Submersible Type Substation DWG Detail for AutoCAD
Detail type submersible electric substation
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
kva, hia, hib, well type high voltage nozzle, high voltage nameplate, elbow support, shunt changer, bayonet fuseholders, nameplate of anticorrosion material, spring type low voltage nozzle, two-position disconnector, stainless steel ground plate, low voltage identification plate, overpressure valve, alumb., circ. from, neutral, neutral, tab., mag contactor., transfer size, neutral, photocell, phase, control diagram, alumb., circ. from, alumb., circ. from, alumb., circ. from, int. gral., of typical lighting, a.p., kva, multiple way connector, amps., kv., transition, fault indicator, typical diagram of average tension, underground, detail of measuring wall control, heel registration, nema, lighting, conduit pipe, polyduct, submersible transformer, kva monophase, public lighting, base of, measurement, wall of, concrete, mts., concrete registration, under floor of cms, in record cfe, kva, front view, rear view, detail of single-phase submersible transformer, leaf section, housing submersible type of network transformation equipment, of underground distribution., use, of being cast in place., on top of this., construction specifications, dimensions in centimeters, the reinforcing steel will be f and kpa, all concrete f’c kpa t.m.a., all the concrete will be made with metered integral waterproofing, according to the product recommendations, all concrete will vibrate to achieve adequate compaction, the coatings will be of minimum cm, the overlaps of rod will be in accordance with the current regulation, the concrete will have finished apparent in the common interior in the exterior not, allowing the use of natural terrain slopes as outer cimbra, only allowed on ground with type III material prior to wetting, all edges will be chamfered mm., cast concrete template poor f’c cm. thick in case, the fillers will adhere to the present specification with degree of compaction, for all layers not greater than cm of, thickness for stream will be of compaction only the last two, layers will be cm thick The lower layers will be cm thick, of compaction proctor., anchors of galvanized mm round steel, for cable lugs on each side opposite the duct bank cm, the copper wire of the ground system must be of cross-section of, awg caliber, all interconnections of ground systems should be, soldering type., for water levels the ground rods must be left out, Inserting Copper Cable from Polyduct Sleeve, when the water level is low the ground rod is installed in the carcamo, the armature will be checked in place., the quality of the materials will be checked by a laboratory authorized by, Through the, first month s, of series name of the marks must be low relief, on any of the inner faces of the register without interferi
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Detail |
Category | Mechanical, Electrical & Plumbing (MEP) |
Additional Screenshots | |
File Type | dwg |
Materials | Concrete, Steel |
Measurement Units | |
Footprint Area | |
Building Features | Car Parking Lot |
Tags | autocad, DETAIL, DWG, éclairage électrique, electric, electric lighting, electricity, elektrische beleuchtung, elektrizität, iluminação elétrica, lichtplanung, lighting project, projet d'éclairage, projeto de ilumina, submersible, substation, type |