Help on GoFundMe

ADVERTISEMENT

ADVERTISEMENT

Facilities Against Fire / System / Fire DWG Block for AutoCAD

fire facilities

Drawing labels, details, and other text information extracted from the CAD file:

hr conference, room, rep, rep, waiting, area, material, planner, material, planner, hse site, manager, atm, library, food, delivery, ramp, pipe chase, director, finance, dirctor, visitor’s, office, telephone, closet, computer, storage, work center, visitors, office, engineer, six, sigma, engineer, mail room, fax, printers, office, storage, closet, main conference, room, btm, microwave, bullpen area, for business team, materials, manager, accounting, supervisor, secretary, supervisor, examination, room, cabinets sink, lan, hub, events, center, kitchen, cafeteria:capacity, pipe chase, new employee, training, room, security, nurse’s, office, engineer, storage, closet, mens, janitor’s, supplies, masonry, block wainscot, janitor’s, closet, finance, clerk, womens, patio, plant, manager, plant manager, conference room, slop, sink, covered, docks, general refuse, cardboard, storage, receiving, inspection, concrete pad with, slanted sheet metal roof, shipping, office, remote maintenance area, ht., concrete floor, sheet metal construction, amp, disconnects required, recepticles required, lighting required, runway apron, iron bumpers, see detail, apron, soccer feild and, basketball court, cyclone fence with locked, surrounded by, coarse gravel, metal scrap, maintenance area, with crib on mezzenine, ramp down, maintenance dock, concrete pad for future, transformer, receiving, office, note: three concrete pads for propane, tanks to be supplied by propane supplier., water hydrant and lighting required., fence and gate required., gravel base inside fence except where, pads are located., retaining, wall, sliding, door, propane, fork lift, maintenance area, fork lift, charging area, main, substation, concrete pad with, slanted sheet metal roof, future, switch, gear, switch, gear, walk, collection trench, door, compressors, gallon, water tank, pump, house, containment, curb, cement, block wall, cement, block wall, containment, curb, note: exhaust ventillation with, air units required in, chemical stores room., note: all pits and trenches require stainless, steel liners for containment. floors must be, continuous with no joints allowed., note: electrical switches, and lights osha approved drum, explosion roof smoke and fire steel, roof sheetrock, in fire rated door with explosion bolts required, in flammable storage room., slope, epoxy seal, floor, epoxy seal, floor, trench, flammable, stores, hazardous, stores, containment, pit, sump, high, big door, hose, bib, hose, bib, hose, bib, tiki hut, bradley, sink, bradley, sink, bradley, sink, bradley, sink, bradley, sink, bradley, sink, npt, npt, pend., npt, pend., npt, injertado, tapon capa, cople, valvula de, compuerta, drean auxiliar, tuberia principal, abrazadera tipo pera, detalle de soporte, orificio:, temperatura:, factor k:, rosca:, rociador tipo: upright, modelo:, acabado: bronce, rociador, con candado, varilla roscada, brida ciega, simbologia simbology, longitud de tuberia, diametro de tuberia, gabinete, tapon capa, rociador upright modelo, altura de tuberia, riser

Raw text data extracted from CAD file:

Language English
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel
Measurement Units
Footprint Area
Building Features Deck / Patio, Car Parking Lot
Tags , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT