ADVERTISEMENT

ADVERTISEMENT

Mechanical Facilities Service Station DWG Block for AutoCAD

Mechanical Installations Service Station

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

entrance, exit, sub-station, area to be demolished, project :, plane :, mechanical installations – details, mechanical installations, location :, lamina :, scale :, date :, corner av. Ricardo Palm, district: Trujillo, department: Liberty, and Av. america south, tank of glp – details, scheme isometric installations of glp, av. south america, av. ricardo palm, market, tank glp, fourth, of machines, washing area, sh. muj., public, sh. hom., personnel, sidewalk, modification and expansion, yard maneuvers, air and water, underground point, transfer, deposit, painted strip color, totem, legend, liquid fuel vent pipe, symbol, description, recovery pipe liquid fuel vapors, discharge of glp, temperature thermometer, volume indicator, liquid level valve with two manometers, legend tank of glp, excess valve, flow, excess, valve, washing and oiling, housing, trade, counting, projection canopy, garden, projection of liquid fuel tanks, current status, kerosene, vapors, recovery valve, recovery pipe, filling pipes, discharge, existing fuel tanks, total, capacity, compartim., product, petrolmecanica glp, electro pump, multi-stage pump, grounding, box on floor with, hook connection, to tank, connection of sacrificial anodes, welding cadwell for, dg, fuel tanks , tanks, existing, new, tank, LPG, tank No., metal clamps, sand, asphalt pavement, or concrete slab, level of yard maneuvers, concrete, slab, for pipes, metal base, ventilation pipes, upper end of, valve and vacuum, necessary for the realization of the work. the number of accessories indicated, when it is not possible, the electrical lines must pass as a minimum, pedestal plant for the pvc tube, in the plane is referential, perforated with transversal cuts, with thin plastic, tanks., for leak detection, observation well, equipment, location of fuel exits or connections, electric dams before proceeding to dig the ditches of pipes, hands of anticorrosive paint and final color finish according to the national with galvanized iron seam of the heavy type, the access, the flow to the tank, once the pump has stopped operating, from the tanks to the dispensers, so that it is guaranteed, of ventilation, pedestal of pipes, pipe inside, rivers will be of the same material., in the dispensers., necessary steps in case of not being adequate., and protected with jute sheets with tar., norms., of the finished floor level., specification it is general:, flon and packing formers., for the lower part as for the upper part., gravel, notes :, grouting, threaded adapter, cross-section, cuts, for the well, padlock, manhole, exit level, submersible pump, recovery, ventilation, out, ventilation, see detail, observation, well, see detail of, recovery of, vapors, compacted, affirmed, measurement box, filling, measurement, box, observation well, detection of leaks, tank case, liquid fuel, underground tank plant, legend of the dispenser, denomination, nipple, technical specifications of the LPG dispenser, the dispenser will have the following technical specifications :, electronic dispenser of double hose brand high cabin, double special hose for simultaneous dispatch by both parties, digital display with volume indication in liters, unit and total price, in nuevos soles, electronic computer, vapor eliminator, differential pressure valve, automatic density and temperature compensator, hoses with pull-away valve, pistols type brevetti with automatic disconnection, in the lower part it will have excess flow valve rego or, ficher, carbon steel control valves apollo , flexible connectors between the pipe and the dispenser, in the return pipe will have a socket with control valve, for calibration of the meter, electronic button, emergency stop button, the calibration of the dispenser will be certified by indecopi., the hoses that will be used in the LPG dispenser will comply with the following specifications: be of plastic material resistant to the LPG product, be resistant to the action of LPG with a minimum rupture pressure, have a quick closing valve on its free end ., to be protected from excessive hydrostatic pressures by installing valves at their ends safety, whose psi., have at one end a weak section or a separable link, in case of suffering an abnormal traction, have at one end, with an automatic device that prevents, the emptying of the glp outdoors, in the event of rupture of the

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Concrete, Plastic, Steel, Wood, Other
Measurement Units Metric
Footprint Area
Building Features Garden / Park, Deck / Patio
Tags , , , , , , , , ,

ADVERTISEMENT

CAD Projects

Leave a Reply

ADVERTISEMENT