Cottage Restaurant DWG Block for AutoCAD

RESTAURANT RURAL

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

booth, high stainless steel furniture projection, projection, living, stage, sound, trade, ss.hh, deposit, yard download, cold room, washing and cleaning, washing dishes, trade, dep. gen., warehouse, yard maneuver, bar snack, g.e., house of force, lavander., patio, restaurant, washing of sweets, of preparation of sweets, washing of salted, prepared of salted, served, service, dep. gardening, dep. cleaning, kitchen, meters, t.g, deposit bottles, dep. furniture, bas., dressing rooms, attention bar, vest., overlapping splices, columns, steel rods used in the construction of structures, reinforced concrete, meet the requirements established in the minimum diameters of seamless bending :, it should be noted that the rods to be used present their surface, free from corrosion, cracks, welds or any other defect that could adversely affect their mechanical characteristics. Reinforcing steel:, before using the reinforcements, they should be carefully cleaned so that find free of dust, mud, oils, paint and any other substance capable of reducing adhesion with concrete. To support or fix the reinforcement in the corresponding places, use metal or mortar supports or spacers and metal ties, can not be used pieces of brick, wood, or cane, or particles of aggregate., placement of the reinforcement :, preparation and placement :, coatings of The effort :, means coatings at the free distance between, the most protruding point of any reinforcement and the external surface, of the nearest concrete, excluding tarrajeos and all other material, of finishes., structural element coating of the reinforcement, Coatings will be achieved through the use of dies, concrete or mortar, dimensions of the coatings, beams and beams, structural columns, columns of albanileria, the required joints will be executed by overlap, in the areas, indicated in the plans. , the rods spliced ​​by means of overlaps shall comply with the following dimensions: the minimum separation between individual and parallel straight rods of the armor, outside of a joint zone, in general shall be, thick., joints in the reinforcement, separation between rods:, special care should be taken to the correct placement inside, of the formwork of all the indicated irons Other elements that should be embedded in the concrete, these elements must be well insured and avoid so, move during the process of placement of the concrete, the formwork should be sufficiently waterproof to prevent loss of grout or mortar ., the internal face of the formwork should be clean and free of different particles., the minimum time of removal of the formwork and elements of, sustain, will be regulated by the following times :, formwork and formwork :, characteristics of the formwork: , unit of albanileria :, the unit of baked clay masonry, will consist of elements, perforated, being these perpendicular to the face of the seat., will not accept cracked, fractured units, with slits, mortar :, the mortar will be constituted by cement portland and coarse sand ,, labor:, will be qualified fulfilling the following basic requirements :, – walls built to lead and in line., – joints horizo vertical and completely filled with mortar, – masonry units seated with clean surfaces and without, free water., removal of formwork, execution and quality controls for masonry, components: structural design criteria, manual design aisc, a- codes and standards used, b- design loads, foundations, d- quality of materials used :, – portland ms type, – resistance to breakage by compression of the unit, – resistance to Breakage by compression of the wall, beam, level of formwork, column, length of joint cm., constructive specifications, projected depths, column, plate or beam, detail of bending of stirrups, columns and beams, typical detail of lightened , detail of lintels, elevation, table of lintels, recommended areas for the overlap of reinforcement run in beams and joists, upper reinforcement, reinforcement inferiror, h any, traction, value sdem, compression, overlaps and splices, columns, beams, slabs, will not be allowed, abutments, rmax, same section, armor in one, no more splices, central third, will be located in the, the l, the column or support , beam on each side of, of light of the slab or, joints of the reinforcement, columns, slabs and beams, delivery of joists, column on, delivery of, column, existing, roof, new, center, corner, beam on beam, with existing, splice of, new column, project:, owner:, specialty:, proyectis

Raw text data extracted from CAD file:

PREMIUM

File Details

File Type
DWG
Type
Block
Language
Spanish
Materials
Concrete, Masonry, Steel, Wood, Other
Units
Metric
Features
Garden / Park, Deck / Patio
Uploaded by
Eng_Plans
Category
Hotel, Restaurants & Recreation
Published
Dec 12, 2017
Price $3.87
or

or get unlimited access from $7/mo

Browse All Downloads