Public Drinking Water Project DWG Full Project for AutoCAD
Planned route of public drinking water
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
building, building, Min, detail, detail, Schematic type spindle column n.ch., denomination, crown, stem, Rubber seal, stop, head, Nozzle cover, prisoner, nozzle, Packing, base, Take chain, chain, body, Support plate, cap screw, Rador, Panker, Circlips, Sealing washer, Valve plate, Building, Recognition well, Minimum density of proctor, Minimum support capacity, Minimum density of proctor, Modified support capability, Up to one weight, Modified in sidewalk., Material maximum size, Minimum density of proctor, Material maximum size, Modified for the, Filler arrangement, Minimum density of proctor, maximum, modified., Of total soluble mineral salts., Of the c.b. In road, Bed support pipe, Compressed clean sand., Minimum, scale, Granular material size, Well-graded sand with, Degree of collapse, Middle sand stratum of, in the first, Color light coffee with some, Symbology, Recognition well, reference point, Chamber collector, Projected inspection, Existing inspection, Chamber collector, emissary, Reference level, Direction flow direction, Housing, drawing, F. M. C., flat, letter, COO, draft, reviewed by, engineering manager, date, Head of department of studies, approval, Projected by jose figueroa, west, south, north, East, date, Service installation, Water antofagasta, Sewerage of antofagasta, civil engineer, Construction engineer, Four apartment buildings, Var., Fat to the stem, Driver of the, sponge, Grease nipple, nozzle, Driver of the, Fat to the stem, Grease, Body tap, zipper, To the rod, Grease outlet, zipper, From the tap, Solid body, stem, Of pressure, Plastic washer, column, Camera cap, Talmet, Type roadway, pool, tap, Type roadway, Talmet pn, Potable water valve, Talmet, pool, Camera cap, Gravel pit, column, tap, detail, detail, plant, Lifting cut, Detail valve for faucet valve, N.p.t, Lifting cut, designer, Type profiles, cut, sidewalk, Projected, matrix, Projected, manifold, living place, green area, Resistant of the work requires clearance of, Difficulties that arise during the execution of the, Plans of engineering of specialties. The doubts, Cast concrete: grade according to nch of, Works must be carried out with simultaneous consultation of, Concrete beams slabs: grade according to nch, Steel for concrete:, Immediately consulted., Quality of materials, In case of doubt discrepancies between plans specifications, Can be modified in terrain if they do not alter the capacity, In cases structural solutions indicated in planes, Consult the designer., Technical regulations in force in Chile its regulations., In the execution of the present work, all the, General notes:, knot, Slab armor in sidewalk, stucco, cut, support for, Machon de, stirrup, cut, cut, Top mesh, Pool of, With grille, cut, pavement, Gravel, rack, Concrete of, Kg, Reinforced concrete, Machon de, support for, Cement tube, Pool of, Bottom mesh, top, Earth, chain, Earth, Tablet of, cut, pavement, Self-locking, meeting, Self-locking, meeting, Pass the wall, Detail valve chamber, Esc:, Sidewalk road without, To be used concrete wall of kg, Of thick instead of brick., Sidewalk with, Layout of hubicacion., Building, Taps, Valves, Avda. Season of the winds, Petronilla street, Jose santos ossa street, Street pedro aguirres bristle, Jose figueroa, Felipe muñoz, Plant of rear hubicacion of plumbing., Of waters of antofagasta without registry to manipulate the valve, Type with a ventilation hole with the logo, The potable water valves shall be, Oval body with flange connection type talmet pn, Metal type ductile cast iron, The pockets of the potable water valve chambers will be, If the spigot is projected sideways. The massif, The masses will be kg, Floor avoiding to be buried., natural terrain. Must be about the level of, Should be at the same level of this if projected in, In areas of great slope will avoid installing the faucet, The faucet shell will be installed one side of the, Of more extended concrete, same. In an extension of the concrete mass, The mouth of the spigot should face the surface, Column at points where water can undermine the massif, Bolt anchor bolts should be steel, Similary., of concrete., stainless., note, plant, Keep key, column, tap, elevation, Detail of locking faucet guard keys, unscaled, A.p.p., Housing, drawing, F. M. C., flat, letter, COO, draft, reviewed by, engineering manager, date, Head of department of studies, approval, Proye
Raw text data extracted from CAD file:
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
building, building, Min, detail, detail, N.ch., denomination, crown, stem, Rubber stamp, stop, head, Nozzle cover, prisoner, nozzle, Packing, base, Take chain, chain, body, Support plate, cap screw, Rador, Panker, Circlips, Sealing washer, Valve plate, Building, Recognition well, Minimum proctor density, Minimum support capacity, Minimum proctor density, Modified support capacity, Up to one weight, Modified in sidewalk., Material maximum size, Minimum proctor density, Material maximum size, Modified for the, Filler arrangement, Minimum proctor density, maximum, modified., Of total soluble mineral salts., Of the c.b. In road, Bed support pipe, Compressed clean sand., Minimal, scale, Granular material size, Well-graded sand with, Degree of collapse, Middle sand stratum of, in the first, Color light coffee with some, Symbology, Recognition well, reference point, Chamber collector, Projected inspection, Existing inspection, Chamber collector, emissary, Reference level level, Direction flow direction, Housing, drawing, F. M. C., flat, letter, COO, draft, reviewed by, engineering manager, date, Head of department of studies, approval, Projected by jose figueroa, west, south, north, East, date, Service installation, Water antofagasta, Sewerage of antofagasta, civil engineer, Construction engineer, Four apartment buildings, Var., Fat to the stem, Driver of the, sponge, Grease nipple, nozzle, Driver of the, Fat to the stem, Grease, Body tap, zipper, To the rod, Grease outlet, zipper, From the tap, Solid body, stem, Of pressure, Plastic washer, column, Camera cap, Talmet, Type roadway, pool, tap, Type roadway, Talmet pn, Potable water valve, Talmet, pool, Camera cap, Gravel pit, column, tap, detail, detail, plant, Lifting cut, Detail valve for tap valve, N.p.t, Lifting cut, designer, Type profiles, cut, sidewalk, Projected, matrix, Projected, manifold, living place, green area, Resistant of the work requires clearance of, Difficulties that arise during the execution of the, Plans of engineering of specialties. The doubts, Cast concrete: grade according to nch of, Works must be carried out with simultaneous consultation of, Concrete beams slabs: degree according to nch, Steel for concrete:, Immediately consulted., Quality of materials, In case of doubt discrepancies between plans specifications, Can be modified in terrain if they do not alter the capacity, In cases structural solutions indicated in planes, Consult the designer., Standards in force in Chile its regulations., In the execution of the present work, all the, General notes:, knot, Slab armor in sidewalk, stucco, cut, support for, Machon de, stirrup, cut, cut, Top mesh, Pool of, With grille, cut, pavement, Gravel, rack, Concrete of, Kg, Reinforced concrete, Machon de, support for, Cement tube, Pool of, Bottom mesh, top, Earth, chain, Earth, Tablet of, cut, pavement, Self-locking, meeting, Self-locking, meeting, Pass the wall, Detail valve chamber, Esc:, Sidewalk, To be used concrete wall of kg, Of thick instead of brick., Sidewalk with, Layout of hubicacion., Building, Faucets, Valves, Avda. Season of the winds, Petronilla street, Jose santos ossa street, Street pedro aguirres sow, Jose figueroa, Felipe muñoz, Plant of rear hubicacion of plumbing., Of antofagasta waters without registration to manipulate the valve, Type with a ventilation hole with the logo, The potable water valves shall be, Oval body with flange connection of type talmet pn, Ductile cast iron type, The pockets of the potable water valve chambers will be, If the spigot is projected sideways. The massif, The masses will be kg, Floor avoiding to be buried., natural terrain. Must be about the level of, Should be at the same level as this if projected in, In areas of great slope will avoid installing the faucet, The faucet guard will be installed one side of the, Of more extended concrete, same. In an extension of the concrete mass, The mouth of the spigot should face the surface, Column at points where water can undermine the massif, Bolt anchor bolts should be steel, Similary., of concrete., stainless., note, plant, Keep key, column, tap, elevation, Detail of faucet hold key, unscaled, A.p.p., Housing, drawing, F. M. C., flat, letter, COO, draft, reviewed by, engineering manager, date, Head of department of studies, approval, Proye
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Full Project |
Category | Water Sewage & Electricity Infrastructure |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Plastic, Steel, Other |
Measurement Units | |
Footprint Area | |
Building Features | Pool, Car Parking Lot |
Tags | autocad, distribution, drinking, DWG, fornecimento de água, full, kläranlage, l'approvisionnement en eau, planned, Project, PUBLIC, route, supply, treatment plant, wasserversorgung, water, water network |