Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Electric Power Transformer DWG Block for AutoCAD

Electric Detalils transformer mounting

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

kind, M.s.n.m., C.p.s., O.a., Prolec similar, altitude, Connection, impedance, frequency, Phases, Kva., brand, Transformer board data, Volts, Tension in secondary, Volts, Primary tension, brand, Fuse cutout for amp., clamp, Bracket with clamp, Low voltage cable lime. Awg., Platform of faith galv. With clamp, Galv., Suspension insulator, Concrete pole, Transformer kva., Bare copper wire lime. Awg., Muff conduit, Weather action., Interrupting capacity amp., lime. Awg with ground rod mechanical connector, Ground system with bare copper wire, Self-valvular karst. outdoor., High voltage bus lime. Acsr, Pericos for live line connector, Molded fork with guard bolt double screw bolt, Condumex, Color color, Condumex, Color color, Iusa, Color color, Fabypsa, Gen. Elec., omega, Condumex, Selmec, P. Z. to., M. T. S., P. Z. to., M. T. S., P. Z. to., M. T. S., P. Z. to., Material specifications, Stirrup for live line connector, Semi-hard bare copper wire lime., Live line connector, Wire stirrup, Bypass type compression connector, Main driver acsr, M. T. S., P. Z. to., M. T. S., unity, quantity, Part., lime., Cu cable. Thw, Live line, Connector, Hard naked, Copper on, Wire of, Type l.t, bimetallic, Connector, Acsr cal., driver, Cm., View detail of, stirrup, Mm. Long., Type copperweld mm. from, Rod for earth connection, lime. Awg., Bare copper cable, Connection log, Electrode installation, brand, Stirrup connector, Ground system detail, Land registry, View detail of, Connection detail, Copper wire, Bare lime Awg, Cable lime., Weldable connection cadweld, Mol of cartridge ta, Material box, mold, cartridge, Metal connector mca. Burndy cat. Cadweld welding, Materials for reg. of Earth, Ground rod coperweld of mm. Long., Semi-hard bare copper wire lime. Awg condumex, description, Wall of, measurement, Apartment, box of, Connections, See standard of, building, Apartment, services, Apartment, Cant, The substation equipment must be installed installed to reduce, To the minimum the risks of accidents of the as well as the consumption, Of energy according to art., The substation must have on the side a general device, Overcurrent protection is adequate, Current of the service according to art. of the, The protection devices against both the side, Primary and secondary must be of interruptive capacity, Appropriate., The substation must have an adequate land system., This system consists of buried copperweld ground rods, Mts of depth interconnected in delta with welding cadweld, Connectors gar. That allows to obtain the minimum value of earth resistance., The transformer tank must be connected to the earth system., Notes, Notes:, Electrode installation, location, Note: the specified materials may be replaced for that they meet the requirements, Established by the general direction of norms., unity, Standard c.f.e., structure, Concrete pole, Fc protective rod, Mooring wire fc, short description, Similar fabypsa, Similar corcor, Condumex similar, P. Z. to., P. Z. to., quantity, unity, P. Z. to., clamp, pin, insulator, Iusa similar, cross-piece, brand, Material structure, Standard c.f.e., structure, Similar fabypsa, Similar corcor, Condumex similar, Iusa similar, Similar corcor, P. Z. to., P. Z. to., P. Z. to., unity, P. Z. to., quantity, brand, insulator, Fc protective rod, Mooring wire fc, clamp, Screw machine mm., license plate, tight, Concrete pole, short description, clamp, pin, cross-piece

Raw text data extracted from CAD file:

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

kind, M.s.n.m., C.p.s., O.a., Prolec similar, altitude, Connection, impedance, frequency, Phases, Kva., brand, Transformer board data, Volts, Tension in secondary, Volts, Primary tension, brand, Fuse cutout for amp., clamp, Bracket, Low voltage cable lime. Awg., Platform of faith galv. With clamp, Galv., Suspension insulator, Concrete pole, Kva transformer., Bare copper wire lime. Awg., Muff conduit, Weather action., Interrupting capacity amp., lime. Awg with ground rod mechanical connector, Ground system with bare copper wire, Self-valvular tipping kv. outdoor., High voltage bus lime. Acsr, Pericos for live line connector, Molded fork with guard bolt double threaded bolt, Condumex, Color color, Condumex, Color color, Iusa, Color color, Fabypsa, Gen. Elec., omega, Condumex, Selmec, P. Z. to., M. T. S., P. Z. to., M. T. S., P. Z. to., M. T. S., P. Z. to., Material specifications, Stirrup for live line connector, Bare copper cable semi-hard lime., Live line connector, Wire stirrup, Bypass type compression connector, Main driver acsr, M. T. S., P. Z. to., M. T. S., unity, quantity, Part., lime., Cu cable. Thw, Live line, Connector, Hard naked, Copper on, Wire of, Type l.t, bimetallic, Connector, Acsr cal., driver, Cm., See detail of, stirrup, Mm. Long., Type copperweld mm. from, Rod for earth connection, lime. Awg., Bare copper cable, Connection log, Electrode installation, brand, Stirrup connector, Ground system detail, Land registry, See detail of, Connection detail, Copper wire, Bare lime Awg, Cable lime., Weldable connection cadweld, Mol of cartridge ta, Material box, mold, cartridge, Metal connector mca. Burndy cat. Cadweld welding, Materials for reg. of Earth, Ground rod coperweld of mm. Long., Bare copper cable semi-hard lime. Awg condumex, description, Wall of, measurement, Apartment, box of, Connections, See standard of, building, Apartment, services, Apartment, Cant, The substation equipment must be installed maintained to reduce, Minimum risk of accidents as well as consumption, Of energy according to art., The substation must have on the side a general device, Overcurrent protection is adequate, Current of the service according to art. of the, The protection devices against both the side, Primary and secondary must be of interrupting capacity, Appropriate., The substation must have an adequate land system., This system consists of buried copperweld ground rods, Mts of depth interconnected in delta with welding cadweld, Connectors That allows to obtain the minimum value of earth resistance., The transformer tank must be connected to the earth system., Notes, Notes:, Electrode installation, location, Note: the specified materials may be substituted for those that meet the requirements, Established by the general direction of norms., unity, Standard c.f.e., structure, Concrete pole, Fc protective rod, Wire fc mooring, short description, Similar fabypsa, Similar corcor, Condumex similar, P. Z. to., P. Z. to., quantity, unity, P. Z. to., clamp, pin, insulator, Iusa similar, cross-piece, brand, Material structure, Standard c.f.e., structure, Similar fabypsa, Similar corcor, Condumex similar, Iusa similar, Similar corcor, P. Z. to., P. Z. to., P. Z. to., unity, P. Z. to., quantity, brand, insulator, Fc protective rod, Wire fc mooring, clamp, Screw machine mm., license plate, tight, Concrete pole, short description, clamp, pin, cross-piece

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Other
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

CAD Drawings

Leave a Reply