Electric Projects Medium Voltage DWG Full Project for AutoCAD
Electric project in medium voltage – Private School
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
relief valve, Disconnector, Elbow support, Shunt changer, Data plate, Sampling valve, Tightening torque plate, Bayonet fuse, Well terminal, Fluid filling coupling, Land bar, Sword type terminals, Sign plate, compartment, Low voltage, High tension, compartment, Pedestal transformer, interior view, stream, sidewalk, Installed load, Kw motor pump, Boiler engine, Hydro engine, Kw contacts, Lighting kwhab., Kw climate, Office climate, Refrigerator cooler kw, motor, neon sign, microwave, Incandescent lighting, Incandescent lighting, Hawthorn, sidewalk, fa., Fb, Motor pump, Cafeteria, office, living room, living room, living room, living room, Lighting workshops, Lighting lounges, exterior lighting, Contacts, Electric door, total, Substation type kva single-phase pedestal radial connection, location, Responsible expert, Electrical distribution network, scale:, flat:, date:, Plan no., definitive, front view, side view, lime. Awg, Cu cable. naked, N.t.n., switch, Thermomagnetic, Tube for transition color black, Recording in medium voltage of passage, Base for meter terminals amps, piece, piece, amounts of work, Underground electrification substation, Power cable ground adapter lime. Awg, Connector type elbow operation with similar occ charge, Single-phase transformer pedestal type radial operation, Kva capacity with the transformation relation, Built to the norm, Concrete base for kva pedestal type transformer, Power cable gauge awg insulation xlp specification, Copper cable insulation thw gauge awg, Aluminum connector for live line, Kv power thermocontractable terminal, Outside service for aluminum lime cable., Wood yoke stand separator cable, Octagonal concrete pole esp cfe, Lightning arresters, metal oxide for kv esp. Cfe, Weldable connector for copperweld rod, Connector bracket for cable cu. Cal awg, Copperweld rod, Pin insulation type ph, Transition energy, Awg gauge copper wire, Clamp ul, Fuse links Ampere rating, Mm underground pvc pipe, C.f.e. Similar brand condumex, The raychem brand similar, piece, piece, piece, piece, piece, piece, piece, piece, meter, piece, piece, P.g, piece, Cadweld welding, Materials to install, For n.t.i.e., Mm reduction mm, With amp poles., Galvanized mm pipe, Thermomagnetic switch with cabinet nema, The maximum distance between the base, Mm copperweld copper rod, Switch will be cms., In diameter by long, For measurement, Conduit pipe thick wall of mm, The thread of the tube must fit, Socket outlet, As required between the base, Coupling with elbow degrees mm, The base correctly, Of the transformer, your B. Wired to the inside, side of the, sidewalk, Meter c.f.e, The latter through, Prior to the installation of the power cable, a registry cleaning, For the installation of the power cable, the maximum pulling tension must be analyzed., In average tension norm, The earth resistance should not be higher ohms., With a length equal to the log perimeter., For the installation of the power cable must be invariably used as a screwdriver., Once the construction of the line has been completed, an insulation test, Please refer to the c.f.e. For construction of underground lines, For more detail of construction of the well of the visit the register in average tension, In all records of m.t. Reserve drivers should be left, The neutral tank of the, The groundbreeder attachments should be, The operating elbows with load when they are installed in a position that, As well as the b.t. The inside of the o.c.c., The wells should be lubricated with silicon grease., The fully operated operation elbows must be installed with a torque wrench, Cables etc., Facilitate its operation, Awg gauge thw cable, Notes:, Maximum radius of curvature, To power cable, Sock for pulled, Cable cu. lime. Awg, Low voltage recording, Earth system, Cu cable. Naked caliber awg, For physical soil, Transformer base, Ground rod of m., Land delta, Cm. Of separation of each edge, Mean, Kva, Kva, Symbology, Base register for transformer, Medium voltage underground line, measurement, Earth system, Single-phase transformer type kva pedestal, Elbow type connector for kv lime., duct bank, Kva, Single-phase transformer type kva pedestal, Existing record, Champaign, Cap ring, me., All the armed, Open carcamo, see note, Polished finish c
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Full Project |
Category | Mechanical, Electrical & Plumbing (MEP) |
Additional Screenshots | |
File Type | dwg |
Materials | Aluminum, Concrete, Wood |
Measurement Units | |
Footprint Area | |
Building Features | Car Parking Lot |
Tags | autocad, DWG, einrichtungen, electric, facilities, full, gas, gesundheit, l'approvisionnement en eau, la sant, le gaz, machine room, maquinas, maschinenrauminstallations, medium, private, Project, projects, provision, school, voltage, wasser bestimmung, water |