Security Module 2D DWG Full Project for AutoCAD
It is a project of a security module for the municipality of Cochoapa el Grande; the project is to plant; courts; facades; structural; electrical installation; hydro – health; this DWG format; the entire document is 2D
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
variable, breakfast, bathroom, kitchenette, bedroom, parking, up, parapet, low, ground floor, first floor, main facade, entrance, exit, cut and – and ‘, x – x’ court, left side facade, side facade der., name of the map:, address of public works and, urban development, general data, graphic scale:, sketch of, location:, key:, date:, orientation:, scale:, cochoapa the big, general data, module of security, project:, municipality:, architectural, foundation plant, concrete ruler chain, red partition wall, annealed red partition wall, hand-compacted with pizon, reinforced concrete counter-barrier with, reinforced concrete footing with, continuous castle, castle is born, castle tops, armed ramp, steel for temperature, forged step, concrete, footprint, steel by bending, cant, ladder, the filling that is made under firm, all the walls will be ique red recoc., tencia, the mortar in the joints, will cover completely the faces, horizontal and vertical of the pieces., the thickness of the joints will be such as to allow a uniform layer, specifications, of the laboratory., existing in the region. , the dalas and the castles will have as di-, the form should be completely clean, leveled and lubricated before placing the assembly., in the case of the slab, it should be clean, lubricated and lead, minimum dimension: the thickness of the wall, and the concrete will have a foundation, in bars and slab concrete will be used with a, the appropriate proportion depending on the aggregates, it is advisable to consult a laboratory to indicate, before casting trabes and castles. , overlap times, at a distance of two times the cant of the beam, measured from the face of the support, will be placed in the middle of the indicated spacing, the first, alternately, rod in the low bed of the slab, and the other, senses, in case of a discontinuous edge will be made a fold or, locate it in the upper bed of the slab., in the props of the perimeter slab one will pass, the filling must be the optimum , according to recommendations, av., with the anchorage length, except those that bend to re-force the beams whose length will be according to the clearance of the-, type, variable registers, descending of sewage, ventilated pipe, joined with glue pvc and lubricated with, with copper tube type l with a diameter of, painted in yellow and joined with, sand., electrical mechanism., half-round., flattened and polished internally, bottom, thiner, diameters., tube of reinforced sanitary pvc of several, for house, lowering of gray water, lowering of sewage, lowering of rainwater, low cold water, cold water, pvc pipe, septum register, cold water pipe, pipe gas, ventilation detail, intermediate chain, enclosure chain, tr abe nervada, b.a.g., b.a.n., b.a.p., b.a.f., s.a.f., to the collector, general, roof plant, s.t.v., recip. portable, cal. a.l., reg. bp, laundry, shower, wc, washbasin, sink, water tank, jug, air, strainer, comes from the network, municipal, to the collector, general, isometric of, facilities, polarized monophasic contact landed, exit center, flying buttress, safety switch, load center, meter, grounded rod, indicates number of circuit, connection, line piped per floor, line piped by walls and slab, up cables, lower cables, symbology:, neutral, grounding, technical specifications, do in condulets and registration boxes, – the height of the receptacles must be of, – the polarity of the receptacles must be respected, as indicated :, – the splices and derivations are only due, load and electrical boards of zone sera, – the height of the center or of the centers, in this project are manufactured and approved, – all the equipment and materials used in, be certified marks., – all the materials and equipment used in this, – the electric conductors used two are of copper, with, to provide the certification of the same, – the pipe of diameter not indicated and the minimum diameter, registered and certified by ance or another organism, this project are manufactured and approved according to, – the suppliers of equipment and materials must, the conduit must be firmly fixed as minimum, meter of all output, junction box, cabinets, approved certifier, box of devices and box of passage, – the location of outputs and equipment as well as the trajectory of The pipework is representative, it will coordinate with the work direction for any change, – all metal parts of the cabinets must be landed on the physical ground system, – the neutral conductors must be properly identified with the circuit number, to which it corresponds, – you should use a color code for the, easy ide
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Full Project |
Category | Police, Fire & Ambulance |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Steel, Other |
Measurement Units | Metric |
Footprint Area | |
Building Features | Garden / Park, Parking |
Tags | 2d, autocad, central police, DWG, el, feuerwehr hauptquartier, fire department headquarters, full, gefängnis, grande, module, municipality, plant, police, police station, polizei, poste d, prison, Project, security, substation, umspannwerke, zentrale polizei |