ADVERTISEMENT

ADVERTISEMENT

Conventional Wather Treatment Plant DWG Block for AutoCAD

Plant Design of 6,3 L/s to supply a small town with water quality characteristics rave

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

Water treatment services, Viaduct miguel aleman no. Col mexico d.f., Tels .: fax .:, CD. Of the camp., Residual water treatment plant, Operating booth, it is about, description, Plan issue, Airports, services, Auxiliaries, Location:, Meters, date:, flat:, Quotas, Mca., work:, Capacity lps, Airport, scale:, August, Esc:, drawing:, Flat number:, Jlrc, by:, Jlrc, Vo.bo., Jlrc, S.a., date, Symbology, Columns, Trabes, Road axle, Measurements in levels in meters, General notes, Overlaps, dipstick, materials, Coatings, Are defined in the figure, As the lg lt lg lg lg, do not. Cm cm cm cm cm cm cm cm cm, Reinforcement anchors, For rods with more than cm. Concrete under them, For rods less than cm. Of concrete under them., Indicates its arming are not scale., Free minimum shall be the greater of the following two values: the greater, Reinforcing steel modulus of elasticity, In elements that will not be exposed to the coating, Concrete class with volumetric resistance in, Construction that are annexed the project plans., Compliance with the general, Schemes of the various structural elements in which the, The remaining reinforcement could overlap in another section that you, Should not overlap more than the reinforcement of a, Overlaps are allowed for any rod diameter with lengths, Minimum diameter of the vein figure, In elements cast against the minimum free coating will be, The straight anchor lengths for rebar are specified in, If not done all the rods finished in squared, The anchorage of stapes stirrups will be made with a fold, Respecting the radii indicated in the table of rods, Cm. If cm is not used. If template is used., Of the two values ​​indicated in the previous paragraph., Exposed elements in weathering coatings will be double, Anchor in the normal elements as shown in the figure, Followed by a straight section as indicated in the figure, Indicated in the rod table., Architectural plans in the work., Of reinforcement cm., Simple pressure modulus of elasticity f’c, All fixed level cloths should be checked with the, The table of rods., Esc., draft:, Aqueduct, Samurai, Corregimiento, Purification, dump, Flocculator, Settler, filtration, Shredder, Sedimented, Water, Parshall, Sludge zone, cut, Esc:, Esc:, Input chamber, cut, Esc:, Xxxx, laboratory, Comes bocatoma, Parshall, Flocculator, Cut c ‘, cut, Structural brick blocks in perforated, Wash water inlet comes from pump, filtered water, Chlorination point, observations:, Number of plans:, Ing. Carlos mosquera, drawing:, revised:, design:, date:, scale:, Contains:, draft:, Plant profile, Xxxxxxx, Jr, Repubila de colombia, Carmen tulia orchards, Purification plant, Samurai, August, Choco department, Municipality of atrato, Corregimiento, draft:, Aqueduct, Arenal, Corregimiento, Purification, observations:, Ing. Edinson nagles vergara, revised:, Contains:, profile, Mat., Carmen tulia orchards, adduction, Number of plans:, drawing:, date:, scale:, Jr, August, Indicated

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Steel, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , ,

ADVERTISEMENT

CAD Drawings

Leave a Reply

ADVERTISEMENT