ADVERTISEMENT

ADVERTISEMENT

Foundation And Structures DWG Block for AutoCAD

Planes of structures and foundation

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

constructive detail, of wall, column steel, see table of columns, striped joint in, the floor beam or collar, or in the sobrecimiento., sufficient roughness and, in addition they must be, clean of particles, stirrups colunmas, additional stirrups, concrete columns, the concrete colunmas, must reach the foundation, morteo :, maximum, living room, shoe detail, foundation, additional, bathroom, garden, own material, filled with, see distribution of stirrups box of columns, kitchen, patio, before starting the second, day clean and moisten, mortar, for a better grip, for the second day, for solid units., note, c.- for lightened and flat beams, steel, specified , increase the length of splice, indicated or with the percentages, b.- in case of not joining in the zones, in the same section, internal splices on the supports, f’c, upper, lower, bar, length of development , bottom bar, no scale, top bar, beam, corrugated bars to traction, development lengths for, upper bars, values, internal reinforcement, h any, length, of the hook, development length in cm., lower bars, technical specifications, beams, footings, wall – column, bracing detail, column table, detail, type, abutments, special care should be taken to the correct placement inside, the formwork of all the indicated irons., and other elements that should be embedded in the concrete. , these elements should be well insured and avoid so, move during the process of placement of the concrete, the formwork should be sufficiently impermeable as, to prevent loss of grout and mortar, the inside of the formwork should be clean and free of particles, diverse., the minimum terms of removal of the formwork and elements of, sustain, will be governed by the following times:, – co stados of beams and columns:, characteristics of the formwork, removal of the formwork, columns of confinement, foundations, flooring for footings, concrete footings, concrete columns, sobrecimientos, false floor, concrete beams, masonry mortar, corrugated steel, standards, coatings, formwork and stripping, before emptying the concrete, clean well the teeth, avoiding the formation of burrs, and crabs., In turn use an appropriate technique of vibration or chuteo, avoiding breakage as much as possible. the teeth., use concrete with stones of, in your view, use an adequate vibration technique, or chuteo, avoiding as much as possible, the breakage of the teeth., typical detail of lightened, ø according to plant and type of lightened, empty of, empty of stairs, detail of steel anchor, of slab in beam, note: it will avoid making overlaps in areas of, minimum diameter of bending in longitudinal bar, nominal size of the aggregate in columns, plates, beams, slab, is lime and footing, flooring, minimum diameter of bending in stirrups, coating in slab and staircase, coating in beams and columns, coating in footings, masonry mortar, resistance to compression of the masonry, resistance to compression of the masonry unit, continuous overburden, reinforced foundation, steel yield strength, concrete compression strength, joists, recommended overlap zones, stairway foundation width, ladder, start

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Masonry, Steel, Other
Measurement Units Metric
Footprint Area
Building Features Garden / Park, Deck / Patio
Tags , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Startland Construction

Leave a Reply

ADVERTISEMENT