Initial Education Center DWG Block for AutoCAD
INITIAL EDUCATION CENTER – PLANTS – structural development – SLAB LIGHTENED
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
path in plan, cut xx, overlay, foundation, wall, cut and and, splices of the reinforcement, of light of the slab or, beam on each side of, the column or support, will not be allowed, the joints l, will be located in the , central third, no more splices, armor in one, same section, rmax, slabs and beams, overlaps and joints, slabs, beams, columns, stirrups, columns, corrugated iron, standard hooks in rods box, in the box shown., longitudinally, in beams, the reinforcing steel used, will be housed in the concrete with standard hooks, which, and beams, should end in, the specified dimensions, and foundation slab, column, note :, detail of stirrups, db, length of joint, special care should be taken to the correct placement inside, of the formwork of all the indicated irons., and other elements that should be embedded in the concrete., these elements should be well insured and avoid that, move during the process of placement of the concrete, the formwork should be sufficiently impermeable as, to prevent loss of grout and mortar, the inside face of the formwork should be clean and free of particles, various., the minimum deadlines for removal of formwork and elements of , sustain, will be governed by the following times:, – beams and columns sides:, characteristics of the formwork, removal of formwork, formwork and formwork, technical specifications, – unit: king kong clay bricks, confinement column, beams structural, columns of confinement, – joints of iron, structural columns, footings, – compression masonry:, – solid brick kk clay:, – specific weight masonry:, false floor, sobrecimientos, joints on the supports being the length of, the percentages specified, increase the length of, notes, cm., in., d steel, upper m, lower m, – the quality of the steel The reinforcement shall not exceed what is specified for arn grade steel, – the splices shall be made only as required or permitted by the design plans, – the overlap splices of the reinforcement in areas of stress inversion, shall remain, – no splices shall be made overlaps or soldiers in the reinforcement within an area, beam on each side., technical specifications or as authorized by the inspector., – the sites may be of different types :, shall be treated as an element in flexocompresión., – beams that must be resist earthquake forces shall comply with what is indicated in this, overlapping splices of corrugated bars, – the minimum length of a splice overlapped in compression shall be the length of development within a required length of overlap type c splice shall be used. , required overlap type b splices should be used. if more than half of the ba- is joined, strictly necessary and if less than half of the bars are spliced within one length, – splices in areas of high stress should preferably be avoided, however, if they were, where is the length of the splice, and ld is the length of development in traction., – the minimum length of the overlap in the splices overlapped in traction will be in accordance with the re, package should not coincide within the same overlap length., – the bars spliced by means of overlaps are contact in elements subjected to bending, no, – the overlaps of bars forming packages must be based on the required overlap length, section for the design of the longitudinal steel., splices in the reinforcement, subject to comprehension, subject to traction, splices by overlap, detail of the location and length, overlapping splices for columns, morteo :, maximum, before starting the second, day clean and moisten, for better adherence, for the second day, for solid units., the alveoli, should not exceed the type IV brick, detail of low ceiling, window, lightened, beam, height see cuts in foundation plane, detail constructive, wall, column steel, see table of columns, striped joint, the beam or collar, or in the sobrecimiento., sufficient rugosity and, in addition they must be, clean of particles, stirrups colunmas, additional stirrups, concrete in columns, the concrete of colunmas, must reach until the foundation, before starting the second one, mortar, for a better adhesion, flooring, in the footings they should not be, affirmed, own, compacted., filled with material, detail of anchoring of column in shoe, coating, bending detail beams, beam, column, union beam-column, type, frame of stirrups, ø rd, typical detail of bending of stirrups, corridor, pedagogic classroom, tongue and groove floor, deposit, ss. hh., girl s, children, mooring column, mooring beam, main column, puno region, regional government, … honest and productive, orientation :, esc
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Block |
Category | Schools |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Masonry, Steel, Other |
Measurement Units | Metric |
Footprint Area | |
Building Features | |
Tags | autocad, block, center, College, development, DWG, education, initial, library, lightened, plants, school, slab, slab lightened, structural, university |