Two Family House DWG Block for AutoCAD

It appears in the first level a multipurpose room, with restrooms kitchen and bedroom, the entry to the second level is independent from the street which has a bedroom with restrooms and a private kitchen and three bedrooms with restrooms Common

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

– thermomagnetic switches and differentials, – door and sheet, finished with hammered paint, – wall-mounted box, metal type, distribution board, cover, switch, sheet, thermo-magnetic board, non-scale, thermomagnetic, metal, ldg, d stirrups, considering zone of, high efforts but, that are less spliced, joint in columns, detail, column, beam, note:, detail of beam – column encounters, elevation, according to type, detail of beams meeting, plant, concrete simple, reinforced concrete, shoes and vig. foundation, columns, beams and slabs, materials, corrugated steel, cement, masonry, coatings, footings, foundation beams, columns and beams, columns braces, flat beams and slabs, technical specifications, flooring, sub-footings, foundation corridos, sobrecimientos , porland ip type, shower, kitchen, sum, ss.hh., floor:, kitchenette, bedroom, roof, main elevation, bb cut, cut aa, cc cut, typical detail of column anchor with foundation, according to table stirrups, npt., column, typical detail, additional stirrups, variable, see detail, steel according to the type of column, given concrete, both directions, see table of stirrups, detail of splicing of columns, considering area of ​​stress low, splice longitudinal steel of columns trying to make said joints outside the confinement area, note: foundations:, characteristics of the confined masonry:, thickness of mortar joints, volume, if it has alveoli these , minimum thickness, design and construction specifications: after the stripping of the roof, with a tambourine brick, the non-load-bearing walls will be raised to their total height, the reinforced walls are load-bearing and will be made of brick, observations: earthquake resistant design, national regulations of constructions, minimum anchor lengths and reinforcement overlap, overlaps, ladder, anchor, overloads:, flat beams, banked beams and columns, stairs and lightened, technical specifications, concrete cyclopean, scale, total, note : the length provided will be the minimum placed at the time of construction, type, frame of stirrups, detail of, detail of continuous foundations, beam c. see detail, finished, level floor, foundation beam, width, length, detail of grate in shoes, foundations, ds of lightened., temperature steel, temperature steel place in the middle, place concrete dies or separators, steel negative, steel positive, frontal elevation of parapet roof, typical detail parapet roof, q – q, beam or v.ciment., lateral elevation, npt, detail of beams, vp, v-ch, vb, lightened, panel of distribution embedded, npt, height, watt-hour meter, outlet for spot light, outlet for wall lamp, ceiling box or wall, general board, circuit for cable – tv, intercom duct, number of cable per circuit, description, circuit in duct embedded in the ceiling, circuit in duct embedded in floor or wall, exit for ceiling-mounted lamp, double single outlet, symbol, _____c_____c____c__, legend, well to ground, single and double unipolar switch, switching switch, output for tv – cable, output for direct telephone, intercom, intercom push button, outlet for electric heater, outlet for gas duct, type for ticino or similar with plastic plates magic series, galvanized iron cabinet for flush with frame and door metallic, and posts that will be pvc-sap, standard sized galvanized iron boxes for embed light type, switches and receptacles, fittings that are inside the pipes, pipes, boxes, all the cunductores will be continuous from box to box. will not be allowed, technical specifications, conductors, reinforced concrete cover, pvc-p pipe, conductor, grounding, bronze connector, copper electrode, bare conductor, sanik gel, sulfate, magnesium or similar substance, det . from well to earth, sifted earth, and compacted, pressure connector, aerial, telephone, connection, copper or bronze, proy. Valve box, hot water outlet, drain, cold water, outlet for, exit from, on the floor, alternative outlet, drain outlet, det. of water outlets and, drain in toilets, inst. sanitary, inst. electrical, socket, lighting, electrosur, kw-h, unifiliar diagram of the general board, reservation, cross section, zz, or masonry, bottom level, brick, see, level of cover, the same material, finished floor, two handles, iron cover: iron, cover box of record, reinforcement pl, iron plate, see floor, or brick masonry, detail: register box, installation of valves, typical detail of:, pvc adapter, union thread, npt, valve, frame and wooden cover, with hinges, pvc drain network, sump, blind box, register box

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Plastic, Steel, Wood, Other
Measurement Units Imperial
Footprint Area
Building Features
Tags , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,