Horizontal Tank Cover And Stand And Support Cover DWG Block for AutoCAD
COVER AND SUPPORT DIESEL TANK HORIZONTAL UL42
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
Xxx, Building construction, Notes:, This plan contains information owned by petroamazonas e.p. It is expressly forbidden to copy its use without written authorization of petroamazonas e.p., General notes, date, reviewed, General approval, Ing. draft, Ing. design, cartoonist, Engineering registration design, firm, M.c., to the., C.ch., number, Reference drawings, description, Rev., Revisions, date, drawing, revised, Approved, scale, size, Rev., drawing, description, client, draft, sheet, None, Emergency vent, M.p., Includes blind flange, Vent goose neck, M.p., Overflow, Cplg, Lsl lsh, Screwed bar, Outlet, M.p., Head, Drain, Return, M.p., Shell, Inlet, M.p., Head, Manhole, Qty, Service, Size nps, Location, Observe, Mark, Accessories list, Angle, Cplg, Shell, Head, M.p., Screwed bar, Top view, Manhole flange, scale, hydrostatic test, Corrosion allowable, Mm head tank body, Operating pressure, Atmospheric, design temperature, rated capacity, Gal., length, Operating temperature, diameter, code, Design pressure, Atmospheric, Wind speed, Product store, diesel, Earthquake, Seismic group no. Iv according to the nec, Inspection of welded joints, Spot x-ray, Design conditions, protection, Internal surface preparation, Sigma novaguard eps epoxy phenolic, Sigmaguard eps epoxy phenolic, Sigmacover mils, Sigmafast mils, External surface preparation, Sigmadur mils, Psig as required by, Ral, the UL, Tank weight accessories, Kg., Weight supports, Kg., Heads, Type, Appendix, Diameter Nominal, Nominal capacity, Design pressure, Edition, Serial no., Fabricated by, Service, Year built, Shell, Thicknees used, material, Nominal height, Max. Operating temp., Sedemi s.c.c., Design specific gravity, Gal., Atm, Ninth, Tag, Diesel storage tank, Edition, Gaskets, Flexitallic cg, Heads, Bolts nuts, Cadmies, Pipe, Gr., Supports, Shell, Flages, materials, Manhole flange, Typ., Manhole, Manhole cap, Section, scale, Typ., Typ., Manhole cap, Manhole, Section, scale, Base plate, Stiffener, Stiffener, Stiffener, Stiffener, Top flage, Wear plate, Web, Typ., Typ., Typ., Typ., Typ., Typ., Typ., Typ., Stiffener, Stiffener, Front view, Saddles, scale, Section, scale, section, scale, section, scale, view, Sc., Esc., view, Sc., Esc., asparagus, Top view, Manhole, scale, Typ., Saddles, brand, Cant, description, long, Total weight, observations, Weight u., Cant, Total weight in the drawing, Manhole, brand, Cant, description, long, Total weight, observations, Weight u., Cant, Total weight in the drawing
Raw text data extracted from CAD file:
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
Xxx, Building construction, Notes:, This plan contains information owned by petroamazonas e.p. It is expressly forbidden to copy the use without written authorization of petroamazonas e.p., General notes, date, reviewed, General approval, Ing. draft, Ing. design, cartoonist, Engineering registration design, firm, M.c., to the., C.ch., number, Reference drawings, description, Rev., Revisions, date, drawing, revised, Approved, scale, size, Rev., drawing, description, client, draft, sheet, None, Emergency vent, R.f., Includes blind flange, Vent goose neck, R.f., Overflow, Cplg, Lsl lsh, Screwed bar, Outlet, R.f., Head, Drain, Return, R.f., Shell, Inlet, R.f., Head, Manhole, Qty, Service, Size nps, Location, Observe, Mark, Accessories list, Angle, Cplg, Shell, Head, R.f., Screwed bar, Top view, Manhole flange, scale, hydrostatic test, Corrosion allowable, Mm head tank body, Operating pressure, Atmospheric, design temperature, rated capacity, Gal., length, Operating temperature, diameter, code, Design pressure, Atmospheric, Wind speed, Product store, diesel, Earthquake, Seismic group no. Iv according to the nec, Inspection of welded joints, Spot x-ray, Design conditions, protection, Internal surface preparation, Sigma novaguard eps epoxy phenolic, Sigmaguard eps epoxy phenolic, Sigmacover mils, Sigmafast mils, External surface preparation, Sigmadur mils, Psig as required by, Ral, the UL, Tank weight accessories, Kg., Weight supports, Kg., Heads, Type, Appendix, Diameter Nominal, Nominal capacity, Design pressure, Edition, Serial no., Fabricated by, Service, Year built, Shell, Thicknees used, material, Nominal height, Max. Operating temp., Sedemi s.c.c., Design specific gravity, Gal., Atm, Ninth, Tag, Diesel storage tank, Edition, Gaskets, Flexitallic cg, Heads, Bolts of nuts, Cadmies, Pipe, Gr., Supports, Shell, Flages, materials, Manhole flange, Typ., Manhole, Manhole cap, Section, scale, Typ., Typ., Manhole cap, Manhole, Section, scale, Base plate, Stiffener, Stiffener, Stiffener, Stiffener, Top flage, Wear plate, Web, Typ., Typ., Typ., Typ., Typ., Typ., Typ., Typ., Stiffener, Stiffener, Front view, Saddles, scale, Section, scale, section, scale, section, scale, view, Sc., Esc., view, Sc., Esc., asparagus, Top view, Manhole, scale, Typ., Saddles, brand, Cant, description, long, Total weight, observations, Weight u., Cant, Total weight in the drawing, Manhole, brand, Cant, description, long, Total weight, observations, Weight u., Cant, Total weight in the drawing
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Block |
Category | Water Sewage & Electricity Infrastructure |
Additional Screenshots | |
File Type | dwg |
Materials | Other |
Measurement Units | |
Footprint Area | |
Building Features | Car Parking Lot |
Tags | autocad, block, cover, diesel, digester, DWG, fuel, gas, griffin, horizontal, kläranlage, pipeline, stand, support, tank, treatment plant |