Tank Project And Repair Shop DWG Full Project for AutoCAD
Design of structures: Auto Repair, including foundations plane; bracing beams and lightened; plane coverages and trusses; also flat tank structures of materials.
Drawing labels, details, and other text information extracted from the CAD file (Translated from Spanish):
foundation – deposit, project:, design:, revised:, plan:, project manager:, dept. Tacna, Prov. Tacna : tacna, drawing cad :, scale:, date:, sheet number, file:, location: tacna, jla, indicated, ing. joseph linaja ayala, strengthening of the unit of mechanical equipment, ldg, central third splice zone, overburden, foundation corrido, npt, detail foundations corridos, detail of footings, technical specifications, type iv, mortar:, curing, vertical armor splice , lengths of development, diameter, traction, compression, bending, design parameters, masonry confined to yy, -seismic force parameters, -pressure admissible, -screte concrete, -steel, horizontal reinforcement splice, column, beam, rmin. , abutments, hook, standard, end of, -structural system: system contributed in xx, ca, detail columns, xx, sist. contributed, yy, confined masonry, see table of columns, flooring, detail of footings, nfc., foundation, npt, shoe, section xx, typical meeting of beams – floor view, in the middle of the beam, corner, section aa, run, section bb, section cc, section dd, section ee, c ”, beams – deposit, variable, coverage – workshop, intermediate beams – workshop, foundation – workshop, diagonal, fiber cement sheet, lower flange, upper flange, upright, detail: gutter, remains the same, cross type brace, san andrés, gutter, roof and beams workshops, remains the same, truss, detail: support of truss on truss, section a-a ‘, bolt rod with aluminum washer and epdm, the distance between supports will depend on the light given to the plates., profile great wave eternit, longitudinal overlap, lateral overlap, direction of the installation, details of fiber cement sheet and accessories, hook, cross brace type of san andres, typical joist, isometri a of joists, typical detail of tensors, tip., templer, hinged articulated ridge, composed of two pieces. upper and lower. it adapts to any roof inclination., upper, lower, section x-x ‘, uprights, section or-o’, main tijeral detail plant, detail of pit structure, bottom of scuttle, ss-pique cut, concrete pique, see detail of, structure of pit, plant – detail of structure of pit, repair shop, heavy equipment, detail of beams, elevation typical axle dd ee, elevation typical axle dd, roller door, elevation typical axis ai, window, section and -y ‘, head wall, rope wall, reinforced overlay, insulator, neoprene, mobile support detail, j-j’ cut, column, mobile support base plate, fixed support detail, fixed support base plate, k-cut k ‘, detail of intermediate support, intermediate support base plate, l-l’ cut, detail of gusset, welding gusset, note: the joints between, welded tubes, -corrugated iron, -smooth iron, – the whole framework will be painted with special anticorrosive paint two hands on site, this painting process will be applied incl use on the surfaces that will be in, the last hand will be applied once the assembly of the structure is completed., the gussets and plates in general will be cut with a guillotine or saw arch, the holes for bolts will be made with drills and will not be will allow to realize them, the joints in the union with the false beams., beams of edge will be used splices every three meters of length, being located, in bars with lengths of up to six meters, splices will not be accepted in the, to the affection of a maximum use of the materials, it will be accepted until a, for the visual inspection of the welding cords, the following one will be adopted, coated, in the meetings of beams, beams, cartels, plates and profiles, the method of manual electric welding will be used, with electrode fuse, when it is required to carry out tests of the welders, the constructor of the metallic structures in the presence of the supervision and, authorities or companies competent in this type of services and that they employ, by duly qualified welders with certificates granted by, all welding work that must be done by the constructor will be made, experience and qualification of the welder as first category., will present to the supervision the certificates of quality and work, that show the, qualified welders will be employed. the builder of the metal structures, use of qualified welders with certification, contact with joint plates, quality welders., criterion :, in general., welds:, cutting with a blowtorch, torch or punches will not be allowed. , manufacture in workshop :, execution and quality controls for structures, metal :, overlapped, measured, insufficient, a. desirable profiles:, concave, throat, insufficient, c. Unacceptable profiles :, b. acceptable profiles :, the following criterion will be adopted :, excessive, convexity, scour, convex, for the inspection
Raw text data extracted from CAD file:
Language | Spanish |
Drawing Type | Full Project |
Category | Retail |
Additional Screenshots |
|
File Type | dwg |
Materials | Aluminum, Concrete, Masonry, Steel, Other |
Measurement Units | Metric |
Footprint Area | |
Building Features | |
Tags | armazenamento, auto, autocad, barn, beams, bracing, celeiro, comercial, commercial, Design, DWG, foundations, full, grange, including, lightened, plane, Project, repair, scheune, Shop, storage, structures, tank, warehouse |