Detached House DWG Plan for AutoCAD
Two-story house with external stairs designed for 4-story structure – Plan of structures – structures – health – and details
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
sony, screw cap, note :, – the main entrance doors to the house and the bedrooms will be of wood type, – the door for entering the laundry will be of wood type screw or to decide on work., – the doors of the closets they will be counterplate and sliding, – the windows will be aluminum, direct system and double glass., – the pasamamos of the stairs, railings of rests and rails of the planters, – the painting will be washable latex and color to choose on site., polished cement laundry, cedar and wood screw, unless otherwise indicated by the owner., – the entrance door to the multipurpose room will be curtain rolling, technical specifications :, -all measurements must be verified on site., -all the dimensions are indicated in meters., -the dimensions of the structure must be specified, by the structural project, which must be res-, -do not use this plane for purposes other than that referred, petar the free heights indicated here. , -he furnished is representative., -the measures are axes and cloths., access path, first floor, vinilico color, silico calcareo floor, polished cement floor, color vinyl floor, polished cement, parquet, floors, plastering, wood, sockets , tarrajeo rubbed, mix cement sand, plastering plaster, granite, ceramic, sky, satin, ovalin, glass, doors, windows, iron, board, melamine, wood, glass, aluminum, carpentry, key knob, key with handle, tempered glass, schlage with handle, locksmith, toilet, double glass, latex, oil, enamel, paint, washbasin, wastebasket, shower, soap dish, appliances, toilets, circular fluorescent, mercury lamp, fluorescent straight, urinal, luminaires, second plant, varnish, venetian tile, floor, finishes, environments, finish table, main entrance, porch, multipurpose room, living room, staircase, sh, kitchen-dining room, terrace, passageway, car-port, patio- laundry, hall, roof, laundry, a lto, box of bays-doors, width, type, observations, wood type cedar, wood screw, quantity, location, s.h. of service, p-e, rolling shutter, plywood, kitchen-com. diary and hall of roof, picture of bays-windows, alfeiz., observations, polarized glass-direct system, window high-direct system, high window-double glass, high-aluminum window, s. h., deposit, living room, dining room and hall, vc, flooring, compaction, filling, anchoring detail of, straight walls, correct transmission of loads, inclined walls, gure the non-existence of water on the corresponding, any over- Excavation or overflow should be -, substituted said volume with concrete cyclopean of -, previous to the castings should be left the respective passes for the drainage pipes and other ins-, prior to the castings of the foundation structures-, flooring teeth, talaciones., important:, confinement in walls, detail of abutments, db, length of joint, fence, column anchoring, and beam, typical details, column, splices in the reinforcement, specifications, construction process, concrete , reinforcement steel, masonry units, mortar, important note :, technical specifications, – unit: king kong clay bricks, confinement column, structural beams, confinement columns, – splice iron month, structural columns, footings, – masonry compression:, – solid brick kk clay :, – specific masonry weight:, false floor, surpluses, – the quality of the reinforcing steel shall not exceed what is specified for grade steel, – the joints should be made only as required or allow the design plans, – the overlapping splices of the reinforcement in areas of stress inversion, should remain, – overlapping or welded joints should not be made in the reinforcement within a zone, beam on each side., technical specifications or as authorized by the inspector., – the sites may be of different types :, shall be treated as an element in flexocompresión., – the beams that must resist earthquake forces must comply with what is indicated in this, overlapping splices of corrugated bars, – the minimum length of a splice overlapped in compression shall be the length of development in, within a required length d and overlap should use splice type c., required overlap type b splices should be used. if more than half of the ba- is joined, strictly necessary and if less than half of the bars are spliced within one length, – splices in areas of high stress should preferably be avoided, however, if they were, where is the length of the splice, and ld is the length of development in traction., – the minimum length of the overlap in the splices overlapped in traction will be in accordance with the re, package should not coincide within the same overlap length., – the bars spliced by means of overlaps
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Plan |
Category | House |
Additional Screenshots | |
File Type | dwg |
Materials | Aluminum, Concrete, Glass, Masonry, Plastic, Steel, Wood, Other |
Measurement Units | Imperial |
Footprint Area | |
Building Features | A/C, Deck / Patio |
Tags | apartamento, apartment, appartement, aufenthalt, autocad, casa, chalet, designed, detached, dwelling unit, DWG, external, haus, house, logement, maison, plan, residên, residence, stairs, story, structure, structures, unidade de moradia, villa, wohnung, wohnung einheit |