Electric Substation 30 Kva DWG Full Project for AutoCAD

THIS PROJECT IS DONE ADJUSTED NOM – 001 – SEAT – 1999 OFFICERS AND GENERAL GUIDELINES force and applicable; (3Ø, 13, 200 – 220Y/127 VOLT) The project is for a treatment plant.

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

measurements in meters., the construction of electrical equipment used in this substation should, the post will be drilled the indicated height in the plane to carry by, the underground conduit should be drowned in concrete cm., all metal parts such as, the ground resistance of the system should not be greater than ohms. in case, depth, earthy, metal parts that normally do not have to be, higher this value should be reduced by increasing the number of, energize that they are exposed they must connect rigidly, adjust the general official guidelines, rods in parallel., its inside the ground wire up to the copperweld rod, measurement, wall detail, localization map, nm., log for rod inspection, bare copper cable lime. do not., bare copper cable, lime. do not. awg, detail of the ground network for, landing of low voltage equipment, volts, air substation type on a pole, fus. amps., lime. do not. public road, fus. of amps., tube of fox thick wall of mm. for earth downs with lock nut, heat shrink sleeves to insulate the low voltage terminals of the transformer, do not., octagonal reinforced concrete pole, measuring equipment c.f.e. base of measurement a., constructed with up-to-date standards of, to ground devices in neutral medium voltage, with a flat one a.c., eye line shot, crosshead of fo.go., fork with thimble., suspension insulator, platform of fo.go. kind, reinforced jaladera suitable for weight., bare copper wire lime. do not. awg., parallel staple for retention, concrete anchor anchor, preformed finish for lime. do not., display, of air distribution., conduit tube thick wall of mm. towards i.t.m., against monitor for flexible metal tube mm. or., conduit tube fo.go. thick wall of mm. or., kv medium voltage bus acsr cable lime. do not. awg, amp thermomagnetic switch with nema metal cabinet, copper caliber with perico type connectors for live line a.t., material specifications, autovalvular to operate in kv., ground system with bare copper wire lime. do not. rods, in the transformer., transformer three-phase kva hz pole type., low voltage cables lime. do not. type volts., throat to accommodate nozzles in low voltage transformers avoid, flexible metal tube insulated with plastic lining of mm. or., insulator for retained porcelain type glazed coffee., anchor bolt for retention ipa. from fo.go. mm. mm. long., double threaded bolt with flat pressure washers., copper caliper lime. do not. with type connectors for acsr wire, electric base block registration includes concrete cover, high strength galvanized steel cable for retaining mm. of ø., galvanized steel guard for retaining mm., electric substation on pole, copperweld of mm. mm. long. with weldable connectors, wall for measuring niche built based on updated standards of c.f.e., niche to contain updated measurement equipment

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Full Project
Category
Additional Screenshots
File Type dwg
Materials Concrete, Plastic, Steel
Measurement Units
Footprint Area
Building Features Car Parking Lot
Tags , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply