Fire Sprinkler Pump House DWG Block for AutoCAD
Automatic Sprinkler system Pump House layout
Drawing labels, details, and other text information extracted from the CAD file:
plan view, elevation a-a, elevation b-b, pump house plan view, section c-c, suction line detail, note:-, this drawing to be read in, conjunction with drawing, auto start detail, not to scale, jockey pump detail, wall bracket detail, pipe stand detail, pipe support detail, test pipe detail, orifice plate detail, to be worked out, ‘_zoom, f.f.l, diesel pump plinth, inside tank, pipe stand, stop valve, inhibitor, pump plinth detail, inside pump, room, bitumen, base, pressure gauge, to supply, sprinkler valves, eccentric, reducer, concentric, gauge, compound, double louver door, window, extraction fan, diesel tank, jockey pump, auto start, jockey, diesel, db by others, panel, above window, site plan, richard carte road, north, building, existing, siding reserve, ex. sewer, orifice plate, glycerine filled, pressure gauges, to tank, external catladder, manhole, infill valve, level indicator, window to detail, double, louver, door, full, empty, sprinkler, water tank, by others, primary diesel pump plinth, secondary diesel pump plinth, delivery to sprinkler, control valve station, by others flanges, tank infill by others, flanges to be sabs, minimum height required, pump plinth, power requirements for, sprinkler diesel pump and sprinkler jockey pump, power supplies, a distribution board to be installed in the pump room by the electrical contractor as, positioned on our detailed pump house layout., the d.b. to have the following breaker outlets as shown on the attached schematic, power layout., extracted from sprinkler rules, the power supplies, the power supplies for the pump room shall be, derived direct from :, room l.v. switchboard., the power supply shall be protected by means, of suitably rated switch-fuse unit or circuit, breaker on the main switchboard. the protective, power supply – not to be switched off in event of, all power supplies are required complete included inspection and approval, main isolator rated at, power point plug, power for artificial lighting, lights to be installed and wired by, electrical contractor, power for pump house heater, earth leakage, mains supply, main h.v., switchboard, transformer, main l.v., note work by:, belfa, main supply, for building, pump house l.v. switchboard, earth bar, neutral bar, isolator, annunciator, controller, feed to, plugs, lights, pumproom, heater if, required, batteries, alarms, engine, extractor, note:, all incoming cable to be, bottom entry only., by belfa, by electrical contractor, to waste, range pipe, for distribution mains, wall, galvanised u-bolt, strainer, union, suction, non-return, valve, delivery, u-bolt, main, angle iron, riser, channel, toothless anchor, pressure switch, non return valve, with cap, diaphragm valve, inlet, pump set, primary diesel, waste, back up, diesel pump set, secondary diesel, exhaust, drain, flashing to specialist, flexible couplings, concrete base, n.g.l, deep, pumps plinth detail
Raw text data extracted from CAD file:
Language | English |
Drawing Type | Block |
Category | Industrial |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Other |
Measurement Units | Metric |
Footprint Area | |
Building Features | |
Tags | autocad, automatic, block, bomba, bomba de água, DWG, fire, house, layout, pipe, pompe, pompe à eau, pump, pumpe, rohr, sprinkler, system, tubulação, tuyaux, wasserpumpe, water pump |