ADVERTISEMENT

ADVERTISEMENT

Cooling Details DWG Detail for AutoCAD

Cooling Details – Cooling tower – Air duct

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

pending, Insulation of exposed duct exposed mechanical abuses, expanded metal., cement., Vinyl painting, Connections., Fiberglass insulation, Foil of adhered aluminum, Kraft paper adhered one layer., Adhered cm thick, Sealing eliminates in ducts, Air heating, Ducts without insulation, Should be sealed in all their, Galvanized sheet duct., Coat sealer., Over duct of, Outer sheet, fiberglass, Duct, Sealing layer, paper, Insulation of exterior ducts, Tailstock, Unit pack, See details of it, Drain connection, Faith angle of, Drain connection, drain, equipment, Mm, Neoprene, Heel of, Steel plate, Mm, Faith angle, Dimension pipeline, lime. No width mm, Slab support, Dicks, Mm expansion bump, With pressure washer, Faith angle of mm., Horizontal duct., Support for external horizontal ducts, Galvanized sheet belt, slab, galvanized sheet, lime. do not., Threaded stud with, Mm nut, Staple, Duct support, S., Of mm each m., Of expansion., Strip of lime., Vertical duct., Pijas, Bolts with lugs, In cm maximum, The figure will be used for ducts, Of minimum cm, Faith angle of mm, For ducts of minimum cm., For ducts of maximum cm., Faith angle of mm, Support for vertical ducts, Waterproofing, of thickness, Fiberglass insulation, Parapet for botaguas, Black sealant, By others, Base coat of, Asbestos cement with fabric, From chicken coop for, Weather permitting by others, lime., Lamellar galv., Rectangular outside, Pipes in ducts, Major side, For ducts smaller than cms., For ducts greater than cms., Interior duct support detail with unlined, note:, slab., Not long mm., Maximum space between mts., Threaded bolt with mm turecas, With pressure sheave, Galvanized sheet lime., Expansion pack., Faith angle of, Mm round iron, Mm wide, Galvanized mm nut, Insulation of exterior ducts, paper, Sealing layer, Duct, fiberglass, Outer sheet, Over duct of, Coat sealer., Galvanized sheet duct., Should be sealed in all their, Ducts without insulation, Air heating, Sealing eliminates in ducts, Adhered cm thick, Kraft paper adhered one layer., Foil of adhered aluminum, Fiberglass insulation, Connections., Vinyl painting, cement., expanded metal., Insulation of exposed duct exposed mechanical abuses, pending, Insulation of interior ducts, fiberglass, Duct, Galvanized, Sheet duct, Rf of thickness, paper, With sealant, fiberglass, adhesive, Outlet diffuser., Wood zoclo., Axial blade., Circular cover., Detachable cap., Mushroom fan installation, Structural supports., Duct., motor., Vibration isolators., Waterproofing., Conduit pipe, post, slab, Fixing plate, Mmd pack, Electric register, Detail of ceiling fan assembly, Suction pump, Spring pendant, Differential pressure gauge, Suction diffuser, gate valve, Multipurpose valve, Suction pipe, Discharge pipe, Multipurpose pump connection, On roof of house of machines, At home, Comes from ugar, In house of maqs., Low pumps, Location of cooling towers, Multi-zone refrigerated water coil connection, Refrigerated water coil connection in unizona, note:, thermometer, Gauge preparation, gate valve, Frame valve, Female cap, Each quarter of equipment after the, Isolating valve, Cooling water supply, Cooling water return, Valve for air purge, Union nut, A water filter will be installed to, note:, Union nut, Frame valve, pressure gauge, Three-way valve, gate valve, Female cap, Cms., Thermometer preparation, Cooling water return, Cooling water supply, Valve for manual air vent, A water filter will be installed to, Every quarter after the, Isolating valve., Cm., Return water., To drainage., trap., times, Tee times, Purge line mmd, Expansion line, Mmd vent., Removable cover., float., Overflow mmd., reduction., Open type expansion tank connection, Float valve, Spare water mmd., gate valve., Symbology, 2 step water temperature control, Fan starter, Cooling tower, condensation, Return water from, Condensation water, Extractor duct, Asbestos packing, manhole cover, fire, against, gate, Fat trap detail, Self-tapping screw, soldier, Galvanized pipe, Extractor duct, Registration for cleaning, Black sheet extraction duct lime. Welded, Fire damper, Slope of the grease drainage duct, Extractor hood

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Aluminum, Glass, Plastic, Steel, Wood, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , ,

ADVERTISEMENT

CAD Drawings

Leave a Reply

ADVERTISEMENT