ADVERTISEMENT

ADVERTISEMENT

Standpipe Riser And Valves DWG Detail for AutoCAD

Detail Riser, valves and other

Drawing labels, details, and other text information extracted from the CAD file:

diametro de riser, area, diametro, almacen, almacen de, almacen de, almacen p.o.p., circuito de mangueras, cuarto de bombas, all fittings and nipples are galvanized, qty., valvula check, drain, to drip, suitable, or other, funnel, check, valve, alarm, tube connector, pressure relief, psi, description, psi, pressure relief, globe valve, long, no., ch: common hardware., supply, pressure, gauge, pressure, pressure, valve, control, relief, gauge, system, notes:, description, tee, nipple, no., qty., escenario para, almacenes, circuito, escenario, circuito, mangueras, escenario, almacen p.o.p., riser, circuito, soporte, vias, switch flujo, trim gauges, riser check, valvula ranurada, dren, cople flex., valvula, mariposa, mangueras, principal, soporte, vias, viene de red, valvula mariposa, riser, circuito, soporte, vias, switch flujo, trim gauges, riser check, valvula ranurada, dren, cople flex., valvula, mariposa, s.c.i., tub. cierre, soporte, vias, viene de red, riser, circuito, soporte, vias, switch flujo, trim gauges, riser check, valvula ranurada, dren, cople flex., valvula, mariposa, s.c.i., principal, soporte, vias, viene de red, cople flex., linea secundaria remota., valvula de prueba en ubicacion accesible., tuberia resistente la corrosion salida con flujo equivalente un rociador, codo, rociadores automaticos, conexion de inspector de pruebas, valvula check, conexion del dren principal, presion del agua, conecta tuberia principal, tipico sistema de rociadores humedo, valvula mariposa, urinal wall hung, urinal wall hung, urinal wall hung, wc piece, salida, emergencia, oficinas, gradas, emergencia, planta baja, en dos, edificio de, oficinas, área de devoluciones, parqueo de empleados, area de servicio, de trasportistas, entrada, principal, garita de, control, ramp, cafeteria, patio de maneobras, material, p.o.p., norte, planta de entrepiso, scale:, alineación, municipal, vestidor, hombres, mujeres, rampa montacargas, bad goods, oficinas de, bodega, mantenimiento, carga de, baterias, entra, oficinas, gabinete de manguera, gabinete de manguera, gabinete de manguera, gabinete de manguera, gabinete de manguera, gabinete de manguera, gabinete de manguera, gabinete de manguera, gabinete de manguera, tuberia s.c.i circuito de mangueras, manguera, mangueras, manguera, manguera, manguera, manguera, manguera, manguera, manguera, manguera, manguera, manguera, tanque de agua s.c.i., cuarto de bombas, gpm psi, norte, elevación, sur, elevación, este, elevación, ramp dn, banderas, muro lloron, urinal wall hung, urinal wall hung, urinal wall hung, inspector, test, the area of storage auxiliary, hazard group, type of head, suppression system, designed area of discharge, no. of remote sprinklers, iii, sprinklers, automatic sprinkler system, by hydraulically designed, at base of riser, minimum residual pressure, sprinkler discharge, system demand, gpm, psi, total hose allowance, gpm, total system demand, gpm, basis of design, minimum residual pressure, p.s.i., circuito, the area of storage is protected, hazard group, type of head, suppression system, designed area of discharge, no. of remote sprinklers, mercancia clase ii., sprinklers., automatic sprinkler system, by hydraulically designed, at base of riser, minimum residual pressure, sprinkler discharge, system demand, gpm, psi, total hose allowance, gpm, total system demand, gpm, basis of design, minimum residual pressure, p.s.i., circuito, the area of storage is protected, hazard group, type of head, suppression system, designed area of discharge, no. of remote sprinklers, mercancia clase ii., sprinklers., automatic sprinkler system, by hydraulically designed, at base of riser, minimum residual pressure, sprinkler discharge, system demand, gpm, psi, total hose allowance, gpm, total system demand, gpm, basis of design, minimum residual pressure, p.s.i., circuito, the nestle company is protected, hazard group, type of hose, standpipe and hose system, no. of remote hoses, mercancia clase ii., class ii, standpipe and hose system, by hydraulically designed, at base of riser, minimum residual pressure, hose discharge, system demand, gpm, psi, total system demand, gpm, basis of design, minimum residual pressure, p.s.i., circuito mangueras., the p.o.p. area is protected, hazard group, type of head, control system, designed area of discharge, no. of remote sprinklers, productos miscelaneos., sq. ft., automatic sprinkler system, by hydraulically designed, at base of riser, minimum residual pressure, sprinkler discharge, system demand, gpm, psi, total hose allowance, gpm, total system demand, gpm, basis of design, minimum residual pressure, p.s.i., almacen p.o.p., information sign.

Raw text data extracted from CAD file:

Language English
Drawing Type Detail
Category
Additional Screenshots
File Type dwg
Materials Other
Measurement Units
Footprint Area
Building Features Deck / Patio, Car Parking Lot
Tags , , , , , , , , , , , , , , , ,

ADVERTISEMENT

Leave a Reply

ADVERTISEMENT