Commercial Facilities DWG Block for AutoCAD

health facilities; electric; hidraulica of commercial premises of 6.50x12m; cistern and have parking spaces. the single line diagram and load table of the electrical installation is included

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Building sajara s.a. Of c.v., shop, shop, dependent, Up pipe, Mm., tank, Dim: m., total capacity:, bomb, ., V.c., measurer, you., Of the municipal take mm., Ll.n., Low pipe, Mm., Low pipe, Mm., Towards general drainage network, draft, proficient:, owner:, Maria de la luz navarrete gonzalez, Location:, date:, drawing:, key:, scale:, Dimension: meters, Ing. Victor martiniano ramirez martin, Ced. Prof. D.r.o. Emau, Specifications:, flat:, Hydraulic installation, Saúl javier resendiz ambrocio, Of September, Notes:, All diameters are in millimeters this plane will be used only for hydraulic installation, draft, Business premises, proficient:, owner:, Maria de la luz navarrete gonzalez, Location:, date:, drawing:, key:, scale:, Dimension: meters, Ing. Victor martiniano ramirez martin, Ced. Prof. D.r.o. Emau, Specifications:, Street hidalgo no. cabbage. Santa julia hgo, flat:, sanitary instalation, Saúl javier resendiz ambrocio, Of September, All the diameters are indicated in millimeters., This plan shall be used only in installations, All exterior pipes will be pvc sewer line, All pipes inner connections will be reinforced pvc, Elbow of p.v.c. Mm, Yee with reduction of p.v.c. Mm, Yee simples de p.v.c. Mm, Elbow of p.v.c. Mm, Wastewater discharge, Registration tap, ventilation, sanitary registration, Street hidalgo no. cabbage. Santa julia hgo, registry, registry, Brand similar, Business premises, low, pipeline, shop, Of energy, feeding, Light energy attack fza., shop, Towards general drainage network, draft, proficient:, owner:, Location:, date:, drawing:, key:, scale:, Dimension: meters, Symbology:, flat:, Hydraulic installation, Notes:, All the diameters are indicated in millimeters this plane will be used only for hydraulic installation the mark to use will be tuboplus similar, Cold water line per roof, Cold water line per floor wall, gate valve, Indicates pipe diameter in mm., Indicates universal spanner wrench, Indicates elbow diameter pipe, Indicates tee pipe diameter, Indicates high pressure float, draft, Business premises, proficient:, owner:, Location:, date:, drawing:, key:, scale:, Dimension: meters, Symbology:, flat:, sanitary instalation, All the diameters are indicated in millimeters., This plan will be used only in sanitary installations, All pipes inner connections will be reinforced pvc, Elbow of p.v.c. Mm, Yee with reduction of p.v.c. Mm, Yee simples de p.v.c. Mm, Elbow of p.v.c. Mm, Wastewater discharge, Crazy brats, Loved nerve, gentleman, owner, draft, Art garden, Convention Center, clinic, Fco. Guzman diaz, Crazy brats, Loved nerve, gentleman, owner, draft, Art garden, Convention Center, clinic, Fco. Guzman diaz, registry, registry, Brand similar, Business premises, Flattened, chamfer, Record detail, reinforced concrete, Perimeter shot of, Simple concrete, Pipe of, Template, concrete, Partition walls, Common annealed, Concrete cover, shop, shop, shop, registry, Up pipe, Mm., tank, Dim: m., total capacity:, bomb, ., V.c., measurer, you., Of the municipal take mm., Ll.n., Low pipe, Mm., shop, shop, shop, draft, proficient:, owner:, Location:, date:, drawing:, key:, scale:, Dimension: meters, Symbology:, flat:, Water heater installation, Notes:, All the diameters are indicated in millimeters this plane will be used only for hydraulic installation the mark to use will be tuboplus similar, Cold water line per roof, Cold water line per floor wall, gate valve, Indicates pipe diameter in mm., Indicates universal spanner wrench, Indicates elbow diameter pipe, Indicates tee pipe diameter, Indicates high pressure float, Crazy brats, Loved nerve, gentleman, owner, draft, Art garden, Convention Center, clinic, Fco. Guzman diaz, Business premises, Up pipe, Mm., tank, Dim: m., total capacity:, bomb, ., V.c., measurer, you., Of the municipal take mm., Ll.n., Low pipe, Mm., Low pipe, Mm., draft, proficient:, owner:, Location:, date:, drawing:, key:, scale:, Dimension: meters, Symbology:, flat:, Hydraulic installation, Crazy brats, Loved nerve, gentleman, owner, draft, Art garden, Convention Center, clinic, Fco. Guzman diaz, Business premises, shop, shop, shop, ramp, ramp, ramp, ramp, total, circuit, Load board, total, Inc. Of light fza., Before the placement of the conductors should be dried probe the pipes., Retacandolas of paper to avoid

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete
Measurement Units
Footprint Area
Building Features Car Parking Lot, Garden / Park
Tags , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT