Details Foundation DWG Plan for AutoCAD
plan details based foundation footings and isolated, with girder connection details league shoes, specifications, notes.
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
lock, lock, lock, lock, commercial, to the public, agency, training, of computing, personal agency, npt, npt, npt, min., min., min., minimum, min., min., min., min., contratrabe, wall of enrase, var, cm. of thickness, of partition, chain, to level up to n.p.t., var. cm., running shoe, barbeque with var. cms. in both t.m.a. simple concrete template, in both ways, min., contratrabe, wall of enrase, var, cm. of thickness, of partition, chain, to level up to n.p.t., var. cm., running shoe, barbeque with var. cms. in both t.m.a. simple concrete template, in both ways, min., contratrabe, var, var. cm., running shoe, barbeque with var. cms. in both t.m.a. simple concrete template, in both ways, min., var. cm., isolated footing, column, barbeque with var. cm, concrete template, notes specifications, all dimensions in the dimension governs the drawing., check the reference planes for your complement., foundations:, general, topographic project., the levels shown in the fence profiles refer to the survey, to move on firm ground compacted to that of his p.v.s., the reinforcing steel will be of greater diameter for, the diameter of the reinforcing rods are indicated in inches., limit structure, the diameters are given in centimeters., no one will be allowed in the same, section of the rods, cut, max., welding, there are of, length., note: for rods, only, reinforcement details table, num., diam., I lie, nom., diam., real, diam., weight, nom., area, pzas, do not. of vars., specified, column, cm., cm., cm., specified, concrete tests must be taken at least once for each day of, but at least one for each sample consists of cylinders, supervisor dro for your application., the additives used in the concrete will be subject to the approval of the, the contractor must demonstrate that the additive used maintains the same, behavior in addition to the fact that the product is, used for proportions of concrete to furnish., the quality of the materials., the concrete use must comply with the corresponding laboratory tests, referenced by location cast day for your test, days one of the reveniment will be done once for each delivery, if it is premixed once per revoltures if it is made in the, tolerances according to the requested slump will be:, mm mm, less than, higher, the sketches structural details are not scale., concrete, dosed by mechanical vibration by immersion., the maximum size of the aggregate shall be of volumetric weight of, in case of being done on site, the analysis of water, additives to determine the adequate proportion to obtain the resistances, general characteristics of structural concrete use:, element f’c elaboration type coating resale, standard pumpable pre-mixed shoes, counter pre-mix normal cm pumpable, template in normal work, lock pre
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Plan |
Category | Construction Details & Systems |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Plastic, Steel |
Measurement Units | |
Footprint Area | |
Building Features | |
Tags | armor, autocad, base, based, connection, details, details of foundations, DWG, footings, FOUNDATION, foundations, fundament, girder, isolated, league, plan |