ADVERTISEMENT

ADVERTISEMENT

Multifamily 5 Story DWG Block for AutoCAD

Construction of multi-family housing; It has 5 floors.

Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):

npt., ebv, design:, ebv., plane n, date :, esc., autocad, drawing, project :, project – multifamily housing, owner :, mr. juan, plano:, architecture – distribution, acad, indicated, structures – foundations, structures – structures, structures – lightened slabs, garden, room, ceramic floor, slab floor, entrance, distribution first floor, second floor distribution, alley, door lift, garage, shop or desk, kitchen – dining room, patio, sshh, venetian tile, eaves, projection, bedroom, ceramic floor, level, beam detail collar, beam collar, vc-mp, larger dimension of the column, confinement area :, – greater value of the following condition, – separation of abutments in confinement area, outside the confinement area :, confined area, non-confined zone, notes: no splices are allowed in the confined areas. , ligatures in the node according to calculation, smáx, edge beam, zapata corrida – tipica, variable, del, hook, length, ø of column ca, ø of joist goes, detail of reinforcing wire in bearing walls, notes: brick for walls , r min., typical detail d e enclosed abutments, connecting detail beams – columns, variable, column, sobrecimiento, girder, beam girder, columneta and confinement beam typical first floor, door, columneta and confinement beam typical second floor, stirrups, emp., long., slabs and beams, overlaps and splices, in columns, traction, compression, columns, beams, overlaps, standard hooks, element, —, rmín., ls, ss, ls: splice length, db, type, f’c , zapata corrida, characteristics of the structure: structural system, local conditions:, building category, structural system: dual, maximum inter-floor distortion, dynamic analysis:, required resistance:, confinement columns, – iron joints, columns structural, beams, floors, houses, footings, – unit: king kong clay bricks, confinement column, – stratum to be cemented: clayey silt cl, – masonry compression:, – brick ma ck kk clay type iv :, – specific masonry weight:, false floor, overburden, technical specifications, corridors and stairs, – soil aggressiveness: negligible, – cement in foundations: type i, – estimated settlement: see soil study

Raw text data extracted from CAD file:

Language Spanish
Drawing Type Block
Category
Additional Screenshots
File Type dwg
Materials Masonry, Other
Measurement Units Imperial
Footprint Area
Building Features Garden / Park, Deck / Patio, Garage
Tags , , , , , , , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Startland Construction

Leave a Reply

ADVERTISEMENT