Metering Box Re Transforer 45kva DWG Block for AutoCAD

UNDER MEASUREMENT OF NICHE positioned relative to 45 KVA TRANSFORMER DESIGN FOR PRACTICAL USE.

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

danger, high voltage, Niche metering arrangement with general switch, Location of kva pedestal transformer, cut, Construction specifications dimensions in centimeters. The reinforcing steel will be rod all the concrete f’c kpa t.m.a. All the concrete will vibrate to achieve proper compaction. The coatings will be minimal. The concrete will have finished apparent in the common interior in the exterior. For marine environment salty soils should be used cement type according to the norm nom brick should be light type. The maximum distance between mooring lines should be for the reinforcement grid. The assembly grille must respect the assembly rods. The ties shall be made with annealed lime wire., Description a. Connection of tips in the low voltage nozzle in kva transformer. B. Aluminum conduit type c. Conduit pipe conduit for pvc wiring awg awg wires. D. Connected three – phase connector equipment a. and. Pvc conduit pipe bridge. F. Cabinet nema mod. Mca with thermomagnetic switch of mod. Mca, Transformer neutral must be ground as, For larger conductor gauges mm will be used, Distinctive colored legends placed at both ends of the, Any other color except the previous ones, You must use the color code for drivers using:, Using approved connectors of sufficient size., Must be effectively connected to the laying conductor, Land whose caliber should not be less than that of the table, Records anywhere associated with the system, The metal cabinets of, in the section, Tories., White Grey, Naked green sunset, Contactor must be identified with, Fixed legend according to the designation of the project., Project will be carried out on the basis of the, The material equipment used in the electrical installation, Mexican official, Certified by approved accredited bodies, section, Value of the system ground resistance should not be greater, Notes:, Should be validated for each case by a, Verifying unit of electrical installations., N.p.t

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Aluminum, Concrete, Steel, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

CAD Drawings

Leave a Reply