Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Electric Details DWG Detail for AutoCAD

Details of electricity – Road post – Phone installation for residence – Installation antenna TV – Etc.

Drawing labels, details, and other text information extracted from the CAD file:

drawing no.:, sheet no.:, approved:, date, lic.no., date, title:, project no.:, drawn by:, date:, scale:, submitted:, lic.no., call box old san juan station tetuan san, puerto rico tel. fax., cadd file no., plot date:, lebron, associates, amp. poles raintight, raintight., panel riser diagram, n.t.s., pvc conduit, xlp in, to service pedestal, copperclad, ground rod, ground clamp, rgs conduit, with control wires, magnetically held with key, finished grade, ground wire, bare copper, amp main circuit bkr, with ground, volts, facing north, photocell, panelboard, see schedule, lighting contactor, panel, scale, number, circuit, trip, branch breakers, voltage, mounting, and location, designation type, panel schedule, capacity, type, poles, lighting fixture schedule, surface, ceiling mtd., wall, nation, type, description, kenall, manufacturer, series, series, cat. no., lamps or tubes, number, watts, twin, tube, type, remarks, section, not to scale, pvc yellow, spacer, pvc sch., conduit, conduit base, note below, sand bed see, warning ribbon, well compacted stone, finished grade, free earth, lighting fixture schedule, cat. no., series, dim, nation, wall mtd., stems mtd., surface mtd., recessed, stems mtd., wall mtd., day brite, kennall, metalux, kennall, metalux, daybrite, recessed, type, description, manufacturer, daybrite, metalux, daybrite, lamps or tubes, watts, number, type, volts, remarks, volts, contactor schedule, cont., no., designation, m.h., remarks, controlled, circuits, size, nema, poles, total, spare, active, m.h., type, full scale, full scale txt, gfi, min., provide long wire tail, for t.v. lighting arresters, tw grounding conductor, t.v. riser diagram, conduit rod, rod bronze ground clamp for, copper weld ground, floor, galv. conduit, tw in rigid, rised cover telephone plate, junction box with, conduit, conductor in rigid galv., tw grounding electrode, roof, ground clamp, to ground, conduit to be connected, connector, ground, conc., entrance cap, type, min., floor, roof, entrance cap, pvc conduit sch., emt, box with one gang, cover plate, box with, telephone plate, aff, telephone diagram, alambres en conducto de rigido, nivel de terreno, c.c. a.d., c.c. a.d., pedestal, diagrama monolineal, no escala, conducto de pvc sch., planta electrica, barra de bronce de, abrazadera de bronce, alambre tierra rhw en conducto de, base para contador, alambres thw conducto rigido, conduleto tipo, leyenda, tejas, telefono, cable t.v., electrico, caja de cable, caja de telefono, con main de amps., panel federal de circuitos, caja de cambio de, electricidad planta, min., minimo, associates, lebron, dia unless otherwise indicated., all conduits burced under ground or inside concrete slab shall be, minimum unless otherwise indicated., all exposed conduits shall be rigid galvanized steel, run inside all conduit runs., an additional gren ground conductor shall be, contractor shall coordinate all his work with existing facilities and with, owner’s engineer or owner representative before proceeding., information on these drawings shall be field coordinate and verified., contractor shall visit the project and report his comments before bidding., any difference between plans and specifications and or plans and field, conditions must be brought to the attention of the engineer., contractor to submit for approval all conduits and, receptacles and any other electrical material required for the, project., power factor for all equipment to be above required by the puerto rico, energy code., all equipment and materials must be new and as per nema and u.s. standards., all directories must be clearly marked and filled., no type conductor will be allowed., minimum conduit size to be diameter. use rgs conduct or as shown on, plans., minimum conductor size must be thhn copper volts., the contractor shall repair all existing concrete work if damage is done, during installation of conduit and or equipment., general notes:, sc.:, lrp, t.v. diagram, way, conduleto tipo, cable conductor, concreto, en conducto galv., de ground electrodo, con plato para tel., caja cubierta, conector de ground, ground, conectarse en, cable t.w., conducto, min., varilla de cobre, no escala, nivel de piso, diagrama t.v., fuera del, de largo, de ground para t.v., cable t.w. conductor, techo, seccion, hacia toma telefonica, plastico, varia, panel, hacia piso, no escala, conducto rigido, grapa, terreno, contador, conducto, rigido, varilla de cobre, pedestal, vars c.c., rigido, conducto, caja pvc., amp. combinado, amp. alumbrado, amp. receptaculos, amp. estufa, amp. calentador, panel, amp. secadora, amp. nevera, amp. receptaculos, amp. alumbrado, opcion, amp. lavadora, tubo, voltios, amperaje, alambres, polo, usos, estufa, clst. bano, nevera, sala comed., walk in sala, comedor family r., laundry clst., sala bano, garage, panel de circuitos, circuitos, circ, opcion, secadora, lavadora, circ, calentador, circ, r.w.h., r.w.

Raw text data extracted from CAD file:

Language English
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Aluminum, Concrete, Plastic, Steel, Other
Measurement Units
Footprint Area
Building Features A/C, Garage, Car Parking Lot, Garden / Park
Tags , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

CAD Drawings

Leave a Reply