ADVERTISEMENT

ADVERTISEMENT

Details Plinth DWG Detail for AutoCAD

FOUNDATION Isolated footing; armed and representation

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

esp, enducted, total, prefabricated column, firm compression, armed with continuity, lock stiffness, trainee carrier tpi, slab, double slab detail, est in, chain, vars, vars, castle, vars double staples, column, column, vars vars double staples, contratrabe, given without scale, vars double staples, staples, nonstop temperature nerve, welded Mesh, boulder skirting board with cement mortar sand lime, detail of skirting board, tepetate ground, masonry base wall deflection, lock, lock, rest, welded Mesh, typical slab cut without scale, welded Mesh, light filler, tray detail of non-scale installations, parr., dice, plant without scale, concrete template, parr., dice, raised shoe, shoe plant, dice, parr., concrete template, parr., dice, raised shoe, concrete template, run up shoe, concrete template, run up shoe, concrete template, parr., dice, raised shoe, dice, parr., concrete template, dice, non-stop lifting shoe, shoe plant, dice, parr., shoe plant, dice, parr., shoe plant, dice, parr., shoe plant, dice, parr., enclosure chain, column of, enclosure chain, common red wall wall, chain, stone masonry breaststroke, template of poor concrete cm. thickness, cm sole, enough so that no, according to the plans that are totally subject to, before casting it should be checked that all steel has been placed in place, with an apparent elastic limit unless specified, all specified steel of diameter greater than the number must be high, in good conditions. if it is judged, tests will be carried out on dubious steel., immediately after its arrival the work will be checked that the steel is found, reinforcing steel should be protected during, a dala of maximum height should be placed., another different. for the number will be, for the purpose of quality control of concrete on site should be, specimens to be sent to the laboratory to verify the, which should not vary by more than that obtained for, the laboratory specimens., these points will be suitable for this purpose., it shall be avoided to overlap in the area of ​​attachment or a distance, it is forbidden to overlap the reinforcement in the clear centers of horizontal elements, oxidize any other substance that may reduce its adhesion to the concrete., when casting the steel should be free of, allow movements of possible importance during casting., such as slabs. for the case of vertical elements like walls columns, of twice the effective cant in horizontal elements especially trabes., when they are able to support them in their entirety., the manufacturer must take these charges into account, horizontally anchor the given length in the table of, the rods terminated at their ends with a, anchor the length given in the table of, longitudinal reinforcement sufficient pitch for perpendicular reinforcement.

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel, Other
Measurement Units
Footprint Area
Building Features
Tags , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT