bathroom, sky in gypsum, ceramic floor, rectangular profile, run plate, bedroom, stone fifth drainage, concrete poor to channel rainwater, buttress, nidia murillo rojas, vocational college, virginia peñaranda hernandez, noemy ruiz fields, sidewalk, room, ce, gyp, batteries, architectural plant table of finishes location location, apartments, leonel red alvarez, owner: , province, heredia, professional responsible technical direction, responsible professional design, n cadastre :, content, scale, real folio :, indicated, name :, file :, signature :, project :, drawing: fas, sheet, date, information of the public registry, construction plans, central office for the visa, district, canton, permit number, ing. jose alvarez salazar, ing. austin shen ti, power plants electric notes electric power lines electric symbology, structural and mechanical plants structural notes structural notes steel mechanical symbology detail closure aros, pplanta de tec

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Section
Category
Additional Screenshots
File Type dwg
Materials Concrete, Steel, Wood, Other
Measurement Units Metric
Footprint Area
Building Features Deck / Patio
Tags , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Startland Construction

Leave a Reply

ADVERTISEMENT