Cat Ladder, High Tank Inspection, Water Cistern DWG Block for AutoCAD
Design a cat ladder; When used in a pump room for the inspection of the level of water from a cistern.
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
scale, section, see detail, Units: length in diametres in, Cape, Arrival quota in, See location of the flat, legend, item, description, Cant, Quick connect coupling adapter, Quick connect coupling, Cuff bb, Bc hfd transition to pvc, chain of, Baby elbow, Pump model, Flange breaks water in pipe, scale, section, Anchoring sleeve, Cuff bb, Bc transition for pvc, Of bolt to bolt the wall with bolt hilti type kbii, Bracket for bolting with hilti bolt type kbii, Fixed coupling for horizontal section pipe, Sliding coupling with teflon ring for quick disconnect system, The pipe is used in the pumping chamber for drainage, Will be made of galvanized carbon steel, The emergency pump pump will be of characteristics, Similar to those of electric pumps, Suction hoses download seran de, In hot., The end of the discharge line of the motor pump, Must have the necessary addition for its union to the, Quick coupling considered in the pumping chamber, Drainage detail, Cuff ee, Flange breaks water in pipe, elbow, Lifting system for submersible electric pumps, The supports of each submersible electric pump rest, On the bottom of the pumping chamber of drainage., For structural details of the pumping chamber of, Drain staircase see civil plane., The lifting system for the withdrawal of the submersible electric pumps corresponds to a drive line whose parts are indicated in the attached diagram and can be of the same itt mark that meets the requirements of the design. For the entrance of the electric pump the cbd should proceed the following: install a portable key on the area of the inspection cover. With the use of the chain the drive assembly must be entered by the projected drainage pumping chamber ensuring that the flexible coupling engages the guide rail. Lower the electric pump until it rests on the bottom slab of the generating the sealing of the joint between the fixed couplings sliding through the teflon ring. To remove the electric pump from the cbd, proceed as follows: manually suspend the operation of the electric pump to be removed from the cbdp. Close the pump valve of the electric pump to be withdrawn. Install the portable key on the inspection cover. Remove the drive assembly by using the slide assembly until the slide engages the guide rail and leaves the assembly through the opening in the cover., Model for itt mark pump similar, Lifting system for submersible electric pumps, Notes:, Guide rail, legend, item, Electric submersible pump see box, description, Cant, Threaded sleeve, Threaded reduction, Threaded sleeve, Threaded elbow, Cuff be, Flange breaks water in pipe, Flange bolt in tubing, Cuff be min., Self-supporting dismantling union hfd, Valve check bb hfd, Gate valve bb hfd, Baby elbow, Cross bb, Cuff be, Technical specifications, Pumping chamber for drainage installation Hydraulic sheet, review:, Be left on the formwork, Anchor steps, corrugated, Sea ladder, detail, elevation, welding, Corrugated will be left in the formwork, Be left on the formwork, section, detail, plant, Inspection window, anchorage, Steps, tube, It will be left, In the formwork, tube, Detail: cat stair, Esc .:, elevation, plant, see detail, section, Esc .:, It will be left, In the formwork, welding, anchorage, Corrugated, In the formwork, detail, Esc .:, Esc .:, Abbreviations, The use of electric pumps will be considered whose basic electrical hydraulic characteristics are the following: pumping flow rate …………………. total dynamic height …… ………… operation ……………………….. alternate, Technical specifications, Aaa, High level wastewater alarm, Level for pump start, Level to stop the pumps, Level for pump start, Aba, Low level wastewater alarm, Mailbox number, Pumping chamber for drainage installation Hydraulic sheet, review:
Raw text data extracted from CAD file:
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
scale, section, see detail, units: length in diameters in, cape, arrival quota in, see location of the flat, legend, item, description, Cant, quick connect coupling adapter, quick connect coupling, cuff bb, bc hfd transition to pvc, chain of, baby elbow, pump model, flange breaks water in pipe, scale, section, anchoring sleeve, cuff bb, bc transition for pvc, of bolt to bolt the wall with bolt hilti type kbii, bracket to bolt to hilti bolt type kbii, fixed coupling for horizontal section pipe, sliding coupling with teflon ring for quick disconnect system, the pipe used in the pumping chamber of drainage, will be made of galvanized carbon steel, the emergency pump pump will be of characteristics, similar to those of electric pumps, suction hoses download seran de, In hot., the end of the discharge line of the motor pump, must have the necessary addition for its union to the, quick coupling considered in the pumping chamber, drainage detail, cuff ee, flange breaks water in pipe, elbow, lifting system for submersible electric pumps, the supports of each submersible electric pump rest, on the bottom of the pumping chamber of drainage., for structural details of the pumping chamber of, drain staircase see civil plane., the lifting system for the withdrawal of the submersible electric pumps corresponds to a drive line whose parts are indicated in the attached diagram and can be of the same itt mark that meets the requirements of the design. for the entrance of the electric pump the cbd should proceed as follows: install a portable key on the area of the inspection cover. with the use of the chain the drive assembly must be inserted into the projected drainage pumping chamber ensuring that the flexible coupling engages the guide rail. lower the electric pump until it rests on the bottom slab of the generating the sealing of the joint between the fixed couplings sliding through the teflon ring. to remove the electric pump from the cbd, proceed as follows: manually suspend the operation of the electric pump to be removed from the cbdp. close the pump valve of the electric pump to be withdrawn. install the portable key on the inspection cover. remove the drive assembly by using the slide assembly until the slide attachment is released from the guide rail and the assembly comes out through the opening of the cover., model for pump mark itt similar, lifting system for submersible electric pumps, Notes:, guide rail, legend, item, electric submersible pump see box, description, Cant, threaded sleeve, threaded reduction, threaded sleeve, threaded elbow, cuff, flange breaks water in pipe, flange bolt in tubing, cuff be min., self-supporting dismantling union hfd, valve check bb hfd, gate valve bb hfd, baby elbow
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Block |
Category | Stairways |
Additional Screenshots | |
File Type | dwg |
Materials | Steel, Other |
Measurement Units | |
Footprint Area | |
Building Features | Car Parking Lot |
Tags | autocad, block, cat, cistern, degrau, Design, DWG, échelle, escada, escalier, étape, high, inspection, ladder, leiter, Level, pump, room, staircase, stairway, step, stufen, tank, treppe, treppen, water |